Manual ACTiSYS RS232

18 pages 0.7 mb
Download

Go to site of 18

Summary
  • ACTiSYS RS232 - page 1

    The Wireless Connectivity Expert 48511 Warm Springs Blvd., Suite 206, Fremont, CA 94539, USA Tel: +1-510-490-8024 F ax: +1-510-623-7268 Web: http://www.actisys.com E-mail: irda-info@actisys.com ACT-BT5701S v2 Bluetooth RS232 Adapter Class 1 User’s Manual December 06, 2006 Version 2.0  Copyright 2005-2006 ACTiSYS Corporation All Rights Reserved ...

  • ACTiSYS RS232 - page 2

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual TABLE OF CONTENT REVISION HISTORY ................................................................................................ 3 1. OVERVIEW ................................................................................................................ 4 2. DRIVER REQUI REMENT ... ...

  • ACTiSYS RS232 - page 3

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual REVISION HISTORY Revision History Revision Date Comment 0.1 03/22/2006 • Initial draft version 1.0 03/28/2006 • Modified for configure parameter instructions & added more FAQ • Increased dongle name as ACT-BT5701SM for master • Added detail description for master and slave ...

  • ACTiSYS RS232 - page 4

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual  Copyright 2005-2006 ACTiSYS Corp. Page 4 of 18 ACTiSYS Confidential Information Dec 06, 2006 Version 2.0 1. OVERVIEW ACTiSYS Bluetooth RS232 adapter brings wireless Bluetooth technology to your RS232 serial equipment, allowing you to eliminate conventional cables. With a maximum ra ...

  • ACTiSYS RS232 - page 5

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 6. FEATURES ! Bluetooth embedded solution for RS232 cable replacement, applications such as industrial remote control devices. ! Configurable baud rate 1.2k ~1843.2k bps. ! True Plug-n-Play; no driver required. ! Customized features support for pairing mode, device name, PIN code. ! Sn ...

  • ACTiSYS RS232 - page 6

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 7.2 Null Modem Connection For Configuring Parameters Figure 2: Null Modem Connection For Configuring Parameters 7.3 Null Modem Connection For Normal Operation Figure 3: Null Modem Connection For Normal Operation  Copyright 2005-2006 ACTiSYS Corp. Page 6 of 18 ACTiSYS Confidential In ...

  • ACTiSYS RS232 - page 7

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 8. FACTORY SETTING PARAMETERS When using ACT-BT5701S v2 with your serial devices, make sure all the settings match on both sides. Otherwise, you may encounter comm unicating problems. Below figure is the default factory setting parameters of this unit: NOTE: If it requires you to chang ...

  • ACTiSYS RS232 - page 8

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 9. CONFIGURATION PARAMETERS Figure 4: Configuration Parameters Window 9.1. UART Format • Baud Rate : 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600 or 1843200 bps selectable. • Data Bit : 5, 6, 7 and 8 data bits supported • Parity Check : None, Odd or ...

  • ACTiSYS RS232 - page 9

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual • Master or Slave Mode : User can select device as a master or a slave. If you configure it as a Master then you need to assign Slave BD address (Predefined Remote BD Address). If you configure it as a Slave, then there is a “Status” parameter selectable: “Discoverable” or ? ...

  • ACTiSYS RS232 - page 10

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual Figure 5: Null Modem Adapter Connect ACT-BT5701S v2 as shown in Figure 6. User has to take care of direction of DB9 null modem adapter. During configuring parameters, black end of null modem adapter should be connected to ACT-BT5701S v2. Please follow the instructions below: ! Connect ...

  • ACTiSYS RS232 - page 11

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual NOTE : For Normal Operation the null modem adapter must be in reverse direction. Black end should be connected to PC COM port while white end should be connected to ACT-BT5701S v2. Figure 7 shows this connection. Figure 7: Connection For Normal Operation 10.2. Insert the installation C ...

  • ACTiSYS RS232 - page 12

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 10.4. Then you will see the screen below. Click Finish to complete the procedure. 10.5. Now run utility program ACT-BT5701Sv2.EXE from Start>Programs> ACTiSYS> ACT- BT5701S v2 . You will see the following screen: Figure 8: Configuration Utility 10.6. Click “ Read Configurati ...

  • ACTiSYS RS232 - page 13

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual Figure 9: Read Configuration Complete  Copyright 2005-2006 ACTiSYS Corp. Page 13 of 18 ACTiSYS Confidential Information Dec 06, 2006 Version 2.0 ...

  • ACTiSYS RS232 - page 14

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 10.7. After all parameters have been set, click “ Write Configuration” button to save all the settings . See Figure 10. Figure 10: Write Configuration Progress 11. CONNECTION FOR NORMAL OPERATION For normal operation mode, the null modem adapter must be in reverse direction. Black ...

  • ACTiSYS RS232 - page 15

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 12. LED BEHAVIOR LED CATEGORY LED BEHAVIOR STATUS On Active (Connect) Mode Flash Fast Data Transfer Mode “ACT” LED Flash Slow Stand By Mode On Power on “POWER” LED Off Power off 13. ELECTRICAL CHARACTERISTICS AND SPECIFICATIONS 13.1 Electrical Characteristics Parameter Min Typi ...

  • ACTiSYS RS232 - page 16

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual 13.2 Generic Specifications FUNCTION ACT-BT5701S v2 Standard Bluetooth 1.2 Interface RS232 Configurable Parameters Master or Slave mode, Stop Bit, Parity Check, Baud Rate, Flow Control, BD address & all other parameters shown in Chapter 9 Modulation GFSK Spread Spectrum Frequency H ...

  • ACTiSYS RS232 - page 17

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual A8. User can give power to DC JACK pin through power adaptor 7.5V @300mA or give unregulated 5 ~ 12 VDC to pin 1 of the male connector of ACT-BT5701S v2. Q9. I am not able to configure the new parameters. A9. Please refer to Chapter 10 and strictly follow the sequence on connection of ...

  • ACTiSYS RS232 - page 18

    The Wireless Connectivity Expert ACT-BT5701S v2 User’s Manual  Copyright 2005-2006 ACTiSYS Corp. Page 18 of 18 16. CONTACT INFORMATION ACTiSYS Corporation 48511 Warm Springs Blvd, Suite 206 Fremont, CA 94539, USA TEL: +1-510-490-8024, FAX: +1-510-623-7268 E-Mail: irda-info@actisys.com Web: http://www.actisys.com ACTiSYS Confidential Informatio ...

Manufacturer ACTiSYS Category Network Card

Documents that we receive from a manufacturer of a ACTiSYS RS232 can be divided into several groups. They are, among others:
- ACTiSYS technical drawings
- RS232 manuals
- ACTiSYS product data sheets
- information booklets
- or energy labels ACTiSYS RS232
All of them are important, but the most important information from the point of view of use of the device are in the user manual ACTiSYS RS232.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ACTiSYS RS232, service manual, brief instructions and user manuals ACTiSYS RS232. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ACTiSYS RS232.

Similar manuals

A complete manual for the device ACTiSYS RS232, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ACTiSYS RS232 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ACTiSYS RS232.

A complete ACTiSYS manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ACTiSYS RS232 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ACTiSYS RS232, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ACTiSYS RS232, that we can find in the current document
3. Tips how to use the basic functions of the device ACTiSYS RS232 - which should help us in our first steps of using ACTiSYS RS232
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ACTiSYS RS232
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ACTiSYS RS232 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ACTiSYS RS232?

Use the form below

If you did not solve your problem by using a manual ACTiSYS RS232, ask a question using the form below. If a user had a similar problem with ACTiSYS RS232 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)