    USER GUIDE SCC-CO20 Isolated Current Output Module The SCC-CO20 is an isolated curren t output module that output s up to 20 mA. The output current lev el is proportional to the voltage applied to the module by an analog output channel of an E/M Series D A Q device. Conventions The following conventions are used in this guide: < > Angle brack ...

  • National Instruments SCC-CO20 - page 2

    SCC-CO20 Isolated Cu rrent Output Module User Guide 2 ni.com italic Italic text denotes variables, emphasis , a cross-reference, or an introduction to a key concept. Italic te xt also deno tes text that is a placeholder for a word or v alue that you must supply . monospace T e x t in this font denotes text or ch aracters that you should enter from ...

  • National Instruments SCC-CO20 - page 3

    © National Instruments Corpor ation 3 SCC-CO20 Isolated Curren t Output Module User Guide ❑ T o ols – 1/8 in. flathead scre wdri ver – Numbers 1 and 2 Phillips screwdriv er s – W ire insu lation stripper Note Software scaling of measurements is not supported on the Macintosh operating system. Refer to the SCC-CO20 Module Pin Assignments se ...

  • National Instruments SCC-CO20 - page 4

    SCC-CO20 Isolated Cu rrent Output Module User Guide 4 ni.com Figure 1. SCC-CO20 Sign al Connections to E/M Series DAQ Device Using the Isolated Loop Supply of the SCC-CO20 You can connect the SCC-CO20 to a load using either the isolated internal loop supply or an external supply. Th e internal loop supply outputs a voltage of 15 V with respect to t ...

  • National Instruments SCC-CO20 - page 5

    © National Instruments Corpor ation 5 SCC-CO20 Isolated Curren t Output Module User Guide Note If your load is g rounded and you are usin g the internal supply , connect the load ground to the current sink terminal at pin 2 on th e SCC-CO20. Do not connect the load ground to the isolated ground terminal because do ing so could defeat the module is ...

  • National Instruments SCC-CO20 - page 6

    SCC-CO20 Isolated Cu rrent Output Module User Guide 6 ni.com Figure 3. Connecting T wo SCC-CO20 Module s to a Higher-R esistance Load SCC-CO20 1 2 + – 15 V iso 3 SCC-CO20 1 2 + – 15 V iso 3 Load SUPPL Y SINK ISO GND SUPPL Y I I ...

  • National Instruments SCC-CO20 - page 7

    © National Instruments Corpor ation 7 SCC-CO20 Isolated Curren t Output Module User Guide Using an External Loop Supply In order for the current sink to oper ate properly with an external loop supply, the voltage must be within the range of 3 to 42 V. If the voltage is too high, overheating can occur and damage the module. Figure 4 shows four conf ...

  • National Instruments SCC-CO20 - page 8

    SCC-CO20 Isolated Cu rrent Output Module User Guide 8 ni.com Figur e 5. Connecting the SCC-CO20 to a Grounded External Loop Supply and a Grounded Load For information about how to conf igu re the SCC-CO20 modul e using NI-D A Qmx, refer to the SCC Quick Start Guide . Calibrating Gain and Offset Errors The SCC-CO20 is calibrated at the f actory befo ...

  • National Instruments SCC-CO20 - page 9

    © National Instruments Corpor ation 9 SCC-CO20 Isolated Curren t Output Module User Guide Note Normally you would adjust to 0 μ A in order to calibrate the of fset, but because the SCC-CO20 cannot source current, it is impossi ble to know when you ha ve adjusted past 0 μ A. Using the SCC-CO20 The SCC-CO20 is a 0 to 20 mA pr ogrammable current si ...

  • National Instruments SCC-CO20 - page 10

    SCC-CO20 Isolated Curr ent Output Module User Guide 10 ni.com Specifications These ratings are typical at 25 ° C unless otherw ise stated. Electrical Number of output channels ................. ....1 Output referencing .............. ................ ....Nonreferenced (floating) Input range .......................... ........... .........0 to 10 V ...

  • National Instruments SCC-CO20 - page 11

    © National Instruments Corporat ion 11 SCC-CO20 Isolated Curren t Output Module User Guide Physical Figure 6. SCC-CO20 Dimensions Weight .................... .............. ........... ....... 28 g (1.0 oz) I/O connectors ...................... .............. .... One 20-pin right-angle male connector One 3-pin screw terminal Field-wiring diameter ...

  • National Instruments SCC-CO20 - page 12

    SCC-CO20 Isolated Curr ent Output Module User Guide 12 ni.com Environmental Operating temperature .. .............. ............0 to 50 °C Storage temperature .............. .............. ....–20 to 70 °C Humidity .............. ............ .............. .........10 to 90% RH, noncondensing Maximum altitude ................. .............. . ...

  • National Instruments SCC-CO20 - page 13

    © National Instruments Corporat ion 13 SCC-CO20 Isolated Curren t Output Module User Guide Online Product Certification Refer to the product Declaration of Conformity (DoC) fo r additional regulatory compliance information. To obtain pro duct certifications an d the DoC for this product, visit ni.com/certification , search by model number or produ ...

  • National Instruments SCC-CO20 - page 14

    SCC-CO20 Isolated Curr ent Output Module User Guide 14 ni.com SCC-CO20 Module Pin Assignments Figure 7 shows the I/O connector pin s on the bottom of the modul e. Figure 7. SCC-CO20 Bottom View T able 1 lists the signal connect ion corresponding to each pin. 1P i n 1 2P i n 2 3 PWB Ke y 4 P i n 1 9 5P i n 2 0 Table 1. SCC-CO20 Pin Signal Connection ...

  • National Instruments SCC-CO20 - page 15

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information a bout National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s. For patents covering Natio ...

Manufacturer National Instruments Category Network Card

Documents that we receive from a manufacturer of a National Instruments SCC-CO20 can be divided into several groups. They are, among others:
- National Instruments technical drawings
- SCC-CO20 manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments SCC-CO20
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments SCC-CO20.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments SCC-CO20, service manual, brief instructions and user manuals National Instruments SCC-CO20. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments SCC-CO20.

A complete manual for the device National Instruments SCC-CO20, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments SCC-CO20 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments SCC-CO20.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments SCC-CO20 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments SCC-CO20, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments SCC-CO20, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments SCC-CO20 - which should help us in our first steps of using National Instruments SCC-CO20
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments SCC-CO20
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments SCC-CO20 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments SCC-CO20?

Use the form below

If you did not solve your problem by using a manual National Instruments SCC-CO20, ask a question using the form below. If a user had a similar problem with National Instruments SCC-CO20 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)