    Monarch ® , 9825 ® , 9855 ® , and 9860 ® are tradem arks of Paxar Americas, Inc. Avery Denn ison ® is a trademark of Avery Dennison Corp. DataBar is a trademark of GS1. Portions of this software are © 2007 The FreeT ype Project (www.freetype.org). All rights reserved. TC9855PMAD2 Rev. AB 4/08 © 2008 Avery Dennison Corp. All rights reserved. ...

  • Avery 9825 - page 2

    2 Defining a GS1 DataBar ™ (RSS) Symbology The GS1 DataBa r is a family of linear symb ologies. De pending on the bar code data en tered, th e bar code may appear as a 2D bar code stacked on top of the linea r bar code. For more in formatio n about the GS 1 DataBar ba r code, refe r to the GS1 Ge neral Speci fication . Syntax B,field#,# of char,f ...

  • Avery 9825 - page 3

    3 Left-Justified Fields Row B4. fix/var Fixed ( F ) or variab le ( V ) length field. B5. row Distan ce from bott om of the print area to the pivot poi nt of the fiel d. The pivot poin t varies, depending on ho w the field is justified . To easily identify the pivot points (ma rked with a circle), a linear bar code is show n: Printer Unit of Measure ...

  • Avery 9825 - page 4

    4 B8. density Bar code densi ty. The range is 2-8. The default is 2 . Select the density from the following table. Bar Code Type Density Selector 203 dpi Narrow Element Size (dots/mils) 300 dpi Narrow Element Size (dots/mils) Data Length Char Set 2 2/9.9 3/9.8 3 3/14.8 4/13.1 4 4/19.7 5/16.4 5 5/24.6 7/23 6 6/29.6 8/26.2 7 7/34.5 10/32.8 GS1 DataBa ...

  • Avery 9825 - page 5

    5 B13. type Select from th e bar code family . Options: 1 GS1 Da taBar 1 4 2 GS1 Da taBar 14 Truncated 3 GS1 DataB ar 14 Stac ked 4 GS1 Da taBar 14 Stacked Omni d irectional 5 GS1 Da taBar L imited 6 GS1 DataBar Expanded 7 UPCA 8 UPCE 9 EAN13 10 EAN8 11 UCC/EAN128 and CC A/B 12 UCC/EAN128 and CC C B14. sep_height Height of the separator between the ...

  • Avery 9825 - page 6

    6 Defining the RFI D Setup Packet for UH F (9855 only) Use the RF ID setup p acket (X) to set the pro tocol, write att empts, re ad power, write po wer, and signal adjus t. Note: Refer to the RFID Setup G uide and S upply Char t for the read and write power settin gs and sign al adjustme nt based on your RFID supplies. Syntax {I,X,protoc ol,write _ ...

  • Avery 9825 - page 7

    7 Defining the RFID Setup Pa cket for HF (9855 only) Use the RFID setu p packet (X) to set the protoco l, write attempt s and attenuatio n. Note: Refer to the HF Setup Gu ide and Supply Chart for the prot ocol and attenuation settings based on your RFID supplies . Syntax {I,X,protoc ol,write _attem,att enuation ¦} X1. X RFID Setup Packet X2. prot ...

  • Avery 9825 - page 8

    8 Using Internatio nal Fonts Version 6.0 or greate r (9855/98 60) and versi on 3.0 or greater (9825 ) have a new font rasterizer, which allows for an addition al symbol s et (110 – Unicode UT F-8). To use this symbo l set, you must downlo ad an Internationa l TrueType font. An Inte rnational TrueType font conta ining Chinese or Japanese ch aracte ...

  • Avery 9825 - page 9

    9 The printe r automati cally translates som e character mappings to othe rs. For example, if you need a BIG 5 font, it is possible to use Unicod e text da ta. Use Unicode in the symbo l set parameter to indica te the text mappin g and select the BIG5 font needed in the font pa rameter (T8 or C5). The printer automatica lly translates th e Unicode ...

  • Avery 9825 - page 10

    10 In text (T15) an d constant text (C1 3) fields, symbol set 110 (Unic ode UTF-8) is available. T15. sym set Symbol set. Op tions: 0 Internal Sy mbol Set 1 ANSI Symbol Set 100 Macintosh 101 Wingdings 102 Unicode (user input) for particul ar mapping 103 BIG5 (use r input) for Uni code mapping* 104 GB2312 (user inpu t) for Unicode mapping* 105 SJIS ...

  • Avery 9825 - page 11

    11 Setting the Numeric Format Use the new menu item in the Setup, Defa ults menu to select h ow numeric values appear in your printed data. With symbol set 110 (Uni code UTF-8), data sent to the pr inter can be in mixed format (Latin a nd Arabic cha racters). The choices inclu de Default, Arabic-I ndic, and East ern Arabic. Default Latin numera ls ...

  • Avery 9825 - page 12

    12 To change the set ting, from the Main Menu, s elect Setup, then Defaults. Then, follow the se steps. 1. Press » or ¼ until you see DEFA ULTS » Numeric Format ¼ 2. Press Enter/Pause . The current set ting is dis played, fo r example: NUMERIC FORMAT Default ¼ 3. Press » or ¼ until you see the optio n you want. Then press Enter/Pause . Press ...

  • Avery 9825 - page 13

    13 The following labe l prints with Arabic- Indic set fo r the Numeric Format: Viewing the Serial Num ber (9825 only) The printer's seria l number can be vie wed by accessing the Di agnostics menu. Pre ss Feed/C ut three times and then pres s Enter/Pause . 1. From the Diagnos tics menu, pre ss » or ¼ until y ou se e DIAGNOSTICS Version ¼ 2. ...

  • Avery 9825 - page 14

    14 ...

Manufacturer Avery Category Photo Printer

Documents that we receive from a manufacturer of a Avery 9825 can be divided into several groups. They are, among others:
- Avery technical drawings
- 9825 manuals
- Avery product data sheets
- information booklets
- or energy labels Avery 9825
All of them are important, but the most important information from the point of view of use of the device are in the user manual Avery 9825.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Avery 9825, service manual, brief instructions and user manuals Avery 9825. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Avery 9825.

Similar manuals

A complete manual for the device Avery 9825, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Avery 9825 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Avery 9825.

A complete Avery manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Avery 9825 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Avery 9825, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Avery 9825, that we can find in the current document
3. Tips how to use the basic functions of the device Avery 9825 - which should help us in our first steps of using Avery 9825
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Avery 9825
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Avery 9825 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Avery 9825?

Use the form below

If you did not solve your problem by using a manual Avery 9825, ask a question using the form below. If a user had a similar problem with Avery 9825 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)