Manual Patton electronic 2094

20 pages 0.38 mb
Download

Go to site of 20

Summary
  • Patton electronic 2094 - page 1

    USER MANUAL MODEL 2094 V .35 to E1/Fractional E1 Converter SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com P ar t# 07M2094-UM Doc# 08605U2-004, Re v . B Re vised 10/25/06 An ISO-9001 Certified Company Notes __________________________________________ __________________________________________ _____________________ ...

  • Patton electronic 2094 - page 2

    P A TTON MODEL 2094 T ABLE OF CONTENTS Section Page 1.0 General Information ...............................................................2 1.1 W arranty Statement 1.2 Radio and TV Interference 1.3 CE Notice 1.4 Service Information 2.0 General Information ............................................................5 2.1 Features 2.2 General Produc ...

  • Patton electronic 2094 - page 3

    1.4 SERVICE INFORMA TION All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Support at: tel: (301) 975-1007 ; email: support@pa ...

  • Patton electronic 2094 - page 4

    2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed for One Y ear parts and labor . If any questions arise during installa- tion or use of the unit, contact Patton Electronics T echnical Services at (301) 975-1007. 2.1 FEA TURES • T ermin ...

  • Patton electronic 2094 - page 5

    Switch SW1: Line Coding Use Switch SW1 to control the Network Line Coding options. Set these options to be the same as the Line Coding given to you by your Service Provider . If you are using two Model 2094s together as short range modems, set both units to HDB3. SW4 Line Framing & Coding Off HDB3 On AMI Line Coding Options: High Density Bipola ...

  • Patton electronic 2094 - page 6

    CLOCK MODES Network Clock T ransmitter timing is derived from the received line signal. Internal Clock T ransmitter clock is derived from an internal clock source. External Clock T ransmitter timing is derived from the local DTE device. V alid only in unframed mode. Note: When using the 2094 as a high-speed short range modem, one unit of the link m ...

  • Patton electronic 2094 - page 7

    NOTE: When the data rate is set to 2.048Mb/s, then the unit is forced into G.703 mode, and it transmits user data on all 32 times- lots. There is no framing information; therefore, the CAS MF (SW2) switch is ignored. SW3 is defaulted to clock mode. In all other rate settings, the unit employs G.704 framing; TS0 is reserved for signaling. 3.2 SOFTW ...

  • Patton electronic 2094 - page 8

    3.2.1 Introduction to Main Menu After entering the password, you may access all of the system’s functions and parameters. The Main Menu looks like this: HELPFUL HINTS 1. T o make a selection, key the highlighted letter that corre- sponds to a menu selection. 2. T o execute the selection, type [Enter/CR] 3. Select g Save Changes from Main Menu aft ...

  • Patton electronic 2094 - page 9

    3.2.2 System Configuration The System Configuration menu looks like this: The System Configuration options are described below: Line Format: G.703 (default) Options: G.703, G.704 G.703: G.703 is unframed, 2.048Mb/s. In this case, the DTE rate is equal to the line rate at the network interface (NI). CAS MF and CRC-4 are disabled. G.704: G.704 reserv ...

  • Patton electronic 2094 - page 10

    Clocking : Network (default) Options: Network, Internal, External Network: This is the most commonly used setting when connect- ing to a carrier ’s network. In this mode, the unit recovers the clock from the received signal and uses it to transmit data. In this way the unit remains synchronized to a master clock. In campus applications, one of th ...

  • Patton electronic 2094 - page 11

    3.2.3 System Diagnostics The System Diagnostics/Statistics screen looks like this: NOTE: This screen is updated once per second. The System Diagnostics/Statistics options and functions are described below . Local Loop Idle (default) The Local Loop is a bi-lateral loopback in which the data from the local DTE and the data from the remote unit are lo ...

  • Patton electronic 2094 - page 12

    22 21 Remote Loop Idle (default) The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 2094s, as well as the communica- tion link between them. Data from the local DTE is sent across the entire communication circuit and looped back to the local DTE. The Model 2094 Initiating a RDL can be in one of the foll ...

  • Patton electronic 2094 - page 13

    23 24 Use this option to select the test pattern used to test the link. NI ST A TUS The Network interface (NI) status is shown in the middle of the Diagnostics/Statistics screen. The brackets are empty when the link is operating normally . Only one error message is provided Receiver Carrier Loss [RCL] occurs when 255 consecutive zeros have been det ...

  • Patton electronic 2094 - page 14

    25 26 Loop Timeout The Loop T imeout setting can be set to one of the following: 00:05 = five minutes 00:10 = ten minutes 00:15 = fifteen minutes 00:30 = thirty minutes (default setting) 00:45 = forty-five minutes 01:00 = one hour 01:30 = 90 minutes 02:00 = two hours 03:00 = three hours NEVER = forever—the unit will remain in loopback without use ...

  • Patton electronic 2094 - page 15

    27 28 4.3 POWER CONNECTION The Model 2094 offers three ways to supply external power: AC power , DC power and interface power . 4.3.1 Using the AC Power Supply (100-240V AC) The Model 2094 uses a 5VDC, 2A universal input 100-240V AC, power supply (center pin is +5V). The universal input power supply is equipped with a male IEC-320 power entry conne ...

  • Patton electronic 2094 - page 16

    29 30 LOS The Loss of Sync LED lights when the unit loses synchronization with the incoming sig- nal. This may happen when there is a fram- ing mismatch or a loss of signal. In unframed mode, the LOS LED monitors the status of the transmit clock. ALM The alarm LED indicates the presence of a AIS or RAI, or Out of Frame condition. The ALM LED will b ...

  • Patton electronic 2094 - page 17

    31 32 T o perform an RDL test, follow these steps: 1. Activate RDL. This may be done in two ways: a. Enter Remote Loop from the System Diagnostics/Statistics menu and toggle the <Spacebar> until “TM” appears next to the Remote Loop option.; b. Activate the “RL” signal on the DTE. If you are not sure which lead is the “RL” signal, ...

  • Patton electronic 2094 - page 18

    33 34 APPENDIX A P A TTON MODEL 2094 SPECIFICA TIONS Network Data Rate: 2.048 Mbps Network Connector: RJ-48C Nominal Impedance: 120 ohm (75 ohm available when using Patton Model 460 Balun) DTE Interface: V .35 (DCE Orientation) on Male M/34 Line Coding: Selectable AMI or HDB3 Line Framing: G.703 (Unframed) or G.704/G.732 (Framed) CAS Multiframing: ...

  • Patton electronic 2094 - page 19

    35 36 APPENDIX C P A TTON MODEL 2094 F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Model # Description 2094/CM/UI .....................V .35 to E1 Converter (V .35 M/34 Male, UI) 10 - 09F ...........................6 Foot Control Port Cable, 25 mm to DB9F 08055DCUI......................Universal Input Power Supply 10-CISCO-V35FT -1 .........C ...

  • Patton electronic 2094 - page 20

    37 38 APPENDIX D (continued) P A TTON MODEL 2094 INTERF ACE PIN ASSIGNMENTS M/34 Connector , T erminal Interface Pin # Signal A GND (Earth Ground/Shield) B SGND (Signal Ground) D CTS (DCE Source) E DSR (DCE Source, Always On) F CD (DCE Source) L LL (Local Loop, DTE Source) M TM (T est Mode Indicator (DCE Source) N RL (Remote Loop, DTE Source) P TD ...

Manufacturer Patton electronic Category Marine Battery

Documents that we receive from a manufacturer of a Patton electronic 2094 can be divided into several groups. They are, among others:
- Patton electronic technical drawings
- 2094 manuals
- Patton electronic product data sheets
- information booklets
- or energy labels Patton electronic 2094
All of them are important, but the most important information from the point of view of use of the device are in the user manual Patton electronic 2094.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Patton electronic 2094, service manual, brief instructions and user manuals Patton electronic 2094. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Patton electronic 2094.

A complete manual for the device Patton electronic 2094, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Patton electronic 2094 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Patton electronic 2094.

A complete Patton electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Patton electronic 2094 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Patton electronic 2094, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Patton electronic 2094, that we can find in the current document
3. Tips how to use the basic functions of the device Patton electronic 2094 - which should help us in our first steps of using Patton electronic 2094
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Patton electronic 2094
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Patton electronic 2094 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Patton electronic 2094?

Use the form below

If you did not solve your problem by using a manual Patton electronic 2094, ask a question using the form below. If a user had a similar problem with Patton electronic 2094 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)