  • Metrologic MS9530 Series - page 1

    MS9530 Series Voyager® RF Single Line Hand-Held RF Bar Code Scanner Installation and User’s Guide PRELIMINARY MS9530 Voyager RF Printed: September 2002 Version: 1.1 Status: Approved 1 ...

  • Metrologic MS9530 Series - page 2

    Table of Contents Voyager RF Scanne r – Over view ............................................................ 3 Base Stat ion.............................................................................................. 4 Unpacking List.......................................................................................... 5 Connecting the Bas ...

  • Metrologic MS9530 Series - page 3

    Product Overview The MS9530 Series Voyager RF is a wireless single line hand-held scanner with one bi-directional RF channel radio which provides about 20-30 meters portability. It has got a battery pack which can be removed from the unit to be charged through a Wall-Power supply in about 110 min. No charging stand is required. Once charged the uni ...

  • Metrologic MS9530 Series - page 4

    BASE STATION The Base Station is a interface decoder to which the Voyager is connected via a virtual RS232 port. Its func tion is to receive RF data from Voyager RF and transmit it to the Host. Therefore, all the standar d features that can be used when connecting a RS232 device to a Base Station, as explained in the Base Station Configuration Guid ...

  • Metrologic MS9530 Series - page 5

    UNPACKING LIST The kit is packed accordi ng to its functionality: Transmitter: • Voyager RF: Reader + Battery Pack • Wall-Power Supply for Battery Pack charging • Voyager RF Configuration Manual • Voyager RF installation and User guide Base Station: • Base Station • Base Station Manual • For Wedge interface: 1. Cable Y-XX 2. Power Sup ...

  • Metrologic MS9530 Series - page 6

    CONNECTING THE BASE STATION TO THE HOST WEDGE INTERFACE 1. Turn off the Host system 2. Connect the cable Y-XX between the keyboard and Host 3. When Power supply required (it is recommended all the times for better RF transmissions), check that the voltage matches the AC outlet and then connect 4. Power up the Host system RS232 INTERFACE 1. Turn off ...

  • Metrologic MS9530 Series - page 7

    LINKING THE VOYAGER RF TO THE BASE STATION This section explains how to link the Vo yager RF to the Base Station. It is supposed that the software is already loaded into the unit and that the Base Station is configured with its own serial number. • Power ON the Base Station • Insert Battery Pack and press CodeGate button to power ON the unit. ? ...

  • Metrologic MS9530 Series - page 8

    • Read Fix Serial RF Number barcode to load Base Station's serial number into the Voyager. • Read Base Station Serial Number barcode. (located on the Base Station). • Read Enter/Exit Configuration Mode barcode. • After reading this barcode the Voyager will try to link the Base Station. Now a linki ng should be performed. At this moment ...

  • Metrologic MS9530 Series - page 9

    FIXING VOYAGER RF ID NUMBERS This section explains how to fix an Identifier number to each Voyager RF. Basically, each Base Station can work with up to 5 VoyagerRF’s at the same time. To enable this facility, an Identif ier Number (ID) mu st be configured to each Voyager RF. By reading RF De faults, ID=1 is configured. There cannot be more than o ...

  • Metrologic MS9530 Series - page 10

    The system is ready to work. Please note again, that each time a Voyager RF is activated, it indicates its ID number just before linking with Base Station with steady RED and GREEN LED’s whilst the YELLOW LED flashes an appropriate number of times in relation to its ID number. Ie; one YELLOW led flash means ID=1 and 5 YELLOW LED flashes would ind ...

  • Metrologic MS9530 Series - page 11

    BASE STATION TESTING BARCODE The Base Station will accept all data fr om Voyager RF where the Base Serial Number is “0000000000”. Use this Test Barcode as Base Serial Number when programming the Voyager RF Serial Number to fix t he Voyager RF in test Mode. This Barcode is for testing purpose s and should NEVER can be considered as functional Ba ...

  • Metrologic MS9530 Series - page 12

    BATTERY PACK In order to charge the Batte ry Pack, there is no need to use a cradle. It can be re-charged when disconnected from the sca nner with the Voyager RF 5V, 1.5A Wall Power Supply. The Battery Pack can’t be recharged while inserted into the Voyager. Therefore it is recommended that two battery packs are used. One can be in use with the s ...

  • Metrologic MS9530 Series - page 13

    Standby mode will discharge the battery pac k in around 5 days. The number of readings will naturally decreas e as the standby time incr eases. To avoid having low battery messages appearing, it is recommended that the battery pack is disconnected from the sc anner when not in use over an extended period of time. MS9530 Voyager RF Printed: Septembe ...

  • Metrologic MS9530 Series - page 14

    VISUAL INDICATORS The scanner has RED and GREEN LED’s. When the scanner is on, these visual indicators show the st ate of the scanner functionality. Start Up Sequence From Stand-by, once the user presses Co deGate button, the scanner goes into start-up mode. Whilst in this mode, the YELLOW LED is displayed. 1. The scanner starts checking its OS ( ...

  • Metrologic MS9530 Series - page 15

    Low Battery Message When the battery starts to loose its c harge, the scanner detects it and makes a Razzberry sound every time a new r eading is performed. The YELLOW, RED and GREEN LED’s will also flash alternatively. However, the Voyager RF will continue to operate. The operator should, at this point, re move the battery pack and recharge it. ...

  • Metrologic MS9530 Series - page 16

    PROGRAMING MODES Voyager RF can be programmed vi a Barcodes. Use Metrologic’s MetroSelect Single Line Configuration Guide to configure the unit. This configuration guide is common to all Voyagers. When using Voyager RF, this one should be used and the following sections of the Single Line Configuration Guide should be avoided: RS-232, Keyboard, O ...

  • Metrologic MS9530 Series - page 17

    MetroSet It is possible to download/upload se ttings from MetroSet 2 (PC based software) to each Voyager RF by radio. In order to do that, read t he MetroSet RF barcode with the Voyager RF that you want to work with and follow MetroSet RF instructions. Always read this barcode before runni ng the MetroSet RF upload/download commands. Keep the Voyag ...

  • Metrologic MS9530 Series - page 18

    SOFTWARE VERSION It is possible to find out the software of Voyager RF as well as the Base Station to which the unit is linked with. Scanning the following barcode, the Base Station will transmit the actual software revision with the following format: MI9530 BASE STATION: #50200, MA RCH 2002.| MS9530: BODY/OS #14655/50100 MS9530 Voyager RF Printed: ...

  • Metrologic MS9530 Series - page 19

    EML EML Handshake is a defined data formatting handshake that allows the Voyager RF to send and receive data from the Host System through the Base Station. To be able to use this f eature, the Ba se Station: • Must be connected via RS232 to the Host System using the M-01 cable • Must have EML feature activated (see Base Station’s manual to kn ...

  • Metrologic MS9530 Series - page 20

    MS9530 Voyager RF Printed: September 2002 Version: 1.1 Status: Approved 20 SPECIFICATIONS RF LINK SPECIFICATIONS Frequencies: 434 MHz Bandwidth: 2 x 75 kHz Modulation: FM RF Protocol: Two way data transmission, One channel. 39062.5 Baud speed. Output Power Voyager RF: <10 mw Output Power Base Station: 6 mw Operating Range: Up to 30 Mts. (Open Ai ...

Manufacturer Metrologic Category Scanner

Documents that we receive from a manufacturer of a Metrologic MS9530 Series can be divided into several groups. They are, among others:
- Metrologic technical drawings
- MS9530 Series manuals
- Metrologic product data sheets
- information booklets
- or energy labels Metrologic MS9530 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Metrologic MS9530 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Metrologic MS9530 Series, service manual, brief instructions and user manuals Metrologic MS9530 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Metrologic MS9530 Series.

A complete manual for the device Metrologic MS9530 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Metrologic MS9530 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Metrologic MS9530 Series.

A complete Metrologic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Metrologic MS9530 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Metrologic MS9530 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Metrologic MS9530 Series, that we can find in the current document
3. Tips how to use the basic functions of the device Metrologic MS9530 Series - which should help us in our first steps of using Metrologic MS9530 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Metrologic MS9530 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Metrologic MS9530 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Metrologic MS9530 Series?

Use the form below

If you did not solve your problem by using a manual Metrologic MS9530 Series, ask a question using the form below. If a user had a similar problem with Metrologic MS9530 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)