  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 1

    Operators Manual Installation, Operation & Service Gas Floor Model Kettles MODELS : Stationary - KGL-40, KGL-60, KGL-80, KGL-100 Tilting - KGL-40-T , KGL-60-T , KGL-80-T Short Series - KGL-40-SH, KGL-60-SH, KGL-40-TSH KGL-40 KGL-40-T KGL-40SH SE95003-1 Rev . 1 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: ( ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 2

    FOR THE USER W ARNING : Improper installation, adjustment, alteration, ser vice or maintenance can cause proper ty damage, injury or death. Read the installation operating and maintenance instructions thoroughly bef ore installing or ser vicing this equipment. FOR YOUR SAFETY DO NO T ST ORE OR USE GASOLINE OR ANY O THER FLAMMABLE LIQUIDS AND V APOU ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 3

    T ABLE OF CONTENTS Installation Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 V entilation . . . . . ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 4

    1 INSPECTION Before unpacking visually inspect the unit for evidence of damage during shipping. If damage is noticed, do not unpack the unit, follow shipping damage instructions. SHIPPING DAMAGE INSTRUCTIONS If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim. 1. Write dow ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 5

    2 ELECTRICAL ENSURE THE ELECTRICAL SUPPL Y MA TCHES THE KETTLE'S REQUIREMENTS AS ST A TED ON THE RA TING LABEL. A cord and plug ar e supplied with the unit. Simply plug the unit into any grounded outlet rated for a minimum of 10 amps. The wiring diagram is located on the back of the console access panel. W ARNING: Electrical Grounding Instruct ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 6

    3 Specification Drawing - Stationary , KGL-40, KGL-60, KGL-80, KGL-100 NO TES : Clev eland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the o wner and installer to comply with the codes. Installation of backflow pre venters, v acuum breakers and ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 7

    4 Specification Drawing - Tilting, KGL-40-T , KGL-60-T , KGL-80-T NO TES : Clev eland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the o wner and installer to comply with the codes. Installation of backflow pre venters, v acuum breakers and other ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 8

    5 Specification Drawing - Short Series, KGL-40-SH, KGL-60-SH, NO TES : Clev eland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the o wner and installer to comply with the codes. Installation of backflow pre venters, v acuum breakers and other spe ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 9

    6 Specification Drawing - Short Series, KGL-40-TSH SPECIFICA TIONS NOTES FOO T LOCA TION & FLOOR DRAIN DET AIL FLANGED FOO T DET AIL 9/16" 14 mm 120º TYP 1" (25 mm) MAX. ADJUSTMENT 1 5/8" (42 mm) Ø 7/16" (11 mm) Ø 3 HOLES ON 3 1/8" (80 mm) Ø B.C.D. 4 7/8" 124 Ø mm NO TES : Clev eland Range reserves right of de ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 10

    7 OPERA TING INSTRUCTIONS 3 4 5 2 1 7 5 8 10 9 6 ITEM # DESCRIPTION FUNCTION 1. Low W ater Indicator Light (Red) When lit, indicates that the kettle is low on water and will not operate in this condition (see RESERVOIR FILL PROCEDURES on page #28. 2. On-Off Switch/ T urns kettle ON/OFF and allows the operator to adjust the kettle Solid State temper ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 11

    8 OPERA TING THE KETTLE DO NO T A TTEMPT T O OPERA TE THIS APPLIANCE DURING A PO WER F AILURE. KEEP APPLIANCE AND AREA FREE AND CLEAR OF COMBUSTIBLES. DO NO T LEAN ON OR PLA CE OBJECTS ON KETTLE LIP . SERIOUS INJUR Y COULD RESUL T IF KETTLE TIPPED O VER, SPILLING HOT CONTENTS. IF Y OU ARE COOKING AN EGG OR MILK PRODUCT , DO NO T PRE-HEA T KETTLE. 1 ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 12

    9 CARE AND CLEANING Y our kettle must be cleaned regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, r eliable operation. W ARNING: Do not use chloride base detergents. There is a gr owing number of non-chloride cleaners available. If unsure of the cleaners chlorine content consult the supplier . Also av ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 13

    10 WRAP COVERS TO P LEFT SIDE FRONT RIGHT SIDE BACK KETTLE T OP FRONT LEFT SIDE RIGHT SIDE B A CK KGL-40 KE01479 -X KE53483-4 KE54253 -X KE01432 -X KE02186-1 KGL-60 KE01479-1 KE53483-5 KE54253-1 KE01432-1 KE02186-2 KGL-80 KE01479-2 KE53483-6 KE54253-2 KE01432-2 KE02186-3 KGL-100 KE01479-3 KE53483-7 KE54253-3 KE01432-3 KE02186-4 KGL-40-T KE01479 -X ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 14

    11 PRESSURE RELIEF ASSEMBL Y 6 5 4 2 3 8 7 ITEM NO . P ART NO . DESCRIPTION QTY . PRESSURE RELIEF V AL VE ASSEMBLIES 1. KE01450 FOR ASME KETTLES (INCLUDES #2-6) 1 KE01450-1 FOR CE KETTLES (INCLUDES #2-6) 1 2. F A05049 MALE CONNECTOR, 1/2" PIPE - 1/4" TUBE 1 3. FI00151 STREET ELBOW , 90°, 1/2", BRASS 2 4. FI00178 TEE, 1/2" FPT , ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 15

    12 HINGE ASSEMBL Y 1 5 3 2 13 12 6 4 7 11 8 10 9 9 ITEM NO . P AR T NO . DESCRIPTION QTY . 1. - 11 SE00120-1 HINGE ASSEMBL Y - KGL-40/T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SE00120-2 KGL-60/T , KGL-80/T , KGL-40-T/SH . . . . . . . . . . . . . . . .1 SE00120-3 KGL-100/T , KGL-60-T/SH . . . . . . . . . . . . . . . ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 16

    13 ELECTRICAL COMPONENT BOX ITEM ON. P ART NO . DESCRIPTION QTY . KE01422 ELECTRICAL CONTROL BOX ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53439 COMPONENT BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53440 COVER, COMPONENT BOX . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 17

    14 3 4 5 6 2 For the following units with covers KGL-40-T KGL-60-T KGL-80-T For the following units with or with-out covers KGL-40-TSH For the following units with-out covers KGL-40 KGL-80 KGL-40-SH KGL-60 KGL-100 KGL-60-SH 1 TRUNNION ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. KE00354 TRUNNION BEARING ASSEMBL Y . . . . . .1 2. KE00351 TRUN ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 18

    15 GAS CONTROL ASSEMBL Y 1 16 17 18 19 20 21 31 32 33 34 22 23 24 8 9 10 2 3 30 35 29 4 5 6 4 7 11 13 14 12 15 25 25 26 27 22 28 28 29 30 Stationary Models Tilting Models 34 Air Blower Primary Air Orifice Secondary Air Orifice Gas Orifice Ignitor Burner Gas Valve Shut-Off Valve ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 19

    16 GAS CONTROL ASSEMBL Y ITEM ON. P ART NO . DESCRIPTION QTY . 1. KE53441 BLOWER, 115V , 60 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53441-1 BLOWER, 220V , 50 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE54420 AIR INT AKE W ASHER ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 20

    17 GEARBOX ASSEMBL Y 40 41 25 42 26 27 28 39 4 5 6 5 7 5 6 5 4 8 25 15 14 1 10 2 3 9 11 12 13 16 17 18 19 20 21 22 32 30 32 31 24 23 24 23 36 34 33 35 37 38 ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 21

    18 GEARBOX ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE52836-2 TIL T SHAFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE50315 WORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. F A95005 TENSION PIN . . . . . . . . . . . . . . . ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 22

    19 CONSOLE CONTROLS ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50504 SWITCH, TOGGLE (USED PRIOR TO JANUARY 2000) . . . . . . . . . . . . . . . . . . .1 2. SK50062 RUBBER BOOT (USED PRIOR TO JANUARY 2000) . . . . . . . . . . . . . . . . . . . . .1 3. SE00114 POTENTIOMETER WITH ON/OFF SWITCH, C/W ITEM #4 . . . . . . . . . . . . . . . . .1 KE50988-2 ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 23

    20 MAINTENANCE INSPECTION AND MAINTENANCE CHECKLIST Cleveland Range equipment requir es little preventative maintenance. W e do however pr ovide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%. INSPECTION AND MAINTENANCE CHECKLIST The following check s should be completed eve r y six months or ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 24

    21 KETTLE SAFETY INSPECTION CHECKLIST Regular inspection and maintenance of units is essential to obtain trouble fr ee and safe operation of equipment. Inspections must include testing of the pressur e relief valve and checks of the operating system to insure that it has not been alter ed. No safety features designed into the equipment should ever ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 25

    22 SAFETY THERMOST A T : ✘ Probe removed partially ✘ Probe removed completely ✘ Thermostat electrically bypassed ✔ Probe fully inserted in tube Wiring is properly connected 12 3 Incorrect Installations 1 Safety thermostat probe is not completely inserted into tubing. 2 Safety thermostat probe is r emoved from tubing. 3 Safety thermostat ele ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 26

    23 GENERAL 1. T o tur n the unit on, turn the switch to the on position. ■ Power is sent to primary side of the 120vac/16vac transformer . ■ Power is sent to the normally closed high limit. ■ From the high limit power is sent to the normally open contacts of the 12VDC relay and the L1 and L2 terminals of the ignition module. 2. From the secon ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 27

    24 TROUBLESHOOTING GUIDES (continued) PROBLEM: KGL Kettle Won't Heat Does red light come on when unit is first turned on? Does red light go off shortly after unit is turned on? Yes Add water to jacket of Kettle. With the potentiometer set at 10, is 12 VDC at the coil of the relay? No Yes Is 16 VAC measured across Pins 9 and 10 on the controlle ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 28

    25 TROUBLESHOOTING GUIDES (continued) PROBLEM: KGL Kettle Not Hot Enough With kettle pot empty and temperature knob set at 10, is the temperature of the surface of the pot 260 degrees? Unit is operating properly Yes When unit is cold (room temp) is the pressure gauge in the green? No Vent the kettle per instructions in the manual. No When the unit ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 29

    26 TROUBLESHOOTING GUIDES (continued) PROBLEM: KGL Kettle Gets Too Hot With the kettle empty and the temperature set at 10, is the surface temp 260-265 degrees? The kettle is working properly. Yes Does the kettle continue to call for heat (green light stays on) when the kettle reaches 260-265 degrees? No Is there supply voltage to the coil of the g ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 30

    KETTLE VENTING INSTRUCTIONS 1. Remove Access Panel from back of main kettle console. 2. T urn kettle ON and set temperature control to 10 , heat the empty kettle until unit cycles off. 3. V ent kettle by pulling V alve Ring eight to fifteen times, holding valve open for two seconds each time. NOTE : If unit cycles ON, stop venting and wait for kett ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 31

    RESERVOIR FILL PROCEDURES The kettle's water level must be maintained at the proper level. Under normal operating conditions, the sealed water reservoir should never r equire the addition of water . If the red "low water" light comes on during use (while the kettle is in an upright position), the water level has reached a critically ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 32

    29 PRESSURE RELIEF V AL VE PERIODIC TESTING Most insurance agencies requir e periodic testing of pressur e relief valves used on pr essure vessels. This procedur e will allow you to safely and quickly test your kettle's pressur e relief valve. W e recommend this test be perfor med twice a year . NOTE: The following instruction is intended for ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 33

    3. Remove Console Cover and Access Panel. 4. Pull Pressur e Relief V alve Ring open to insur e vessel is not pressurized. 5. Remove 1/4" copper tubing and reducer bushing. 6. Remove Drain Plug cap and allow water to drain. 7. Replace Drain Plug cap and add water until it shows on sight glass. 8. Repeat steps 6 & 7 until water drains clear ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 34

    31 GAS KETTLE ORIFICE REPLACEMENT Gas Orifice Console Cover "O" Ring Spring Plug 1. Remove Console Cover 2. Remove Plug and Spring 3. Remove Orifice 4. Replace with new Orifice and "O" ring 5. Replace Spring and Plug 6. Replace Console Cover Kettles BTU's per Gas W ater # of Hour T ype Column Orifices KGL-40, 140000 Natural ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 35

    32 NOTE: Use thread sealant compatible with pr opane gas on all threaded piping connections. 1. Disconnect electrical connection. 2. Shut off main gas supply and disconnect kettle fr om supply line. 3. Remove main kettle CONSOLE CO VER . 4. Remove PLUG and SPRING . 5. Remove GAS ORIFICE and “O” RING . 6. Replace first with new “O” RING and ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 36

    33 WIRING DIAGRAMS Diagram #1 : Floor Gas K ettle (except KGL-25/T) 110-120 V olts, 60Hz 1 2 3 4 5 7 13 14 15 17 18 19 20 16 6 9 11 10 8 KE90407-E ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 37

    34 Diagram #1 (continued): Floor Gas K ettle (except KGL-25/T) 110-120 V olts, 60Hz ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE55069-6 SAFETY THERMOST A T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2 KE53436 AIR PRESSURE SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 38

    35 Diagram #2 (see Diagram #1 f or common par ts): Floor Gas K ettle (except KGL-25/T) 200-240 V olts, 60Hz ITEM NO . P ART NO . DESCRIPTION QTY . 21 KE53838-2 TRANSFORMER 120-24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 22 KE53441 BLOWER, 115V , 60 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 39

    36 Diagram #3 (see Diagram #1 f or common par ts): Floor Gas K ettle (except KGL-25/T) 200-240 V olts, 50Hz ITEM NO . P ART NO . DESCRIPTION QTY . 23 KE53441-1 BLOWER, 220V , 50 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 24 KE53838-2 TRANSFORMER 120-24V . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 40

    37 ON MARCHE ENCENDIDO ACCESO AN P AUSE, INTERRUPTION P AUSE, INTERRUPTION P AUSA, INTERRUPCION P AUSA, INTERRUZIONE P AUSE, UNTERBRECHUNG RESET RÉENCLENCHER RECONECT AR RESET NULLSTELLEN STOP OF ACTION ARRÊT DE L'ACTION P ARAR FUNCIONAMIENTO ARRESTO OPERAZIONE FUNKTION STOPPEN F AST STOP , EMERGENCY ARRÊT RAPIDE D'URGENCE P ARADA RAPI ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 41

    38 LOW W A TER NIVEAU BAS DE L'EAU NIVEL DE AGUA BAJO LIVELLO BASSO W ASSERST AND NIEDRIG IGNITION F AILURE P ANNE D'ALLUMAGE F ALLO DE ENCENDIDO MANCA T A ACCENSIONE ZÜNDUNGSFEHLER COOLING REFROIDISSEMENT REFRIGERACION RAFFREDDAMENTO KÜHLUNG MIXER BRIDGE PONT DU MÉLANGEUR PUENTE DE MEZCLADORA MENSOLA MESCOLA TORE MISCHER-BRÜCKE RIGHT ...

  • Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - page 42

    SP ARE P ARTS LIST The following is a spare parts listing of parts that wear during nor mal us or are apt to be misplaced during normal operation. These par ts should be kept on hand to prevent loss time due to a minor problem. P ART NUMBER DESCRIPTION QUANTITY KE00458 KETTLE SOLID ST A TE CONTROL BOX . . . . . . . . . . . . . . . . . . . . . . . . ...

Manufacturer Cleveland Range Category Hot Beverage Maker

Documents that we receive from a manufacturer of a Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH can be divided into several groups. They are, among others:
- Cleveland Range technical drawings
- KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH manuals
- Cleveland Range product data sheets
- information booklets
- or energy labels Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, service manual, brief instructions and user manuals Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH.

A complete manual for the device Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH.

A complete Cleveland Range manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, that we can find in the current document
3. Tips how to use the basic functions of the device Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH - which should help us in our first steps of using Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH?

Use the form below

If you did not solve your problem by using a manual Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, ask a question using the form below. If a user had a similar problem with Cleveland Range KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)