Manual Elinca BX 100

16 pages 0.47 mb
Download

Go to site of 16

Summary
  • Elinca BX 100 - page 1

    English Multivoltage 90/260V elinca sa switzerland www .elinchr om.com Operating Manual Elinca S.A Style BX 01.01.2007 ENG (73286) Printed in S wi tzerland Style BX 100/400 ...

  • Elinca BX 100 - page 2

    1 P .S: T echnical data subject to change. The listed values ar e guide values which may vary due to tolerances in components used. Introduction 2 Declaration of conformit y , disposal and recycling, CE marking 3 Safety notice and precaution 4 Operating instructions 5 Control P anel 6 Switch and Fuse 7 Modelling Light 8 Digital power display , Phot ...

  • Elinca BX 100 - page 3

    2 The quality of light and ex ceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area. T otally integrated to the r ange of the ELINCHROM ashes, the Style 100BX - 400BX units maintain t ...

  • Elinca BX 100 - page 4

    3 CE marking The shipped version of this device complies with the requirements of ECC dir ectives 89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage dir ective». Notational Conventions The meaning of the symbols and fonts used in this manual are as f ollows: Pa y particular attention to text marked with this symbol. F ailure ...

  • Elinca BX 100 - page 5

    4 • T ransport the ash unit with care and only in its original packaging or another corresponding packaging t to protect it against knocks and jolts. • T ransport only in complete discharged conditions. W ait a minimum 30 minutes after removing from mains supply befor e packaging and transportation. • Never drop the ash unit (danger ...

  • Elinca BX 100 - page 6

    5 3 1 6 11 12 The units Style BX (Multivoltage) are adapted f or operation on 90 - 260V/50 - 60Hz. Before connecting for the rst time, check to mak e sure that your Modelling lamp coincides with the voltage line. They must always be connected to an earthed ( gr ounded) mains supply . All Style BX units have a ba yonet mount and locking ring re? ...

  • Elinca BX 100 - page 7

    6 9 5 8 6 10 7 13 1 2 17 4 3 16 18 19 21 20 12 11 14 15 Overview of controls 1.Mains inlet socket 2.Mains fuse (slow blow) 3.Mains light up on/off switch 4.Modelling fuse (f ast blow) 5.Open-ash 6.Synchro-sockets, Amphenol + jack 3.5 mm 7 .Digital power display and charge/discharge indicator 8. Acoustic recharging signal (Beep) 9. Slave cell swi ...

  • Elinca BX 100 - page 8

    7 2 3 1 Mains fuse Modelling fuse Mains switch (Only tempered) Mains socket 4 8 A T 4 AF Mains Supply With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug of the original ELINCHROM mains cord into the mains socket (1). Mains Switch The switch should light up when the compact is switched on ("I" positio ...

  • Elinca BX 100 - page 9

    8 Modelling lamps and fuse for 90/140V Unit Modelling lamp Code Socket Fuse Code Style 100BX 150W halostar 23019 E27 4AF 19035 Style 400BX 150W halostar 23019 E27 4AF 19035 Option: 150W halogen 23031 GX 6,35 4AF 19035 Option: 200W halogen 23033 GX 6,35 4AF 19035 The touch pad (14) controls the modelling lamp on/off and the proportional light. Selec ...

  • Elinca BX 100 - page 10

    9 10 Photocell receptor 5 T est and ready 9 Cell Modellling light controls Power displa y The actual ash power is displayed in a f -stop compatible format. The power range is 5 f -stops. The digital display , provides continuous power indication of the ash and modelling lamp. The controls cov er a continuous output range from full power 1/1 t ...

  • Elinca BX 100 - page 11

    10 EL -Skyport triggers ashes without sync cords over a distance of approximately 100 m. Further detailed information please nd under : www .elinchrom.com / Products / RX Multi Remote Open ash "test" Having pressed the touch pad to release a ash, the green «READ Y» light will appear again once the unit is recharged. If the g ...

  • Elinca BX 100 - page 12

    11 If the unit does not ash but the ON/OFF switch indicates that there is power , it could be that the ash tube needs replacing. Note:Flash tubes (Swiss quality) have a long life with average use, but multiashing in long sequences can cause overheating of the electrodes leading to pr ematur e ageing, or perhaps the astube is br oken or ...

  • Elinca BX 100 - page 13

    12 Flash power J(Ws) 100 400 Power supply V 90/260 90/260 F-stop, 1m, 100 ISO , with reector 48° 32,5 64,5 Control range J(Ws) 5-100 25-400 Recycling time (230 V) s 0,2-0,5 0,3-1,1 Flash duration (t 0,5) 1/1 s 1/1700 1/850 (t 0,5) 1/16 s 1/1150 1/450 Modelling output W 150 150 V oltage across sync cable V 5 5 Connected load A/V A (W) 8/2080 8/2 ...

  • Elinca BX 100 - page 14

    13 code Reectors Wide angle ø 16 cm /90° 26143 Compact ø 18 cm /60° 26144 Standard ø 21 cm /50° 26141 Mini Soft ø 44 cm silver 26166 Mini Soft ø 44 cm white 26168 Snoot & Grid 26061 Grid for snoot 26427 Grids Grid set for reector 18 cm 26135 Grid set for 21 cm 26051 Filters Set of 10 color/mixed lters for 21 cm x 21 cm 26243 Po ...

  • Elinca BX 100 - page 15

    14 This ELINCHROM product will be repaired free of char ge by the vending agent if during a period of 24 months from date of purchase its working order is impaired thr ough a manufacturing or material defect. The fault y product should be immediately sent to the authorized dealer or ELINCA agent. This guarantee is not v alid for equipment which has ...

  • Elinca BX 100 - page 16

    www.elinchrom.com ...

Manufacturer Elinca Category Work Light

Documents that we receive from a manufacturer of a Elinca BX 100 can be divided into several groups. They are, among others:
- Elinca technical drawings
- BX 100 manuals
- Elinca product data sheets
- information booklets
- or energy labels Elinca BX 100
All of them are important, but the most important information from the point of view of use of the device are in the user manual Elinca BX 100.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Elinca BX 100, service manual, brief instructions and user manuals Elinca BX 100. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Elinca BX 100.

Similar manuals

A complete manual for the device Elinca BX 100, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Elinca BX 100 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Elinca BX 100.

A complete Elinca manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Elinca BX 100 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Elinca BX 100, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Elinca BX 100, that we can find in the current document
3. Tips how to use the basic functions of the device Elinca BX 100 - which should help us in our first steps of using Elinca BX 100
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Elinca BX 100
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Elinca BX 100 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Elinca BX 100?

Use the form below

If you did not solve your problem by using a manual Elinca BX 100, ask a question using the form below. If a user had a similar problem with Elinca BX 100 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)