Manual Campbell Manufacturing CS510

12 pages 0.11 mb
Download

Go to site of 12

Summary
  • Campbell Manufacturing CS510 - page 1

    CS510 OXYGUARD DISSOLVED OXYGEN PROBE INSTRUCTION MANUAL 1/00 COPYRIGHT (c) 2000 CAMPBELL SCIENTIFIC, INC. ...

  • Campbell Manufacturing CS510 - page 2

    This is a blank page. ...

  • Campbell Manufacturing CS510 - page 3

    The CS510-L Oxyguard Dissolved Oxygen Probe is manufactured by Point Four Systems Incorporated. Point Four’s conditions of sale and return policy apply to these items. Products may not be returned without prior authorization. To obtain an RMA number contact Point Four Systems, Inc., phone (604) 936-9936. NOTE: if the product has been exposed to h ...

  • Campbell Manufacturing CS510 - page 4

    This is a blank page. ...

  • Campbell Manufacturing CS510 - page 5

    1 CS510 OxyGuard Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system. The OxyGuard Stationary Probe meets these criteria for the measurement of dissolved oxygen. 1. General Information The OxyGuar d Stationary Probe is a galv anic prob e which pro duces a millivo lt signal proporti onal t o the amo ...

  • Campbell Manufacturing CS510 - page 6

    CS510 OxyGuard Dissolved Oxygen Probe 2 2. Specifications Principle of Measurement: Membrane covered polarographic oxygen probe — self polarizing galvanic cell Output Si gnal: 5 mV per mg/ l, 2 mV per % /vol nomi nal Accuracy: Better than +/- 2 % of reading +/- 1 digit when calibration temperature equals measuring temperature +/- 5 C Repeatabilit ...

  • Campbell Manufacturing CS510 - page 7

    CS510 OxyGuard Dissolved Oxygen Probe 3 3. Service Kit Spare membr ane cap with fitted membran e. 50 ml electrolyte. Spare anode and O-ring. FIGURE 3-1. Exploded View of CS510-L 4. Optional Probe Accessories Agitator for s t agnant condi t ions . Probe Mou nting assem bly for waste water installation s. Flow-through and by-pass fittings. EasyCal ca ...

  • Campbell Manufacturing CS510 - page 8

    CS510 OxyGuard Dissolved Oxygen Probe 4 FIGURE 5-1. Preventing Bio-fouling of the CS510-L The PT4 Agitator overcomes thes e problems . The devi ce is des i gned so t hat a soft brist le brus h sw eeps across t he probe membrane or se ns or ti p. This s weepi ng action of the brush provi des t he required w ate r veloci ty as wel l as prevent s the ...

  • Campbell Manufacturing CS510 - page 9

    CS510 OxyGuard Dissolved Oxygen Probe 5 Optional Rep eat Cycle Timer fo r Agitators : Reciprocating action may be controlled by the opt ional sol id s t ate R epeat C ycle Ti mer. It s ends 12 V DC puls e s to the agitator coil. The ON-time is 0. 25 sec. The OFF-time is ad justable fro m 3 to 12 sec.; requires s uppl y vol tage 10 t o 17 VD C ; hou ...

  • Campbell Manufacturing CS510 - page 10

    CS510 OxyGuard Dissolved Oxygen Probe 6 3) Determine the air temperature and barometric pressure. 4) Usi ng a cali brati on chart s uch as that provided i n the probe ’ s manual, determine the oxygen concentrati on of the air. 5) Use the followin g equatio n to calculate the m ultiplier: M = P/R M = Multiplier P = Concentrati on in P PM of t he a ...

  • Campbell Manufacturing CS510 - page 11

    CS510 OxyGuard Dissolved Oxygen Probe 7 The following instructions in program table 2 would trigger the agitator as discussed in the agitator manual: *Table 2 Program 02: 2.0 Execution Interval (seconds) 1: Do (P86) 1: 41 Set Port 1 High ; Use port number as wired 2: Excitation with Delay (P22) 1: 1 Ex Channel 2: 0 Delay W/Ex (units = 0.01 sec) 3: ...

  • Campbell Manufacturing CS510 - page 12

    CS510 OxyGuard Dissolved Oxygen Probe 8 This is a blank page. ...

Manufacturer Campbell Manufacturing Category Oxygen Equipment

Documents that we receive from a manufacturer of a Campbell Manufacturing CS510 can be divided into several groups. They are, among others:
- Campbell Manufacturing technical drawings
- CS510 manuals
- Campbell Manufacturing product data sheets
- information booklets
- or energy labels Campbell Manufacturing CS510
All of them are important, but the most important information from the point of view of use of the device are in the user manual Campbell Manufacturing CS510.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Campbell Manufacturing CS510, service manual, brief instructions and user manuals Campbell Manufacturing CS510. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Campbell Manufacturing CS510.

A complete manual for the device Campbell Manufacturing CS510, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Campbell Manufacturing CS510 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Campbell Manufacturing CS510.

A complete Campbell Manufacturing manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Campbell Manufacturing CS510 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Campbell Manufacturing CS510, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Campbell Manufacturing CS510, that we can find in the current document
3. Tips how to use the basic functions of the device Campbell Manufacturing CS510 - which should help us in our first steps of using Campbell Manufacturing CS510
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Campbell Manufacturing CS510
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Campbell Manufacturing CS510 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Campbell Manufacturing CS510?

Use the form below

If you did not solve your problem by using a manual Campbell Manufacturing CS510, ask a question using the form below. If a user had a similar problem with Campbell Manufacturing CS510 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)