Manual Datalogic Scanning QS2500

76 pages 0.76 mb
Download

Go to site of 76

Summary
  • Datalogic Scanning QS2500 - page 1

    QuickScan ® QS2500 Handheld Bar Code Scanner Product Reference Guide ...

  • Datalogic Scanning QS2500 - page 2

    Datalogic Scanning, Inc. 959 T erry Street Eugene, Oregon 97402 T elephone: (541) 683-5700 F ax: (541) 345-7140 An Unpublished W ork - All r ights reser ved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in an y form or by an y means without pr ior written per mission of Datalogic ...

  • Datalogic Scanning QS2500 - page 3

    Product Reference Guide 1 Table of Contents Installation ................................. ........................................................ 1 Keyboard Wedge ......................................................................................... 1 Wand Emulation .............................................................................. ...

  • Datalogic Scanning QS2500 - page 4

    2 QS2500 Standard 2 of 5 ......................................................................................... 54 Code 16K .................................................................................................56 PDF417 ....................................................................................................57 Italian Pharm ...

  • Datalogic Scanning QS2500 - page 5

    Product Reference Guide 1 Installation Complete the following steps for the appropriate interface. Keyboard Wedge 1. T urn off the terminal or computer . 2. Disconnect the keyboar d cable from the back of the terminal or computer . 3. Connect the QS2500 to the terminal or computer using the appro- priate interface cable. 4. T urn the terminal or co ...

  • Datalogic Scanning QS2500 - page 6

    2 QS2500 USB 1. Plug the USB cable into the terminal or computer . IBM 1. T urn off the terminal or computer . 2. Connect the appropriate interface cable to the terminal or com- puter . 3. T urn the terminal or computer on. NO TE If the QS2500 does not operate, turn off the terminal or computer immediately and chec k all connections. If necessary , ...

  • Datalogic Scanning QS2500 - page 7

    Product Reference Guide 3 Programming the QS2500 T o program the QS2500, you must scan a series of programming bar codes in the correct or der . The inside back cover of this manual contains a table of alphanumeric bar codes need ed to program the various options. T o program each option: 1. Scan the S tart Program bar code abo ve the list of optio ...

  • Datalogic Scanning QS2500 - page 8

    4 QS2500 Resetting the QS2500 T o return all QS2500 option settings to the factor y defaults, scan the fol- lowing two bar codes, in the or der shown: Interfaces The QS2500 supports Keyboard W edge, RS-232, W and Emulation, IBM and USB interfaces. The correct interfac e cable is included for the scanner interface type you ordered. Keyboard Wedge As ...

  • Datalogic Scanning QS2500 - page 9

    Product Reference Guide 5 Function Key: When this option is enabled, the QS2500 outputs bar code ASCII values from 01 hex to 1F hex as function-key presses in your applica- tion. See the table of ASCII codes I n Appendix C on page 66 . Option Bar Code Option Alphanumeric Entry Keyb oa rd T yp e IBM A T , PS/2 00* Reserved 01 - 06 Ke yboard La yout ...

  • Datalogic Scanning QS2500 - page 10

    6 QS2500 Numeric Key: I f your application accepts only keypad numeric code, use setting 01 to make the QS2500 output code as numeric-keypad presses when it reads digits. If you use setting 02 , the scanner will send the three digit ACSCII number for all data us ing the Alt and numeric keypad key- codes. Setting 02 prev ents the caps Lock from affe ...

  • Datalogic Scanning QS2500 - page 11

    Product Reference Guide 7 Option Bar Code Option Alphanumeric Entry Function Ke y Disable 00* Enable 01 Numeric Ke y Alphabetic key 00* Numeric keypad only 01 Alt+Keypad 02 Caps Lock Caps lock 00 No caps lock 01* Pow e r - O n S i m u l a t i o n Disable 00* Enable 01 Interc haracter Delay 0–99 (msec.) 00–99 02* Block T ransmission Delay 0–99 ...

  • Datalogic Scanning QS2500 - page 12

    8 QS2500 Wand Emulation NO TES Support for wand emulation is av ailable only with the ke yboard wedge interface. Use the bar codes below to enable and config- ure wand emulation. Option Bar Code Option Alphanumeric Entry Interface selection Keyboar d Wedge 00* W and Emulation 02 Bar/Space P olarity Bar high/Space low 00* Bar low/Space high 01 Idle ...

  • Datalogic Scanning QS2500 - page 13

    Product Reference Guide 9 Margin Dela y (pixels) 15 (Default) 00–99 (x 10 pixels) 15* 00–99 T ransmit Delay (Milliseconds) 30 (default) 00–99 (x 10 msec.) 30* 00–99 Option Bar Code Option Alphanumeric Entry $$ Exit ...

  • Datalogic Scanning QS2500 - page 14

    10 QS2500 RS-232 CTS = Clear T o Send (Har dware Signal) R TS = Request T o Send (Hardwar e Signal) Xon = T ransmit On (ASCII Code 11 hex ) Xoff = T ransmit Off (ASCII Code13 hex ) ACK = Ack nowl ed ge ( ACS II Cod e 0 6 hex ) NAK = N ot Acknowledge (ASCII Code 15 hex ) Option Bar Code Option Alphanumeric Entry Baud Rate 300 Baud 00 600 Baud 01 120 ...

  • Datalogic Scanning QS2500 - page 15

    Product Reference Guide 11 RS-232 Advanced Features Flow Control None: The communication uses only TxD and RxD signals, without regard for any hardware or software handshaking pr otocol. RTS/CTS: I f the QS2500 wants to send the bar code data to the host com- puter , it will issue the R TS signal first, wait for the CTS signal from the host compute ...

  • Datalogic Scanning QS2500 - page 16

    12 QS2500 RS-232 Advanced Features — continued Response Delay This delay is used for serial communication. I t is the amount of time the QS2500 waits for handshaking acknowledgment from the host computer . Option Bar Code Option Alphanumeric Entry Flow Contr ol None 00* RTS /C TS 01 Xon/Xoff 02 A CK/NAK 03 Datalogic Aux. Po r t a a. Reading PDF41 ...

  • Datalogic Scanning QS2500 - page 17

    Product Reference Guide 13 IBM Interface (46XX/USB) The next few pages contain the programming labels for configuring the IBM interface to match your interface configuration and symbology spe- cific requir ements. These bar codes to select the IBM USB interface. Start Program Option Bar Code Option Alphanumeric Entry IBM 46xx port 17 00 IBM 46xx po ...

  • Datalogic Scanning QS2500 - page 18

    14 QS2500 IBM Options IBM 46xx Code 39 Conversion This feature enables/disables the scanner ’ s ability to set the symbology identifier for the specified symbology to C ode 39 bef ore s en din g th e la bel data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM P ort 5B; Code 93 and Codabar for IBM P ort 9B. IBM-USB Device Ty ...

  • Datalogic Scanning QS2500 - page 19

    Product Reference Guide 15 IBM Host Commands S pecifies whether the scanner will pr ocess or ignore IBM host commands. Option Bar Code Option Alphanumeric Entry IBM 46xx Code 39 Con version Disable 00* Enable 01 IBM USB Device T ype T able-top 00 Handheld 01* Max. Host T ransmit Message Length 0x00–0xF6 00* Start Program Exit Start Program Option ...

  • Datalogic Scanning QS2500 - page 20

    16 QS2500 Scanning Scanning Mode Good-read off: The trigger button must be pressed to activate scanning. The light source of the QS2500 stops sc anning when there is a successful read or no code is decoded after the standby duration has elapsed. Momentary: The trigger button acts as a sw itch. Pr essing the button acti- vates scanning and releasing ...

  • Datalogic Scanning QS2500 - page 21

    Product Reference Guide 17 Double Confirm If this option is enabled, the QS 2500 will require a several successful decodings to confirm the bar code data. Larger settings will make misreads less likely . If a double confirm is set, the multifield scan function will be disabled. Option Bar Code Option Alphanumeric Entry Scanning Mode Good-read off 0 ...

  • Datalogic Scanning QS2500 - page 22

    18 QS2500 Global Minimum/Maxim um Code Length: Global minimum and maximum length can be set to qualify data entry . The length is defined as the actual bar code data length to be sent. Labels with length exceeding these limits will be rejected. Make sur e that the minimum-length setting is no greater than the maximum-length setting; otherwise, the ...

  • Datalogic Scanning QS2500 - page 23

    Product Reference Guide 19 In ver ted Image Scan: With this option enabled, the QS2500 will scan black/white bar codes with a white/black background. CTS T rigger: This operation enables an external device to control scanning by applying an external trigger signal to the CTS input. When activ e, this signal causes scanning to begin as the QS2500’ ...

  • Datalogic Scanning QS2500 - page 24

    20 QS2500 Beep/Tone/LED Settings P ower-On Alert: After power-on, the QS2500 will generate an alert signal to indicate a successful self-test. LED Control: After each successful bar code re ading, the LED above the QS2500 will light up. Beep Control: After each successful bar code r eading, the QS2500 will beep. Beep Loudness/Beep-T one Frequency/B ...

  • Datalogic Scanning QS2500 - page 25

    Product Reference Guide 21 Option Bar Code Option Alphanumeric Entry Pow e r - O n A l e r t Disable 00 Enable 01* LED Indication Disable 00 Enable 01* Beeper Indication Disable 00 Enable 01* Beep Loudness 0–07 00–07 03* Beep-T one Frequency 0–99 (100Hz) 00–99 26* Beep-T one Duration 0–99 (10 msec.) 00–99 10* Beep/Lamp Option 1: Beep &a ...

  • Datalogic Scanning QS2500 - page 26

    22 QS2500 Label Editing (includes Prefix/Suffix) Prefix Characters: U p to 22 ASCII characters may be sent before data. Suffix Characters: U p to 22 ASCII characters may be sent after data. Preamble/P ostamble Characters: These characters ar e affixed to the data automatically when each bar code is decoded. Example: Add a prefix/suffix or pr eamble ...

  • Datalogic Scanning QS2500 - page 27

    Product Reference Guide 23 4. Scan the S tore Settings bar code on the inside back cover . 5. Repeat the same procedur e for the G2 characters. 6. Scan the Exit bar code. 7. Insert the data group 1–4 position. (page 24 .) Option Bar Code Option Alphanumeric Entry Prefix None 00* 1–22 characters 00–ff hex ASCII code Suffix None 00 1–22 chara ...

  • Datalogic Scanning QS2500 - page 28

    24 QS2500 Preamble T ransmission: The preamble will be appended befor e the code data. P ostamble T ransmission: The postamble will be appended after the code data. Insert Data Group 1–4 P osition: The QS2500 offers four positions to insert characters into the bar code data. The position default value of “00” indi- cate no character insertion ...

  • Datalogic Scanning QS2500 - page 29

    Product Reference Guide 25 Code ID T ransmission: Enable this option to transmit the code ID. See page 27 . Code Length T ransmission: A number of data digits can be transmitted before the code data. The total length of the bar code is the number of characters of bar code data without truncated leading or ending digits. Option Bar Code Option Alpha ...

  • Datalogic Scanning QS2500 - page 30

    26 QS2500 Code Name T ransmission: This function is used to show unkno wn bar code symbologies that include all readable symbologies of the QS2500. The code name will be transmitted before the bar code data to identify the symbology . Case Con version: Y ou can set the alpha characters to be displayed as either uppercase or lowercase. Order of tran ...

  • Datalogic Scanning QS2500 - page 31

    Product Reference Guide 27 Symbology Settings UPC-A Read: Fo r m a t : Checksum T ransmission: With this option enabled, the QS2500 will trans- mit the checksum. T runcate Leading/Ending: The leading or ending digits of bar code data characters can be truncated. The QS2500 will beep instead of reading anything when the truncate value is more than t ...

  • Datalogic Scanning QS2500 - page 32

    28 QS2500 Option Bar Code Option Alphanumeric Entry Read Disable 00 Enable 01* Checksum V erification Disable 00 Enable 01* Checksum T ransmission Disable 00 Enable 01* T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff hex ASCII code 00–ff hex <A>* Insertion Group Selection 0–44 00–44 00* S ...

  • Datalogic Scanning QS2500 - page 33

    Product Reference Guide 29 UPC-E Read: Fo r m a t : Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. T runcate Leading/Ending: Same as UPC -A . Se e pa ge 27 . Code Id Setting: Same as UPC-A. S ee page 27 . Insertion Group Selection: Same as UPC-A. S ee page 27 . Supplement Digits: Fo r m a t : T runcate/E ...

  • Datalogic Scanning QS2500 - page 34

    30 QS2500 Option Bar Code Option Alphanumeric Entry Read Disable 00 Enable 01* Checksum V erification Disable 00 Enable 01* Checksum T ransmission Disable 00 Enable 01* T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ffH ASCII code 00–ff hex <E>* Insertion Group Selection 0–44 00–44 00* Supp ...

  • Datalogic Scanning QS2500 - page 35

    Product Reference Guide 31 EAN-13 Read: Fo r m a t : Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. T runcate Leading/Ending: Same as UPC -A . Se e pa ge 27 . Code ID Setting: Same as UPC-A. S ee page 27 . Insertion Group Selection: Same as UPC-A. S ee page 27 . Supplement Digits: Fo r m a t : ISBN/ISSN: ...

  • Datalogic Scanning QS2500 - page 36

    32 QS2500 Checksum T ransmission Disable 00 Enable 01* T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ffH ASCII code 00–ff hex <F>* Insertion Group Selection 0–44 00–44 00* Supplement Digits None 00* 2 digits 01 5 digits 02 UCC/EAN 128 03 Auto Detection 04 ISBN/ISSN Con version Disable 00* ...

  • Datalogic Scanning QS2500 - page 37

    Product Reference Guide 33 EAN-8 Read: Fo r m a t : Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. T runcate Leading/Ending: Same as UPC -A . Se e pa ge 27 . Code ID Setting: Same as UPC-A. S ee page 27 . Insertion Group Selection: Same as UPC-A. S ee page 27 . Supplement Digits: Fo r m a t : T T runcate ...

  • Datalogic Scanning QS2500 - page 38

    34 QS2500 Checksum V erification Disable 00 Enable 01* Checksum T ransmission Disable 00 Enable 01* T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting T wo characters 00–ff hex ASCII code 00–ff hex <FF>* Insertion Group Selection 0–44 00–44 00* Supplement Digits None 00* 2 digits 01 5 digits 02 UC ...

  • Datalogic Scanning QS2500 - page 39

    Product Reference Guide 35 Code 39 Read: Fo r m a t : Checksum V erification: The checksum is optional and presented as the sum mod 43 of the numerical value of the data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Each symbology has own maximum and minimum code le ...

  • Datalogic Scanning QS2500 - page 40

    36 QS2500 Append: This function allows several symbols to be concatenated and be treated as a single entry . The QS2500 will not transmit the embedded appending code (for Code-39, a space). If the append function is enabled and other symbols are read again with the appended code, then the codes are transmitted without the code ID, preamble, or pr e ...

  • Datalogic Scanning QS2500 - page 41

    Product Reference Guide 37 Interleaved 2 of 5 Read: Fo r m a t : Checksum V erification: The checksum is presented as the sum mod 10 of the numerical values of all data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Same as Code 39. See page 35 . (E ven val- ues only ...

  • Datalogic Scanning QS2500 - page 42

    38 QS2500 Option Bar Code Option Alphanumeric Entry Read Disable 00 Enable 01* Checksum V erification Disable 00 Enable 01* Checksum T ransmission Disable 00* Enable 01 Max.Code Length (even va lues only) Use Global Max. 00* 2–64 02–64 Min. Code Length (even va lues only) Use Global Min. 00* 2–64 02–64 T runcate Leading 0–15 00–15 00* T ...

  • Datalogic Scanning QS2500 - page 43

    Product Reference Guide 39 Industrial 2 of 5 Read: Fo r m a t : Maximum/Minim um Code Length: Same as Code 39. See page 35 . T runcate Leading/Ending: Same as UP C-A . Se e pa ge 27 . Code ID Setting: Same as UPC-A. S ee page 27 . Insertion Group Selection: Same as UPC-A. S ee page 27 . Data Digits (V ariable) Chec ksum (Optional) Option Bar Code O ...

  • Datalogic Scanning QS2500 - page 44

    40 QS2500 Matrix 2 of 5 Read: Fo r m a t : Checksum V erification: The checksum is presented as the sum mod 10 of the numerical values of all data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Same as Code 39. See page 35 . T runcate Leading/Ending: Same as UP C-A . ...

  • Datalogic Scanning QS2500 - page 45

    Product Reference Guide 41 Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 Checksum V erification Disable 00* Enable 01 Checksum T ransmission Disable 00* Enable 01 Max. Code Length Use Global Max. 00* 1–64 01–64 Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 ...

  • Datalogic Scanning QS2500 - page 46

    42 QS2500 Codabar Read: Fo r m a t : Checksum V erification: The checksum is presented as the sum mod 16 of the numerical values of all data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Same as Code 39. See page 35 . T runcate Leading/Ending: Same as UP C-A . Se e ...

  • Datalogic Scanning QS2500 - page 47

    Product Reference Guide 43 Max. Code Length Use Global Max. 00* 1–64 01–64 Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff hex ASCII code 00–ff hex <%>* Insertion Group Selection 0–44 00–44 00* Start/End T ype ABCD/ABCD 00* abcd/abcd ...

  • Datalogic Scanning QS2500 - page 48

    44 QS2500 Code 128 Read: Fo r m a t : Checksum V erification: The checksum is presented as the sum mod 103 of all data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Same as Code 39. See page 35 . T runcate Leading/Ending: Same as UP C-A . Se e pa ge 27 . Code ID Set ...

  • Datalogic Scanning QS2500 - page 49

    Product Reference Guide 45 • Append label data with Concatenation Code <GS> (1D hex):<]C1> <Label data 1> <GS> <Label data 2><Checksum> Option Bar Code Option Alphanumeric Entry Read Disable 00 Enable 01* Checksum V erification Disable 00 Enable 01* Checksum T ransmission Disable 00* Enable 01 Max. Code Length ...

  • Datalogic Scanning QS2500 - page 50

    46 QS2500 Code 93 Read: Fo r m a t : Checksum V erification: The checksum is presented as the sum mod 47 of the numerical values of all data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Same as Code 39. See page 35 . T runcate Leading/Ending: Same as UP C-A . Se e ...

  • Datalogic Scanning QS2500 - page 51

    Product Reference Guide 47 Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 Checksum V erification Disable 00 Enable (two digits) 01* Checksum T ransmission Disable 00* Enable 01 Max. Code Length Use Global Max. 00* 1–64 01–64 Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00–15 00* T runcate ...

  • Datalogic Scanning QS2500 - page 52

    48 QS2500 Code 11 Read: Fo r m a t : Checksum V erification: The checksum is presented as the sum mod 11 of all data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit one-digit or two-digit chec ksums, depending upon the setting for checksum verification. Maximum/Minim um Code Length: Same as Code 39. See page 35 ...

  • Datalogic Scanning QS2500 - page 53

    Product Reference Guide 49 MSI/Plessey Read: Fo r m a t : Checksum V erification: The MSI/Plessey code has one or two optional checksum digits. The checksums are calculated as the sum mod 10 or 11 of the data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit one-digit or two-digit checksums, depending upon the se ...

  • Datalogic Scanning QS2500 - page 54

    50 QS2500 Insertion Group Selection: Same as U PC -A . See pa ge 27 . Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 Checksum V erification Disable 00* Mod 10 01 Mod 10/10 02 Mod 11/10 03 Checksum T ransmission Disable 00* Enable 01 Max. Code Length Use Global Max. 00* 1–64 01–64 Mini. Code Length Use Global Min. 00* 1–6 ...

  • Datalogic Scanning QS2500 - page 55

    Product Reference Guide 51 UK/Plessey Read: Fo r m a t : Checksum V erification: The UK/Plessey code has one or two optional checksum digits. The checksums are calculated as the sum mod 10 or 11 of the data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Same as Code ...

  • Datalogic Scanning QS2500 - page 56

    52 QS2500 Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 Checksum V erification Disable 00 Enable 01* Checksum T ransmission Disable 00* Enable 01 Max. Code Length Use Global Max. 00* 1–64 01–64 Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ...

  • Datalogic Scanning QS2500 - page 57

    Product Reference Guide 53 Telepen Read: Fo r m a t : Checksum V erification: The checksum is presented as the sum mod 10 or 11 of the data digits. Checksum T ransmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minim um Code Length: Same as Code 39. See page 35 . T runcate Leading/Ending: Same as UP C-A . Se e p ...

  • Datalogic Scanning QS2500 - page 58

    54 QS2500 Standard 2 of 5 Read: Fo r m a t Maximum/Minim um Code Length: Same as Code 39. See page 35 . T runcate Leading/Ending: Same as UP C-A . Se e pa ge 27 . Code ID Setting: Same as UPC-A. S ee page 27 . Insertion Group Selection: Same as U PC -A . See pa ge 27 . Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00? ...

  • Datalogic Scanning QS2500 - page 59

    Product Reference Guide 55 Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 Max. Code Length Use Global Max. 00* 1–64 01–64 Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff hex ASCII code 00–ff hex <i> Insertion Group ...

  • Datalogic Scanning QS2500 - page 60

    56 QS2500 Code 16K T runcate Leading/Ending: Same as UP C-A . Se e pa ge 27 . Code ID Setting: Same as UPC-A. S ee page 27 . Insertion Group Selection: Same as U PC -A . See pa ge 27 . Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff ...

  • Datalogic Scanning QS2500 - page 61

    Product Reference Guide 57 PDF417 T runcate leading/ending: Same as UPC-A. See page 27 . Code ID Setting: Same as UPC-A. S ee page 27 . Insertion Group Selection: Same as UPC-A. S ee page 27 . Option Bar Code Option Alphanumeric Entry Read Disable 00 Enable 01* T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting ...

  • Datalogic Scanning QS2500 - page 62

    58 QS2500 Italian PharmaCode Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff hex ASCII code 00–ff hex <p> Insertion Group Selection 0–44 00–44 00* Leading “A” Disable 00* Enable 01 $ Start Program Exit ...

  • Datalogic Scanning QS2500 - page 63

    Product Reference Guide 59 RSS Expanded Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 Max. Code Length Use Global Max. 00* 1–64 01–64 Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff hex ASCII code 00–ff hex <RX> In ...

  • Datalogic Scanning QS2500 - page 64

    60 QS2500 RSS Limited Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01S Max. Code Length Use Global Max. 00* 1–64 01–64 Min. Code Length Use Global Min. 00* 1–64 01–64 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff hex ASCII code 00–ff hex <RL> Insertion Group Sel ...

  • Datalogic Scanning QS2500 - page 65

    Product Reference Guide 61 RSS-14 Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 T runcate Leading 0–15 00–15 00* T runcate Ending 0–15 00–15 00* Code ID Setting 00–ff hex ASCII code 00–ff hex <R4> Insertion Group Selection 0–44 00–44 00* UCC/EAN 128 Emulation Disable 00* Enable 01 $ Start Program Exit ...

  • Datalogic Scanning QS2500 - page 66

    62 QS2500 Appendix - Default Settings Code T ype Read Enable Checksum V erification Enable Checksum T ransmission Enable Code ID UPC-A   A UPC-E   E EAN-13   F EAN-8   FF Code 39  * Interleaved 2 of 5  i Industrial 2 of 5 i Matrix 2 of 5 B Codabar % Code 128  # Code 93  & Code 11 One digi ...

  • Datalogic Scanning QS2500 - page 67

    Product Reference Guide 63 Appendix B - Bar Code Samples UPC-A UPC-E EAN-13 EAN-8 Code 39 XZV Interleaved 2 of 5 Industrial 2 of 5 1 23456 78901 2 0 123456 5 1 234567 890128 1234 5670 * 1234567 * 01234567 0124345 ...

  • Datalogic Scanning QS2500 - page 68

    64 QS2500 Matrix 2 of 5 Codabar Code 128 Code 93 Code 11 MSI/Plessey UK/Plessey Standard 2 of 5 Code 16K 456353663 A1 1 2 +B A 12345 Bcd B 67890 Bcd 654215 67890123 67890123 12345678901 ...

  • Datalogic Scanning QS2500 - page 69

    Product Reference Guide 65 PDF417 Italian PharmaCode RSS Expanded RSS Limited RSS-14 54 9 875623 0H8X L 9 0100123456789050 0112345678901231 0100123456789050 ...

  • Datalogic Scanning QS2500 - page 70

    66 QS2500 Appendix C - ASCII Codes Example: ASCII “CR” = “0D” 01 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right F4 EO T DC4 5 PgUp F5 ENQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Ta b F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Inser t Ctrl+ SO RS F Delete Alt+ SI US ...

  • Datalogic Scanning QS2500 - page 71

    Product Reference Guide 67 Example: ASCII “ A” = “41” 234567 0 SP 0 @ P ` p 1 !1 A Q a q 2 “2 B R br 3 #3 C S c s 4 $4 D Td t 5 %5 E U e u 6 &6FV f v 7 ‘7 G W g w 8 (8 H X h x 9 )9IYi y A :J Zjz B +; K [ k C <L l D -= M ] m E .> N ^ n F /? O _ o D E L L H ...

  • Datalogic Scanning QS2500 - page 72

    68 QS2500 Appendix D - Parameter Setting List Star t Pr ogram Standard P arameter Setting List If you wish to displa y the current configuration of your QS2500 o ver the host terminal/computer, scan the Bar Code standard par ameter setting list bar code. System P arameter Setting List If you wish to displa y the product information and revision n u ...

  • Datalogic Scanning QS2500 - page 73

    Product Reference Guide 69 Appendix E - Alphanumeric Characters 0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Store Settings 9 Exit ...

  • Datalogic Scanning QS2500 - page 74

    70 QS2500 NOTES ...

  • Datalogic Scanning QS2500 - page 75

    ...

  • Datalogic Scanning QS2500 - page 76

    Aus t r al i a Datalogic Scanning Pty Ltd Nor th Ryde, A ustralia T elephone: [61] (2) 9870 3200 F ax: [61] (2) 9878 8688 France and Benelux Datalogic Scanning Sarl LES ULIS Cedex, F rance T elephone: [33] .01.64.86.71.00 F ax: [33].01.64 46.72.44 Germany Datalogic Scanning GmbH Darmstadt, Ger many T elephone: 49 (0) 61 51/93 58-0 F ax: 49 (0) 61 5 ...

Manufacturer Datalogic Scanning Category Barcode Reader

Documents that we receive from a manufacturer of a Datalogic Scanning QS2500 can be divided into several groups. They are, among others:
- Datalogic Scanning technical drawings
- QS2500 manuals
- Datalogic Scanning product data sheets
- information booklets
- or energy labels Datalogic Scanning QS2500
All of them are important, but the most important information from the point of view of use of the device are in the user manual Datalogic Scanning QS2500.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Datalogic Scanning QS2500, service manual, brief instructions and user manuals Datalogic Scanning QS2500. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Datalogic Scanning QS2500.

A complete manual for the device Datalogic Scanning QS2500, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Datalogic Scanning QS2500 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Datalogic Scanning QS2500.

A complete Datalogic Scanning manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Datalogic Scanning QS2500 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Datalogic Scanning QS2500, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Datalogic Scanning QS2500, that we can find in the current document
3. Tips how to use the basic functions of the device Datalogic Scanning QS2500 - which should help us in our first steps of using Datalogic Scanning QS2500
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Datalogic Scanning QS2500
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Datalogic Scanning QS2500 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Datalogic Scanning QS2500?

Use the form below

If you did not solve your problem by using a manual Datalogic Scanning QS2500, ask a question using the form below. If a user had a similar problem with Datalogic Scanning QS2500 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)