  • Empire Comfort Systems DV-35-2SG - page 1

    12434-9-0107 Page 1 DIRECT VENT W ALL FURNACE MODELS DV -25-2SG DV -35-2SG EFFECTIVE DA TE JANUAR Y 2007 W A R N I N G : I f n o t i n s t a l l e d , o p e r a t e d a n d maintained in accordance with the manufactur er's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious ...

  • Empire Comfort Systems DV-35-2SG - page 2

    12434-9-0107 Page 2 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ...................................................................................................... 4 Requirments for Massach ...

  • Empire Comfort Systems DV-35-2SG - page 3

    12434-9-0107 Page 3 • Due to high temperatures the appliance should be located out of traffic and away from furnitur e and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • Y oung children should be carefully supervised when they are in t ...

  • Empire Comfort Systems DV-35-2SG - page 4

    12434-9-0107 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area ...

  • Empire Comfort Systems DV-35-2SG - page 5

    12434-9-0107 Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above ? ...

  • Empire Comfort Systems DV-35-2SG - page 6

    12434-9-0107 Page 6 Introduction Al w a ys c o ns u lt y o ur l oc a l B u i ld i ng D e pa r tm e n t r e ga r d in g regulations, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill ...

  • Empire Comfort Systems DV-35-2SG - page 7

    12434-9-0107 Page 7 Locating Gas Supply The gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Note: Never use plastic pipe. Check to confirm whether your loca ...

  • Empire Comfort Systems DV-35-2SG - page 8

    12434-9-0107 Page 8 DV -25-2 SHOWN UNIT IS SUPPORTED BY WALL BRACKET 4 ½”(1 14mm)MIN. WALL DV -25, DV -35 13” (330mm) MAX. WALL DV -25, DV -35 MOUNTING PLA TE (CAULK UNDER FLANGE) VENT CAP FLUE OUTLET TUBE EXTENDS 2 ½”(64mm) BEYOND W ALL AIR INLET TUBE EXTENDS ½”(13mm) BEYOND W ALL OUTSIDE W ALL UNIT F ASTENED TO WALL WITH (2) SCREWS 4? ...

  • Empire Comfort Systems DV-35-2SG - page 9

    12434-9-0107 Page 9 On solid wall, when using wall stu ds for attac hmen t of wall mountin g bracket, fasten wall mounting bracket to wall studs with (2) #10 x 1 1/2" (38mm) screws provided and fasten (2) additional #10 x 1 1/2" (38mm) screws provided through the wall mounting bracket and into the solid wall. On shee t roc k, when usi ng ...

  • Empire Comfort Systems DV-35-2SG - page 10

    12434-9-0107 Page 10 W arning: When vinyl siding vent kit, DV -822 or 2" x 4" (51mm x 102mm) framing is added to an existing installation (furnace is installed) do not attempt to add sections of pipe to the flue outlet tube or air inlet tube. An air tight seal is required for both tubes. Refer to Parts List, page 14 to order tubes. Milli ...

  • Empire Comfort Systems DV-35-2SG - page 11

    12434-9-0107 Page 1 1 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTIN ...

  • Empire Comfort Systems DV-35-2SG - page 12

    12434-9-0107 Page 12 The correct flame will be almost horizontal, blue and will extend past the thermopile 1/4" (6mm). The flame will surround the thermopile just below the tip. On propane (LP-gas) slight yellow might occur where the pilot flame and burner flame meet. Natural gas pilots require adjusting when the inlet pressure is above 5& ...

  • Empire Comfort Systems DV-35-2SG - page 13

    12434-9-0107 Page 13 1. Lit match goes out as it enters lighter port. a. Certain wind conditions will blow out match. Ignite match, and as it flares, thrust match through opening. b. Open nearby door or window and relight pilot. 2. Pilot flames but goes out when knob is released. a. See Lighting Instructions. Relight Pilot. b. Relight the pilot a ...

  • Empire Comfort Systems DV-35-2SG - page 14

    12434-9-0107 Page 14 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Index Part No. Number Description USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. 1 DV -769 V ent Cap 2 DV -131 Outside Mounting Plate 3 DV -548 Air Inlet T ube 4 ...

  • Empire Comfort Systems DV-35-2SG - page 15

    12434-9-0107 Page 15 P AR TS VIEW ...

  • Empire Comfort Systems DV-35-2SG - page 16

    12434-9-0107 Page 16 OPTIONAL BLOWER DRB-1 V ented Room Heaters RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Direct V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6), remove casing front. 1. For DV -25-(1, 2)SG and DV -35-(1, 2)SG, remove casing front ...

  • Empire Comfort Systems DV-35-2SG - page 17

    12434-9-0107 Page 17 Cleaning The blower wheel will collect lint and could require cleaning once a year . If the air output decreases or the noise level increases, it indicates a dirty wheel. Complete removal of the wheel and scrubbing it with a brush under flowing water is recommended. Oiling The blower motor has an oil hole located on each end o ...

  • Empire Comfort Systems DV-35-2SG - page 18

    12434-9-0107 Page 18 SER VICE NOTES ...

  • Empire Comfort Systems DV-35-2SG - page 19

    12434-9-0107 Page 19 SER VICE NOTES ...

  • Empire Comfort Systems DV-35-2SG - page 20

    12434-9-0107 Page 20 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

Manufacturer Empire Comfort Systems Category Furnace

Documents that we receive from a manufacturer of a Empire Comfort Systems DV-35-2SG can be divided into several groups. They are, among others:
- Empire Comfort Systems technical drawings
- DV-35-2SG manuals
- Empire Comfort Systems product data sheets
- information booklets
- or energy labels Empire Comfort Systems DV-35-2SG
All of them are important, but the most important information from the point of view of use of the device are in the user manual Empire Comfort Systems DV-35-2SG.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Empire Comfort Systems DV-35-2SG, service manual, brief instructions and user manuals Empire Comfort Systems DV-35-2SG. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Empire Comfort Systems DV-35-2SG.

A complete manual for the device Empire Comfort Systems DV-35-2SG, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Empire Comfort Systems DV-35-2SG by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Empire Comfort Systems DV-35-2SG.

A complete Empire Comfort Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Empire Comfort Systems DV-35-2SG - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Empire Comfort Systems DV-35-2SG, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Empire Comfort Systems DV-35-2SG, that we can find in the current document
3. Tips how to use the basic functions of the device Empire Comfort Systems DV-35-2SG - which should help us in our first steps of using Empire Comfort Systems DV-35-2SG
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Empire Comfort Systems DV-35-2SG
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Empire Comfort Systems DV-35-2SG in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Empire Comfort Systems DV-35-2SG?

Use the form below

If you did not solve your problem by using a manual Empire Comfort Systems DV-35-2SG, ask a question using the form below. If a user had a similar problem with Empire Comfort Systems DV-35-2SG it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)