    Subject to technical changes OPERA TING INSTRUCTIONS BECKER AR 4201 - ( O) (GK 415) portable VHF Transceiver B e c k e r F l u g f u n k w e r k G m b H B a d e n A i r p a r k , B 1 0 8 D - 7 7 8 3 6 R h e i n m ü n s t e r ( G e r m a n y ) T e l . + 4 9 ( 0 ) 7 2 2 9 / 3 0 5 - 0 F a x + 4 9 ( 0 ) 7 2 2 9 / 3 0 5 - 2 1 7 E - M a i l i n f o @ b ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 2

    © Copyright by Becker Flugfunkwerk Issue 05/00 Article No. 890.375-071 ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 3

    Blank Operating Instructions Page 40 Issue 05/2000 Table of contents Important 3 Introduction 3 Safety information 4 Additional information 5 General information 6 Controls and indicators 7 p Switching on the unit 8 Function of controls and indicators 9 Operating instructions 8 p Switching on the portable VHF station 1 1 p T ransmit/receive mode 12 ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 4

    p Setting the IC level 24 p Calibrating the temperature sensor 24 p Setting addressable storage locations 1 to 99 24 p Setting the temperature display in °C or °F 25 p Switching on the scan function 25 p Setting the hold time in the scan function 25 p Inhibiting the frequency setting (channel selection only) 26 p Inhibiting the frequency storage ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 5

    Operating Instructions Page 38 Issue 05/2000 Important Carefully read these operating instructions right through before attemp - ting to operate the portable VHF station. Keep these operating instructions carefully. They contain important sa - fety and operating instructions for the portable VHF station. Introduction Thank you for purchasing the BE ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 6

    The CAUTION, WARNING and NOTE highlights have the following meanings: Failure to comply, or incorrect compliance, with these instructions or procedures can lead to in - juries or fatal accidents. Failure to comply, or incorrect compliance, with these instructions or procedures can lead to damage to equipment. NOTE Feature to which attention should ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 7

    Operating Instructions Page 36 Issue 05/2000 Additional information l A speech test is to be performed before startup and it should be no - ted that if the speech test is carried out close to the portable VHF sta - tion the results may be positive even if the antenna cable is broken or short-circuited. At a distance of 5 to 10 km no connection will ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 8

    General information Carrying case and transceiver together form a portable VHF station. The easily-portable VHF station can be used, for example, for mobile and fi - xed operations on airfields or landing strips. It an also be used in hot air balloons, for ferrying aircraft or or recovery of gliders. The carrying case contains the battery , speaker ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 9

    Servicing and operation of lead-acid batteries Lead-acid batteries are to be charged immediately after use. Disch - arged lead-acid batteries are to be charged for approximately 16 hours at 1/10 of the rated capacity. A few basic rules need to be observed in the handling of lead-acid batte - ries, to maintain their service life over several years. ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 10

    Operating instructions Connect the antenna and the mike to the corresponding connection jacks. o Switching on the unit Switch on the portable VHF station using the ON/OFF switch (rotate vo - lume control clockwise). The battery charger shall be operated at a distanced of at least 50 cm (maximum cable lengt) from the portable VHF-Transceiver, to avo ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 11

    T echnical data Supply voltage range 10 V . . . 32 V DC Normal power supply voltage 13.75 V DC Power consumption at 13.75 V - “Standby” reception mode typ. 70mA - Reception mode typ. 500mA - T ransmission mode typ. 2,5 A T emperature range - 20° C . . .+ 55° C Dimensions (H x W x D) 270 x 1 15 x 80 mm Weigth 3.5 kg Frequency range 1 18.000 .. ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 12

    CH 99 (bottom line) Indicates the storage channel CH indication flashes If the initiated storage operation (bottom line) is not completed by pressing the store key F (bottom line) Indication that the selected storage channel is not occupied V 1 1.7 (bottom line) Indication of supply voltage All indicating segment Supply voltage £ 10.5 V flashes CS ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 13

    o Channel priority ON/OFF switch (option upwarts serial no.: 46) Call up function SF 18 using the MDE key . The following displays appe - ars : T op line SF 18 Bottom line CS channel number Using the kHz (steps of 1) or MHz (steps of 10) switch, select the de - sired channel. Store the channel by pressing the STO key . Several channels can be selec ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 14

    o T ransmit/receive mode Set the frequency in the preset display and press the exchange key . Ro - tate the VOL control to the centre position. Operate the transmit button and call the other station. Hold the micro - phone close to the lips for optimum speech transmission. NOTES l The triangle in the top line of the display indicates transmit mode. ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 15

    o Setting the “channel end” scanning range (if funtion SF8 ac - tivated) Call up function SF 14 using the MDE key . The following displays appe - ar : T op line SF 14 Bottom line CS channel number Using the kHz (steps of 1) or MHz (steps of 10) switch, select the end channel at which the scan function is to stop. Store the end channel by pressi ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 16

    o Flashing of the LCD If the power supply for the portable VHF station drops below 10.5 V , the display begins to flash. This flashing indicates, when operating on batte - ries for example, that the batteries require recharging. In prac-tice the display begins to flash in the transmit mode because this is when the po - wer consumption is greatest. ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 17

    o Inhibiting the frequency setting (channel selection only) Call up function SF 10 using the MDE key . The following displays appe - ar : T op line SF 10 Bottom line 0 or 1 Select the required function using the kHz key and store the function by pressing the STO key . 0 = Frequency setting not possible. The VHF station can only work on the frequenc ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 18

    o Mode 1 (standard mode) The last displayed active and preset frequencies appear in the LCD dis - play . The preset frequency (bottom line) is set using the MHz and kHz fre - quency selector switches. When the exchange key is pressed, a change from the active to the pre - set frequency occurs. A further operation of the key cancels the frequen - cy ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 19

    o Setting the IC level Call up the SF4 function using the MDE key . The following displays ap - pear : T op line SF 4 Bottom line 00 to 63 The IC level can be changed upwards or downwards using the kHz switch. The set value is stored by pressing the STO key . o Calibrating the temperature sensor Not activated in the portable VHF station. SF5 is not ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 20

    o Scan function If the scan function is activated in the equipment configuration, pressing the STO key changes from the channel selection mode to the scan function. In the scan function, the frequency appears in the top line of the display and the associated channel with the preset CS is shown in the bottom line. In the scan function, either all th ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 21

    l In the service mode the portable VHF station operates indepen - dent-ly of the settings on the control panel, on the frequency which was last set as the active frequency . Wenn the PTT-Key is pressed in the service mode, the display indicates in the top line the active frequency l The user can interlock his equipment configuration settings with t ...

  • Becker Designed AR 4201 - ( O) (GK 415) - page 22

    Service mode (equipment configurations) The service mode is meant to enable to set the equipment configuration. The following settings can be changed or set : SF 1 Setting the switch-on threshold of the squelch SF 2 Setting the sidetone volume SF 3 Setting the AF auxiliary volume SF 4 Setting the IC volume SF 5 Calibrating the temperature sensor (N ...

Manufacturer Becker Designed Category Marine Radio

Documents that we receive from a manufacturer of a Becker Designed AR 4201 - ( O) (GK 415) can be divided into several groups. They are, among others:
- Becker Designed technical drawings
- AR 4201 - ( O) (GK 415) manuals
- Becker Designed product data sheets
- information booklets
- or energy labels Becker Designed AR 4201 - ( O) (GK 415)
All of them are important, but the most important information from the point of view of use of the device are in the user manual Becker Designed AR 4201 - ( O) (GK 415).

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Becker Designed AR 4201 - ( O) (GK 415), service manual, brief instructions and user manuals Becker Designed AR 4201 - ( O) (GK 415). Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Becker Designed AR 4201 - ( O) (GK 415).

A complete manual for the device Becker Designed AR 4201 - ( O) (GK 415), how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Becker Designed AR 4201 - ( O) (GK 415) by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Becker Designed AR 4201 - ( O) (GK 415).

A complete Becker Designed manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Becker Designed AR 4201 - ( O) (GK 415) - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Becker Designed AR 4201 - ( O) (GK 415), FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Becker Designed AR 4201 - ( O) (GK 415), that we can find in the current document
3. Tips how to use the basic functions of the device Becker Designed AR 4201 - ( O) (GK 415) - which should help us in our first steps of using Becker Designed AR 4201 - ( O) (GK 415)
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Becker Designed AR 4201 - ( O) (GK 415)
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Becker Designed AR 4201 - ( O) (GK 415) in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Becker Designed AR 4201 - ( O) (GK 415)?

Use the form below

If you did not solve your problem by using a manual Becker Designed AR 4201 - ( O) (GK 415), ask a question using the form below. If a user had a similar problem with Becker Designed AR 4201 - ( O) (GK 415) it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)