    2EADALL)NSTRUCTIONSBEFORE)NSTALLINGANDOPERATINGTHISAPPLIANCE -/$%,:4/-3  )MPORTANT3AFETY.OTICE 5SE#AREAND)NSTALLATION'UIDE 2EADANDSAVETHESEINSTRUCTIONS W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. ...

  • Zephyr ZTO-M795 - page 2

    )MPORTANT3AFETY.OTICE 2EADANDSAVETHESEINSTRUCTIONS W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJUR Y TO PERSONS, OBSERVE THE FOLLOWING: a. Installation worka nd electrical wiring must be done by qualified person (s) in accordance with all applicable codes and standards. Including fire-rated construction. b. Sufficient ...

  • Zephyr ZTO-M795 - page 3

    CONTENTS INSTALLA TION Mount heights & clearance Ducting Specifications Electrical Mounting the hood EZ Anchors Ductless Conversion Carbon Filters 1 1,2,3 4 4 5,6 6 7 7 8 8 8,9 8,10 11 12 13 FEATURES & CONTROLS T ouch controls & features Advance display functions Filter change indicator Filter clean indicator MAINTENANCE Cleaning Lights ...

  • Zephyr ZTO-M795 - page 4

    !MINIMUMOFROUNDORX RECTANGULARDUCTMUSTBEUSEDTOMAINTAIN MAXIMUMAIRFLOWEFFICIENCY !LWAYSUSERIGIDTYPEMETALDUCTSONLY &LEXIBLEDUCTSCOULDRESTRICTAIRFLOWBYUPTO  !LSOUSECALCULATIONONRIGHT? ...

  • Zephyr ZTO-M795 - page 5

    INST ALLA TION 2 DUCTING NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape. Some Ducting Options: WARNING : FIRE HAZA ...

  • Zephyr ZTO-M795 - page 6

    INST ALLA TION DUCTING 6" to 3-1/4 x 10" elbow adaptor. Air Diverting Kit Air register Ductless Re-circulating option Ductless Re-circulating option Crawl space 3 ...

  • Zephyr ZTO-M795 - page 7

    INST ALLA TION SPECIFICATIONS ELECTRICAL Cable Lock WARNING: All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow Nati ...

  • Zephyr ZTO-M795 - page 8

    Mounting the Range Hood 1. Mark hood center on Center hood on wall. 2. Mark and Install Wall Mount Bracket to Wall. (For hollow drywall, use E-Z Anchors, please see next page) 3. Fasten hood onto Wall Mount Bracket with screws provided. INST ALLA TION INSTALLA TION 33-7/8" 31-7/8" 27-7/8" Wall Mount Bracket Wall Mount Bracket EZ ANCH ...

  • Zephyr ZTO-M795 - page 9

    INST ALLA TION INSTALLA TION EZ ANCHORS Tap EZ anchor tip into marked drywall locations, turn with screwdriver until seated flush. Note: Whenever possible, the hood should be secured to wall studs. Use EZ anchors provided only on hollow drywall applications (minimum drywall thickness ½”). If a stud or wood surface is present, fasten anchors with ...

  • Zephyr ZTO-M795 - page 10

    #ARBON&ILTERS2EQUIRED  0URCHASEDUCTLESS#HARCOAL&ILTERSAS FOLLOW  2EMOVEMETALFILTERSONHOOD#LIP CARBONFILTERSONTOEACHSLOTOPENING  2EINSTALLMETALFILTERS  4URNON&ILTER#HANGE)NDICATORON CONTROLPANEL REFERDETAILSPG? ...

  • Zephyr ZTO-M795 - page 11

    Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower starts up on speed level 3. Speed Selection The 6 speed levels are selected by pressing to decrease and to increase speed level. The display indicates level selected. Delay Off This is used for programmed shut down of blower and lights 15 minutes after the f ...

  • Zephyr ZTO-M795 - page 12

    FEA TURES & CONTROLS CONTROLS: FILTER CHANGE INDICA TOR (Carbon Filters) Filter Change Reminder (Carbon, if fitted): When your hood is installed as a 'Purifying' (Ductless Recirculating) unit, it is fitted with a set of Carbon Filters to purify exhaust and fumes from cooking, and re-circulates the air within the home. These Carbon Fil ...

  • Zephyr ZTO-M795 - page 13

    FEA TURES & CONTROLS CONTROLS: FILTER CLEAN INDICA TOR (Metal Filters) Filter Clean Reminder (Standard Metal Filters fitted) Whether your hood is installed as an Exhaust or Purifying unit, a set of metal filters are fitted by the factory. These Metal Filters are intended to filter out residue from cooking. It need not be replaced on a regular b ...

  • Zephyr ZTO-M795 - page 14

    -!).4%.!.#% #,%!.).' 3URFACE-AINTENANCE #LEANPERIODICALLYWITHHOTSOAPYWATERANDCLEANCOTTONCLOTH$ONOTUSECORROSIVEOR ABRASIVEDETERGENTEGCOMETPOWDERSCRUB%:/FFOVENCLEANERORSTEELWOOL SCORINGPADSWHICHWILLSCRATCHANDDAMA ...

  • Zephyr ZTO-M795 - page 15

    MAINTENANCE LIGHTS Make sure all power is turned off and bulbs are not hot. Carefully pry trim (w/ glass) off the socket module. Replacement bulb w/ 12V 20W type bulbs. Replacing Light Bulbs CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. 12 ...

  • Zephyr ZTO-M795 - page 16

    1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be fre ...

  • Zephyr ZTO-M795 - page 17

    4//"4!).3%26)#%5.$%27!22!.49 ORANY3ERVICE2ELATED1UESTIONSPLEASECALL  (AVEYOURPRODUCTPROOFOFPURCHASEWITHDATEREADYFORWARRANTYISSUES /RWRITETO :EPHYR#ORPORATION 3ERVICEAND7ARRANTYDEPARTMENT ? ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr ZTO-M795 can be divided into several groups. They are, among others:
- Zephyr technical drawings
- ZTO-M795 manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr ZTO-M795
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr ZTO-M795.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr ZTO-M795, service manual, brief instructions and user manuals Zephyr ZTO-M795. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr ZTO-M795.

Similar manuals

A complete manual for the device Zephyr ZTO-M795, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr ZTO-M795 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr ZTO-M795.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr ZTO-M795 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr ZTO-M795, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr ZTO-M795, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr ZTO-M795 - which should help us in our first steps of using Zephyr ZTO-M795
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr ZTO-M795
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr ZTO-M795 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr ZTO-M795?

Use the form below

If you did not solve your problem by using a manual Zephyr ZTO-M795, ask a question using the form below. If a user had a similar problem with Zephyr ZTO-M795 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)