Manual Empire Products FAW-55IP

20 pages 1.41 mb
Download

Go to site of 20

Summary
  • Empire Products FAW-55IP - page 1

    Installer: Leave this manual with the appli- ance. Consumer: Retain this manual for futur e refer - ence. — Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance. — WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use ...

  • Empire Products FAW-55IP - page 2

    12429-10-0408 Page 2 T ABLE OF CONTENTS INTRODUCTION .................................................................................................................. 3 SAFETY INFORMA TION FOR USERS OF LP-GAS ......................................................... 4 INST ALLA TION ................................................................. ...

  • Empire Products FAW-55IP - page 3

    12429-10-0408 Page 3 Introduction Al w ay s c o ns u lt y o ur lo c al Bu i ld in g D e pa r tm en t r e ga r di n g regulations, codes or ordinances which apply to the installation of a vented wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and ...

  • Empire Products FAW-55IP - page 4

    12429-10-0408 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in ...

  • Empire Products FAW-55IP - page 5

    12429-10-0408 Page 5 V entilation and Combustion Air W all furnaces shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions. In buildings of conventional frame, brick, or stone construction without tight storm windows and doors, infiltration is normal ...

  • Empire Products FAW-55IP - page 6

    12429-10-0408 Page 6 Figure 2 Figure 3 Figur e 3A VENT CENTER TO COMBUSTIBLES MINIMUM CLEARANCE 9/16” (40mm) 4”(102mm) OVAL TYPE “B” CONNECTION 7/1/2” (191mm) MINIMUM CLEARANCE TOP T O COMBUSTIBLES VENT ENCLOSURE DV -651 or DV-665 or DV -666 MINIMUM CLEARANCE TO COMBUSTIBLES 18”(457mm) SIDE OUTLET KIT P ART SOK-1 Register Part SOR- 1 6 ...

  • Empire Products FAW-55IP - page 7

    12429-10-0408 Page 7 Locating Furnace On W all The furnace is to be located on a wall. The furnace is 16 inches (406mm) in width and normal 16 inches (406mm) on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned. A tem plate is pr ovided in furnace c arton for locating gas line conn ection . Also, ref ...

  • Empire Products FAW-55IP - page 8

    12429-10-0408 Page 8 Figure 6 Electrode and pilot must be kept clean. Clean through pilot access hole with a small brush (toothbrush) and water . Proper Main Burner Flame The correct flame will be a short blue inner flame with a much larger light blue outer flame. The main burner (Figure 7) shows the approximate height of each part of the flame ...

  • Empire Products FAW-55IP - page 9

    12429-10-0408 Page 9 V ent Safety Shutoff System This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system. W arning: Operation of this wall furnace when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in ...

  • Empire Products FAW-55IP - page 10

    12429-10-0408 Page 10 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition devi ce which automatically lights the pilot. Do not try to light the pilot by hand. B. BEF ...

  • Empire Products FAW-55IP - page 11

    12429-10-0408 Page 1 1 CALL SER VICEMAN SER VICE AND MAINTENANCE SUGGESTIONS GENERAL: All furnaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation. If the furnace fails to function on initial installation, it is advisable t ...

  • Empire Products FAW-55IP - page 12

    12429-10-0408 Page 12 If the pilot does not light, or the pilot flame current is not at least 1.0 uA and steady , the module will not energize the second main valve and the main burner will not light. Safety Lockout S8600H provides 100 percent shutoff, or safety lockout. A timer starts timing the moment the trial for ignition starts. Ignition spar ...

  • Empire Products FAW-55IP - page 13

    12429-10-0408 Page 13 Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ignition module must be taken within the trial for ignition period. Once the ignition module locks out, the system must be reset by setting the thermostat down for at least one minute before continuing. 3. I ...

  • Empire Products FAW-55IP - page 14

    12429-10-0408 Page 14 S8600H TROUBLESHOOTING GUIDE ...

  • Empire Products FAW-55IP - page 15

    Gr een LED Status Codes Green LED Flash Code (X + Y) a Indicates Next System Action Recommended Service Action OFF No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Normal operation Not applicable None 3 Recycle - Flame failed during run Initiate new trial for ignition. Flash code w ...

  • Empire Products FAW-55IP - page 16

    12429-10-0408 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 WF A-115 Baseplate Gasket 2 1 1763 Outer Casing T op 3 632024 Motor Mount (Four Required) 4 1 1764 Motor Mounting Bar (T wo Required) 5 712059 Gasket (T wo Required) 6 R-619 Motor 7 1 1787 Fan Blade 8 DV -635 Combustion ...

  • Empire Products FAW-55IP - page 17

    12429-10-0408 Page 17 Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62222-0529 P AR TS VIEW ...

  • Empire Products FAW-55IP - page 18

    12429-10-0408 Page 18 Model No. F A W -55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor . Clearance to combustible construction is held by the fixed spacers at 1 inch (25mm) with B-1 vent pipe. Installation must conform to local codes. 4” (102mm) Round (all parts purchase locally except item 2) 1. T ype B- ...

  • Empire Products FAW-55IP - page 19

    12429-10-0408 Page 19 SER VICE NOTES ...

  • Empire Products FAW-55IP - page 20

    12429-10-0408 Page 20 EMPIRE EMPIRE Comfo r t Systems Empire Comfort Systems Inc. 918 Freeburg A ve. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer . www .empirecomfort.com ...

Manufacturer Empire Products Category Furnace

Documents that we receive from a manufacturer of a Empire Products FAW-55IP can be divided into several groups. They are, among others:
- Empire Products technical drawings
- FAW-55IP manuals
- Empire Products product data sheets
- information booklets
- or energy labels Empire Products FAW-55IP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Empire Products FAW-55IP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Empire Products FAW-55IP, service manual, brief instructions and user manuals Empire Products FAW-55IP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Empire Products FAW-55IP.

A complete manual for the device Empire Products FAW-55IP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Empire Products FAW-55IP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Empire Products FAW-55IP.

A complete Empire Products manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Empire Products FAW-55IP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Empire Products FAW-55IP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Empire Products FAW-55IP, that we can find in the current document
3. Tips how to use the basic functions of the device Empire Products FAW-55IP - which should help us in our first steps of using Empire Products FAW-55IP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Empire Products FAW-55IP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Empire Products FAW-55IP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Empire Products FAW-55IP?

Use the form below

If you did not solve your problem by using a manual Empire Products FAW-55IP, ask a question using the form below. If a user had a similar problem with Empire Products FAW-55IP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)