    USER GUIDE SCC-RL Y01 Relay Module The SCC-RLY01 contains on e single-pole double-thro w (SPDT) nonlatching relay capable of switching 5 A at 30 VDC when using an SC-2345 or SC-2350 , or 250 VAC when using an SCC-68. Any single E/M Series DAQ device digital input/output (P0) l ine 0 to 7 can control the SCC-RLY01. The SCC-RL Y01 uses positive logic ...

  • National Instruments Relay Module SCC-RLY01 - page 2

    SCC-RL Y01 Relay Module User Guide 2 ni.com bold Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. italic Italic text denotes variables, emphasis , a cross-reference, or an introduction to a key concept. Italic te xt also deno tes text that is a ...

  • National Instruments Relay Module SCC-RLY01 - page 3

    © National Instruments Corporation 3 SCC-RL Y01 Rel ay Module User Guide – Documentation for your hardware – Documentation for your software ❑ T o ols – 1/8 in. flathead scre wdri ver – Numbers 1 and 2 Phillips screwdriv ers – W ire insulation stripper Y ou can do wnload NI documents from ni.com/manuals . T o download the latest versio ...

  • National Instruments Relay Module SCC-RLY01 - page 4

    SCC-RL Y01 Relay Module User Guide 4 ni.com Figure 1. SCC-RL Y01 Circuit Diagram Caution When connecting signals >60 VDC to th e SCC-RL Y01 module in the SCC-68, you must use the high-voltage backshell. Figure 2 shows the high-voltage backshell. Figure 2. High-V oltage Backshell For information about how to conf igure the SCC-RL Y01 module w ith ...

  • National Instruments Relay Module SCC-RLY01 - page 5

    © National Instruments Corporation 5 SCC-RL Y01 Rel ay Module User Guide Caution The SCC-RL Y01 module is derated to 30 V maximum switching voltage in the SC-2345 carrier regardless of any other v oltage markings found on the SCC-RL Y01 module case. Signal bandwidth..................... .............. . DC to 400 Hz Contact resistance ..... ...... ...

  • National Instruments Relay Module SCC-RLY01 - page 6

    SCC-RL Y01 Relay Module User Guide 6 ni.com I/O connectors ............... .............. ............One 20-pin right-angle male connector One 3-pin screw-term inal block Field-wiring diameter ........... ......... .........28 to 16 AWG Maximum W orking Voltage Maximum working voltage refers to the signal voltage plus the common-mode vo ltage. Whe ...

  • National Instruments Relay Module SCC-RLY01 - page 7

    © National Instruments Corporation 7 SCC-RL Y01 Rel ay Module User Guide Safety This product meets the requirements of the follow ing standards of safety for electrical equipment for measurement, contro l, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications , refer to the product ...

  • National Instruments Relay Module SCC-RLY01 - page 8

    SCC-RL Y01 Relay Module User Guide 8 ni.com Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible man ner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional en viron mental information, refer ...

  • National Instruments Relay Module SCC-RLY01 - page 9

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e informat ion about Nationa l Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s. For patents covering Nati ...

Manufacturer National Instruments Category Switch

Documents that we receive from a manufacturer of a National Instruments Relay Module SCC-RLY01 can be divided into several groups. They are, among others:
- National Instruments technical drawings
- Relay Module SCC-RLY01 manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments Relay Module SCC-RLY01
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments Relay Module SCC-RLY01.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments Relay Module SCC-RLY01, service manual, brief instructions and user manuals National Instruments Relay Module SCC-RLY01. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments Relay Module SCC-RLY01.

A complete manual for the device National Instruments Relay Module SCC-RLY01, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments Relay Module SCC-RLY01 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments Relay Module SCC-RLY01.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments Relay Module SCC-RLY01 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments Relay Module SCC-RLY01, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments Relay Module SCC-RLY01, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments Relay Module SCC-RLY01 - which should help us in our first steps of using National Instruments Relay Module SCC-RLY01
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments Relay Module SCC-RLY01
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments Relay Module SCC-RLY01 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments Relay Module SCC-RLY01?

Use the form below

If you did not solve your problem by using a manual National Instruments Relay Module SCC-RLY01, ask a question using the form below. If a user had a similar problem with National Instruments Relay Module SCC-RLY01 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)