    CAST IRON STOVE AND DIRECT -VENT (FREEST ANDING FIREPLACE HEA TER) BURNER SYSTEM ® OWNER’S OPERA TION AND INST ALLA TION MANUAL NA TURAL GAS BURNER SYSTEM MODEL SDVBN(A) PROP ANE/LP GAS BURNER SYSTEM MODEL SDVBP(A) REMOTE READY Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any applianc ...

  • Vanguard Heating SDVBP(A) - page 2

    2 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP burner system, do not place propane/LP supply tank(s) inside any st ...

  • Vanguard Heating SDVBP(A) - page 3

    3 105499 OWNER’S MANUAL P I L O T L O H I OFF ON ON OFF AUTO PRODUCT IDENTIFICA TION Install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA- B149[.1 or .2] Installation Codes (Canada) . *Availa ...

  • Vanguard Heating SDVBP(A) - page 4

    4 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Vanguard cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ...

  • Vanguard Heating SDVBP(A) - page 5

    5 105499 OWNER’S MANUAL Pallet Wood Bolted to Bottom of Stove Body STOVE BODY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body . The bottom pieces of pallet wood will remain bolted to the stove body . 3. Re ...

  • Vanguard Heating SDVBP(A) - page 6

    6 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) CAST IRON STOVE AND DIRECT -VENT BURNER SYSTEM ASSEMBL Y Continued Figure 12 - Attaching Stove Door Step Bolt Door Hinge Threaded Hole Stove Door Stove Bottom Bolt Shoulder Adjusting Nut Bolt Stop Catch Bolt Door Claw Door Figure 13 - Catch Bolt and Door Claw Orientation 10. Attach ...

  • Vanguard Heating SDVBP(A) - page 7

    7 105499 OWNER’S MANUAL WARNING: Never touch the blower wheel while in operation. 7. Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover on right side oppo- site control. WARNING: Failure to position the parts in accordance with sup- plied diagrams or failure to use only parts specifically approved w ...

  • Vanguard Heating SDVBP(A) - page 8

    8 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) LOCATION OF VENT TERMINATION When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 18, page 9. *Check with local codes or with the current CAN/CGA B149[.1 or .2] Installation Codes for Canada or the USA Installations follow the current ...

  • Vanguard Heating SDVBP(A) - page 9

    9 105499 OWNER’S MANUAL Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum] B = clearance to window or d ...

  • Vanguard Heating SDVBP(A) - page 10

    10 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property d ...

  • Vanguard Heating SDVBP(A) - page 11

    11 105499 OWNER’S MANUAL INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed. Snorkel terminations are available for terminations requ ...

  • Vanguard Heating SDVBP(A) - page 12

    12 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 22 - Vent Opening Requirements 3. Attach vent pipe assembly to the burner system. Set stove in fr ...

  • Vanguard Heating SDVBP(A) - page 13

    13 105499 OWNER’S MANUAL VENTING INST ALLA TION Continued Figure 26 - Horizontal Termination Configuration for Rigid Venting Figure 27 - Horizontal Termination Configuration for Rigid Venting Using One 90 ° Elbow Horizontal V enting V ertical (V) Horizontal (H) 37" min. 29" max. (30 ° and 90 ° only , no vertical pipe) 48" min. 4 ...

  • Vanguard Heating SDVBP(A) - page 14

    14 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) Flat Ceiling Installation 1. Cut a 10" square hole in the ceiling us- ing the locating hole as a center point. The opening should be framed to 10"x10" (254mm x 254mm) inside di- mensions, as shown in Figure 22 on page 12 using framing lumber the same size as the cei ...

  • Vanguard Heating SDVBP(A) - page 15

    15 105499 OWNER’S MANUAL VENTING INST ALLA TION Continued Figure 31 - Installing Firestop If area above is not a room, install firestop below framed hole. If area above is a room, install firestop above framed hole. Continued 3. Cut a hole in the roof using the locating hole as a center point. (Cover any ex- posed open vent pipes before cutting h ...

  • Vanguard Heating SDVBP(A) - page 16

    16 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) V enting with T wo 9 0 ° Elbo ws V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Note: V ertical (V 1 ) + V ertical (V 2 ) = 20' max. Figure 36 - Vertical Rigid Venting Configuration U ...

  • Vanguard Heating SDVBP(A) - page 17

    17 105499 OWNER’S MANUAL Figure 37 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V er tical V enting V = 40' max. RVKBK Kit Shown Note: Install restrictor into 4" collar of burner system as shown. HIGH ALTITUDE INSTALLATION Your Vanguard cast iron stove and direct- vent burner system has ...

  • Vanguard Heating SDVBP(A) - page 18

    18 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) Figure 39 - Gas Connection * The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your dealer. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your loc ...

  • Vanguard Heating SDVBP(A) - page 19

    19 105499 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect burner system and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage burner system gas regulator . 2. Cap of f open end of gas pipe where manual shuto ...

  • Vanguard Heating SDVBP(A) - page 20

    20 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) STOVE AND DIRECT -VENT BURNER SYSTEM INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close manual shutoff valve (see Fig- ure 41). 2. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas burner sys- ...

  • Vanguard Heating SDVBP(A) - page 21

    21 105499 OWNER’S MANUAL STOVE AND DIRECT -VENT BURNER SYSTEM INST ALLA TION Continued INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures. WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard wi ...

  • Vanguard Heating SDVBP(A) - page 22

    22 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this burner system with a broken glass door panel or without the glass door panel securely in place. For replacement part in- formation see Replacement Parts , page 31. 1. Remove 2 bolts from bottom of stove and one from the to ...

  • Vanguard Heating SDVBP(A) - page 23

    23 105499 OWNER’S MANUAL Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with freestanding burner system. Do not use if any log(s) are broken (see Replacement Parts , page 31). 1. Remove glas ...

  • Vanguard Heating SDVBP(A) - page 24

    24 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TO TURN OFF GAS TO APPLIANCE 1. Open lower louver panel. 2a. T urn ON/OFF switch to “OFF”. 2b . If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to pre vent draining battery . 3. T urn off all electrical power to the appliance if service is to be p ...

  • Vanguard Heating SDVBP(A) - page 25

    25 105499 OWNER’S MANUAL 1. After lighting, let pilot flame bur n f or about one minute. T urn ga s control knob on the control v alve to ON posi- tion. T urn va ri ab le control knob any- where between HI and LO. Slide the selector switch to the REMO TE posi- tion. Note: The bur ners may light if hand-held remote ON b utton was on when selector ...

  • Vanguard Heating SDVBP(A) - page 26

    26 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if neces ...

  • Vanguard Heating SDVBP(A) - page 27

    27 105499 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off burner system and let cool before cleaning. CAUTION: You must keep control areas, burners, and cir- culating air passageways of burner system and stove clean. Inspect these areas of burner system and stove before each use. Have burner system and stove inspected yearly by a quali- ...

  • Vanguard Heating SDVBP(A) - page 28

    28 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off burner system and let cool before ser- vicing. Only a qualified service person should service and repair burner system or stove. CAUTION: Never use a wire, needle, or similar object ...

  • Vanguard Heating SDVBP(A) - page 29

    29 105499 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Burner system produces a whistling noise when burner is lit Glass soots Burner system produces a clicking/ticking noise just after burners are lit or shut off ...

  • Vanguard Heating SDVBP(A) - page 30

    30 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppl ...

  • Vanguard Heating SDVBP(A) - page 31

    31 105499 OWNER’S MANUAL SER VICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • burner system will not produce speci- fied heat • propane/LP gas supply might be low (propane/LP units only) When Gas Quality Is Bad • pilot will not stay lit • burners will produce flames and soot • ...

  • Vanguard Heating SDVBP(A) - page 32

    32 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) SPECIFICA TIONS SDVBN(A) SDVBP(A) 16,000-22,000 Btu/h 14,000-20,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. Thermal Efficiency 70% 70% Dimension, Inches/mm ...

  • Vanguard Heating SDVBP(A) - page 33

    33 105499 OWNER’S MANUAL ACCESSORIES Purchase these stove and burner system accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800- 432-2382. for information. You can also write to the address listed on the back page of this manual. WALL MOUNTED THERMOSTAT CONTROL KIT GW ...

  • Vanguard Heating SDVBP(A) - page 34

    34 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) ILLUSTRA TED PA R T S BREAKDOWN SDVBN(A) SDVBP(A) L O H I P I L O T OFF ON 24 27 19 20 21 23 26-1 26-4 26-2 26-3 29 30 4 25 1 2 4 4 7 8 9 10 11 13 12 31 15 16 17 18 22 22 28 5 32 3 14 6 ...

  • Vanguard Heating SDVBP(A) - page 35

    35 105499 OWNER’S MANUAL KEY NO. PART NUMBER DESCRIPTION QTY. 1 105478-01BR Firebox Assembly 1 2 M11084-26 Screw, Hex 2 3 105482-01CK Rear Cover 1 4 M11084-39 Screw, Hex 12 5 103587-02CK Switch Plate 1 6 099998-01 On/Off Switch 1 7 103284-04 Wire Harness 1 8 104491-01 Relief Cover 1 9 104518-01 Relief Cover Gasket 1 10 104527-01 Relief Spring 2 1 ...

  • Vanguard Heating SDVBP(A) - page 36

    36 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) ILLUSTRA TED PA R T S BREAKDOWN AMITY™ SCIVF(*) SERIES PSCIVF(*) SERIES (* Indicates Color Suffix Designation) 1 2 5 8 7-4 6 5 5 7-1 7-2 5 4 7-3 3 AMITY ™ STOVE CHASSIS ...

  • Vanguard Heating SDVBP(A) - page 37

    37 105499 OWNER’S MANUAL P ARTS LIST AMITY™ SCIVF(*) SERIES PSCIVF(*) SERIES (* Indicates Color Suffix Designation) This list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. * Included In Hardware Kit KEY PART NO. NO. DESCRIPTION QTY. 1 104171- ...

  • Vanguard Heating SDVBP(A) - page 38

    VANGUARD LIMITED WARRANTY DIRECT-VENT BURNER SYSTEM AND AMITY ™ STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions ...

Manufacturer Vanguard Heating Category Oven

Documents that we receive from a manufacturer of a Vanguard Heating SDVBP(A) can be divided into several groups. They are, among others:
- Vanguard Heating technical drawings
- SDVBP(A) manuals
- Vanguard Heating product data sheets
- information booklets
- or energy labels Vanguard Heating SDVBP(A)
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vanguard Heating SDVBP(A).

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vanguard Heating SDVBP(A), service manual, brief instructions and user manuals Vanguard Heating SDVBP(A). Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vanguard Heating SDVBP(A).

A complete manual for the device Vanguard Heating SDVBP(A), how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vanguard Heating SDVBP(A) by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vanguard Heating SDVBP(A).

A complete Vanguard Heating manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vanguard Heating SDVBP(A) - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vanguard Heating SDVBP(A), FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vanguard Heating SDVBP(A), that we can find in the current document
3. Tips how to use the basic functions of the device Vanguard Heating SDVBP(A) - which should help us in our first steps of using Vanguard Heating SDVBP(A)
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vanguard Heating SDVBP(A)
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vanguard Heating SDVBP(A) in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vanguard Heating SDVBP(A)?

Use the form below

If you did not solve your problem by using a manual Vanguard Heating SDVBP(A), ask a question using the form below. If a user had a similar problem with Vanguard Heating SDVBP(A) it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)