Enviro 50-1574 - page 1
PELLET ST OVE Ev olution PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area. SHERWOOD INDUSTRIE ...
-
Enviro 50-1574 - page 2
2 Safety Warnings & Recommendations..................................................................................... ..........3 Installation................................................................................................................................ .....6 Rating Label Location............................................ ...
-
Enviro 50-1574 - page 3
3 Safety W arnings & R ecommend a tions * This manual is designed for the technician in conjunction with the owner’s manual. * Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Any unauthorized modif ...
-
Enviro 50-1574 - page 4
4 Safety W arnings & R ecommend a tions CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will v ary due to the ash content of the f uel used and the oper ation of the stove. It is advisable to inspect and clean the exhaust vent semi- annually or every two tons of pellets. The appliance, flue ga ...
-
Enviro 50-1574 - page 5
5 Safety W arnings & R ecommend a tions FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “ Air Tight Homes” or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly . NOTE: Extractor fans when operating in the ...
-
Enviro 50-1574 - page 6
Remove the two (2) wood screws (one on either side of the unit) to remove the unit from the pallet. Inst alla tion R ATING L ABEL L OCATION : The rating label is located on the inside of the ash pan co ver . D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, gara ...
-
Enviro 50-1574 - page 7
Inst alla tion D IMENSIONS : 7 IMPOR T ANT : When not installing the optional Hearth Pad on the unit, the minimum requirements for protection on combustibles floors are a width of 620mm (24”) & depth of 670mm (26”) under the unit. 22 1 / 4 " (565 mm) 33 1 / 16 " (840 mm) 21 1 / 4 " (539 mm) 5 13 / 16 " (147 mm) 26 ...
-
Enviro 50-1574 - page 8
Inst alla tion C LEARANCES TO C OMBUSTIBLES : This unit can be installed on a combustible floor when installed with the optional hearth pad part 50-1568 (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability . A LCOVE C LEARANCES : This unit may be installed in an ...
-
Enviro 50-1574 - page 9
9 Inst alla tion H EARTH P AD P EDESTAL I NSTALLATION : This unit can be installed on a combustible floor (e.g. linoleum, hardwood flooring) when the Optional Hearth Pad is installed. If this unit is to be installed onto a carpeted surf ace, a solid pad must be used underneath the Optional Hearth P ad for stability . Carefully place the the pel let ...
-
Enviro 50-1574 - page 10
10 hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust above the inlet elev ation. It is recommended that at least fiv e feet of vertical pipe be installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the possibi ...
-
Enviro 50-1574 - page 11
Inst alla tion O UTSIDE F RESH -A IR C ONNECTION : This Heater must have adequate air for proper combustion in the room that it is installed. Figure 7: Outside Air Connection. E XHAUST A ND F RESH A IR I NTAKE L OCATIONS : The Exhaust Starter Tube can be installed 2 ways: Angled towards the center - Use a T ee with vertical for a “centered” ver ...
-
Enviro 50-1574 - page 12
Figure 10: Corner Installation. Inst alla tion M OBILE H OME I NSTALLATION : 4" (10 cm) 4" (10 cm) Fresh Air Intake W all thimble manufactured by pellet vent manufacturer . ENVIRO EF5 1 / 4 ” Lag Bolts Securely Fastened Ground Wire Directly to Metal Chassis Optional Hearth Pad Flooring Steel Frame ● Secure the heater to the floor usin ...
-
Enviro 50-1574 - page 13
13 Inst alla tion H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION : Vent installation: install vent at clearances specified by the v ...
-
Enviro 50-1574 - page 14
Inst alla tion T HROUGH W ALL W ITH V ERTICAL R ISE AND H ORIZONTAL T ERMINAT ...
-
Enviro 50-1574 - page 15
15 2 ft (61 cm) Rain Cap (ensure cap is at least 3ft (91cm) above the roof at the lowest point) Roof Flashing Roof Rafter Fire Stop with Support Collar Ceiling Joist V ertical V ent Pipe Clean Out T ee with Pipe Adapter EF 5 NOTE: All vent sections must maintain 3 inches (7.6 cm) clearances to combustibles. Inst alla tion I NSIDE V ERTICAL I NSTALL ...
-
Enviro 50-1574 - page 16
H EARTH M OUNT I NSTALLATION : EF 5 Existing Fireplace Clean Out T ee Fireplace Damper Location Rain Cap Seal Plate V ent Pipe (single wall stainless flex pipe or PL vent) Existing Masonary Flue Flexible V ent Connector (Use this 5 ft section of pipe to vent past fireplace damper or smoke shelf) Inst alla tion Rain cap Flashing 24" (61 cm) 4&q ...
-
Enviro 50-1574 - page 17
17 Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER : The Evolution can be equipped with an externally mounted exhaust blower . This optional kit includes all components necessary to install the exhaust blower on any vertical w all surface. 1. Remov e the left hand cabinet side by removing the two (2) screws down the front. Loosen the three screw ...
-
Enviro 50-1574 - page 18
Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : Electrical Cable EF 5 90° Elbow 45°Elbow with Rodent screen or stainless steel termination hood 2ft Riser Pipe Adaptor Exterior Blower and Housing W all Strap T o supply power to the exhaust Install an amour coated electrical cable fr om ...
-
Enviro 50-1574 - page 19
19 EF5 Roof Sheathing Rain Cap Roof Flashing Roof Rafters Ceiling Joists V ent Pipe Exterior W all Sheathing Outside V ent T ermination Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - V ERTICAL T ERMINATION : F ollow the previous pages for through wall instal lations. Ensure that vent pipe is properly secured to ...
-
Enviro 50-1574 - page 20
Inst alla tion T HERMOSTAT I NSTALLATION : 1. Install the wall thermostat (12 or 24 V olt rated) in a location that is not to close too the unit but will effectively heat the desir ed area. 2. Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat. O PTIONAL S LIDER /D AMPER I NSTALLATION : If the unit has been p ...
-
Enviro 50-1574 - page 21
21 Inst alla tion S LIDER /D AMPER S ET -U P : This is used to regulate the airflow through the pellet stove. The slider damper should be set by a trained technician using magnehelic. The slider damper is located behind the left side panel. T o open the left side panel, undo the one screw located in the upper front corner of the cabinet side betwee ...
-
Enviro 50-1574 - page 22
T roubleshooting DO NOT: ● Service the stove with wet hands. The sto ve is an electrical appliance, which ma y pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication. WHAT TO DO IF: 1. The sto ...
-
Enviro 50-1574 - page 23
23 T roubleshooting ü P oor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust T emperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now operates properly , the unit may require cleaning or a new sensor . Contact your local dealer for service. ü ...
-
Enviro 50-1574 - page 24
T roubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the fan button; does the fan come on? Press again to verify that the blower turns on; if , not contact your local dealer for service. 8. Ignitor- the pellets will not light. ü Everything else in the stov e operate ...
-
Enviro 50-1574 - page 25
25 W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey Grey Grey Purple Purple Blue 115V Black 220V Brown Black Black Black Blue Black Armor Cable Supplied Vacuum Switch Combustion Blower Optional Exterior Exhaus ...
-
Enviro 50-1574 - page 26
P ar ts List Reference # Description Part # 1 120°F (49°C) Ceramic F an T emperatur e Sensor EC-001 Window Channel T ape - 1.8m (72”) EC-058 2 Auger Motor - 220V EF-001-220V Combustion Blower Mounting Gasket EF-011 Combustion Blower Housing Gasket (Circular) EF-012 3 High Limit T emp Sensor 200°F (93°C) Manual R eset EF-016 4 V acuum Switch - ...
-
Enviro 50-1574 - page 27
27 P ar ts List Reference # Description Part # Door Gasket - 7ft (213 m) 50-088 23 T op Louver Set - Nickel 50-097 24 Ash Shelf Louver 50-162 Slider Damper Rod & Knob 50-293 T op Glass Retainer 50-294 Control P anel T ouch Latch 50-323 Circuit Board Wire Harness 50-332 Hopper Guard 50-333 25 Convection Blower - 220V 50-513 26 Convection Blower ...
-
Enviro 50-1574 - page 28
P ar ts Diagr am - Components EVOLUTION - Components May 2007 28 ...
-
Enviro 50-1574 - page 29
29 P ar ts Diagr am - Steel EVOLUTION - Steel Components May 2007 ...
-
Enviro 50-1574 - page 30
30 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ NAME OF DEALER: _________________________________________ ADDRESS: _________________________________________ ____ ...
Do you have a question concerning Enviro 50-1574?
Use the form below
If you did not solve your problem by using a manual Enviro 50-1574, ask a question using the form below. If a user had a similar problem with Enviro 50-1574 it is likely that he will want to share the way to solve it.