  • Generac 04758-1, 04759-1, 04760-1 - page 1

    GENERA C POWER SYSTEMS, INC. R R Installation and Owner’ s Man ual Air -cooled A utomatic Standb y Generators Models: 04758-1 (6 kW NG, 7 kW LP) 04759-1 (12 kW NG, 12 kW LP) 04760-1 (13 kW NG, 15 kW LP) DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y!! D ANGER Not intended f or use as Primary P o wer in place of utility or in life-support app ...

  • Generac 04758-1, 04759-1, 04760-1 - page 2

    I NTRODUCTION Thank you for purchasing this model by Generac P ower Systems Inc.. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-weather , metal enclo- sure that is ...

  • Generac 04758-1, 04759-1, 04760-1 - page 3

    T able of Cont ents Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 Introduction ........................Inside F ront Cover Read This Manual Thoroughly ........................IFC Contents ..........................................................IFC Operation and Maintenance ............................IFC How to Obtain Service ........ ...

  • Generac 04758-1, 04759-1, 04760-1 - page 4

    2 Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rule ...

  • Generac 04758-1, 04759-1, 04760-1 - page 5

    3 ELE CTR ICAL HA Z AR DS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, terminals, con- nections, etc., w ...

  • Generac 04758-1, 04759-1, 04760-1 - page 6

    Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup- plied with a weather protective enclosure that is in ...

  • Generac 04758-1, 04759-1, 04760-1 - page 7

    Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5 1.4 TH E GEN ER A T OR Control P anel Battery Compartment Fuel Inlet Air Filter Exhaust Enclosure Oil Filter Data Decal Fuel Regulator Oil Check/Fill Control Pan e l Air Filter Exhaust Enclosure Battery Compartment Fuel Inlet Oil Filter Oil Dipstick Data Dec ...

  • Generac 04758-1, 04759-1, 04760-1 - page 8

    6 Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.5 SP E CI F ICA TIONS 1.5.1 GEN ERA T OR Model 04758 Model 04759 Mo de l 04760 Rated Max. Continuous P ower Capacity (W atts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP† Rated V oltage 120/240 120/240 120/240 Rated Max. Continuous Load Cu ...

  • Generac 04758-1, 04759-1, 04760-1 - page 9

    7 1 . 6 FUE L RE QUIRE MEN T S AN D R E C OM M EN D A TIONS W ith LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resources Board for tamper -proof dua ...

  • Generac 04758-1, 04759-1, 04760-1 - page 10

    3. Remove the small hose clamp and hose from the fuel regulator . It may be necessary to pry the hose off of the brass fitting using a screw driver to gen- tly lift up the hose edge. 4. Remove the brass hose fitting screwed into the fuel regulator . 5. Locate and identify the brass idle jet. This will be located in the fuel regulator casting facing ...

  • Generac 04758-1, 04759-1, 04760-1 - page 11

    9 1.1 0 B A TTER Y INST ALLA TION Fill the battery with the proper electrolyte fluid if nec- essary and have the battery fully charged before installing it. Before installing and connecting the battery , complete the following steps: 1. Set the generator's A UTO/OFF/MANU AL switch to OFF . 2. T urn off utility power supply to the transfer swit ...

  • Generac 04758-1, 04759-1, 04760-1 - page 12

    10 The following procedur es are to be observed: • Wear full eye pr otection and protective clothing; • Where electr olyte contacts the skin, wash it of f immediately with water; • Where electr olyte contacts the eyes, immediately flush thoroughly with water and seek medical attention; and • Spilled electrolyte is to be washed down with an ...

  • Generac 04758-1, 04759-1, 04760-1 - page 13

    11 8. Connect an accurate AC voltmeter and a frequen- cy meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; fre- quency should read about 61-63 Hertz. 9. Connect the AC voltmeter test leads across termi- nal lug E1 and neutral; then across E2 and neu- tral. In both cases, voltage reading should be 121- 126 volts ...

  • Generac 04758-1, 04759-1, 04760-1 - page 14

    12 2.6 ADJ US TI NG TH E R E GU L A T OR (NA TUR AL GAS ONL Y) Although the generator has been factory set to pro- vide maximum power , it may be necessary in some areas to adjust this setting . Because natural gas has different BTU or power content across the country the engine may not perform as designed. If experiencing engine problems at high o ...

  • Generac 04758-1, 04759-1, 04760-1 - page 15

    13 Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Figure 2.3 — Engine Governor Adjustment 2.7 .2 1 2 KW AND 15 KW UN IT S 1. Loosen governor clamp bolt (See Figure 2.3). 2. Completely remove the idle spring . 3. W ith governor arm at wide open throttle position, rotate governor shaft fully clockwise. Tighten clamp ...

  • Generac 04758-1, 04759-1, 04760-1 - page 16

    14 Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 8. T urn ON the utility power supply to the transfer switch, which will allow the transfer switch to transfer back to utility power . The unit will con- tinue to run for one minute and then shut down. 9. Allow the unit to cool. 10. Drain the oil and remove the oil fi ...

  • Generac 04758-1, 04759-1, 04760-1 - page 17

    15 D . Utility V oltage Pickup Sensor • This sensor monitors utility power supply volt- age. When that voltage is restored to above 70 percent of the nominal source voltage, a retrans- fer time delay starts timing . E. Retransfer Time Delay • This timer runs for about 15 seconds. • At end of a 15- second delay , circuit board action de - ener ...

  • Generac 04758-1, 04759-1, 04760-1 - page 18

    16 3.6 SE T TI NG TH E EXERCISE TI M ER The generator is equipped with an exercise timer . Once it is set, the generator will start and exercise once every seven days, on the day of the week and at the time of day the following sequence is completed. During this exercise period, the unit runs for approx- imately 12 minutes and then shuts down. Tran ...

  • Generac 04758-1, 04759-1, 04760-1 - page 19

    17 4.1 F USE The generator panel’s 15 amp fuse (Figure 4.1) protects the DC control circuit against overload. The fuse is wired in series with the battery output lead to the panel. If the fuse element has melted open, the engine cannot crank or start. Replace the fuse using only an identical 15-amp replacement. The generator panel’s 5 amp fuse ...

  • Generac 04758-1, 04759-1, 04760-1 - page 20

    18 4.3.2 OI L CHANGE PROCEDU R E T o change the oil, proceed as follows: 1. Run the engine until it is thoroughly warmed up then shut OFF the engine. 2. Immediately after the engine shuts OFF , pull the oil drain hose (Figure 4.4) free of its retaining clip. Remove the cap from the hose and drain the oil into a suitable container . Figure 4.4 – O ...

  • Generac 04758-1, 04759-1, 04760-1 - page 21

    19 4.6 SP AR K P L UG(S) Reset the spark plug(s) gap or replace the spark plug(s) as necessary . See Section 4.13 for mainte- nance requirements. 1. Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plug(s) to ...

  • Generac 04758-1, 04759-1, 04760-1 - page 22

    20 4.8 ADJ US TI NG V AL VE CLEAR ANCE After the first 50 hours of operation, adjust the valve clearance in the engine. Important: If feeling uncomfortable about doing this procedure or the proper tools are not available, please contact the Generac Authorized dealer for service assis- tance. This is a very important step to insure longest life for ...

  • Generac 04758-1, 04759-1, 04760-1 - page 23

    21 4.1 0 A TTENTION AF TER S U B M ERSION If the generator has been submerged in water , it MUST NOT be started and operated. F ollowing any sub- mersion in water , have a Generac Authorized Dealer thor- oughly clean and dry the generator . 4.1 1 C OR ROSION P RO TECTION P eriodically wash and wax the enclosure using automo- tive type products. F r ...

  • Generac 04758-1, 04759-1, 04760-1 - page 24

    22 Section 4 — Maintenance Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by the nearest Generac Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Necessary M = Monthly * = Notify De ...

  • Generac 04758-1, 04759-1, 04760-1 - page 25

    23 Section 5 — T roubleshooting Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5.1 TROU B LE SHOO TI NG GU I DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown 1. Replace 15A fuse on generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables as necessary . 3. Defective st ...

  • Generac 04758-1, 04759-1, 04760-1 - page 26

    24 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) 0 CUS T O MER SU PPLIE D BLA CK BATTERY 12V L OP HT O 0 S P 2 S P 1 IM2 86 85 IM1 D D DIA G RAM KE Y D S W - P C B M OU NTED DIP S WIT CH ...

  • Generac 04758-1, 04759-1, 04760-1 - page 27

    25 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B C L OS E S T T O BEARIN G G R D 0 4 S TAT OR 1 94 224 224 22 5 1 5 224 17 4 22 5 224B 22 5 0 0 OU TP U T T O TRAN S FE R 22 22 MAN U A L F2 0 1 5A 66A 2 39 1 3 1 5 1 3 1 3 0 F1 1 5 17 17 V O LTA GE RE ...

  • Generac 04758-1, 04759-1, 04760-1 - page 28

    26 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B IM1 - IGNITION MODULE , CYLINDER # 1 IM2 - IGNITION MODULE , CYLINDER # 2 L O P - L O W O IL PRE SSU RE S WIT CH SP1 , SP2 - SPARK PLUG S S W1 - A U T O / O FF / MAN U AL S WIT CH S W2 - S ET ...

  • Generac 04758-1, 04759-1, 04760-1 - page 29

    27 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B 2 39 IM2 1 5 1 8 S P 2 24 0V IM1 0 1 94 17 1 5 2 3 1 5 2 39 S W 1 1 94 1 5A 22 11 2 3 11 22 11 S P 1 44 WINDIN G 12 0V 12 0V 33 NEUTRAL N2 N1 2 3 CUS T O ME R CO NNE C TI O N S 1 94 0 0 SC F ...

  • Generac 04758-1, 04759-1, 04760-1 - page 30

    TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) CB2 - CIRCUIT BREAKER , ALTERNATOR EXCITATIO N BLA CK CUS T O MER SU PPLIE D BATTERY 12V L OP HT O SP 86 85 IM D D S W - P C B M OU NTED DIP S WIT CH C B1 - MAIN OU TP U T BREAKE R BA - BR US H A SS EMBL Y B C R - BATTERY C HAR G E RELA Y D - DI O D E SC - S TARTER CO NTA C T OR I C T - ...

  • Generac 04758-1, 04759-1, 04760-1 - page 31

    29 0 4 C L OS E S T T O BEARI N G R D S TAT OR OU TP U T T O TRAN S FE R 24 0 V G ENERAT OR S WIT C H CO NTA C T OR 8 2 0 66A 1 94 1 5 0 66A 1 5A 2 39 2 3 1 5 1 5A F2 1 3A 1 3 0 1 3 F1 1 3 351 14 N2 0 22 4 22 5 0 351 1 3 224 4 0 22 5 14 N2 N1 1 3A N1 V O LTA GE RE GU LAT OR 0 66A 0 1 62 2 2 0 4 6 11 4 4 11 2 2 4 MAN U A L A U T O 1 7 1 5 S W 1 2 39 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 32

    CB1 - CIRCUIT BREAKER , MAIN OUTPU T HT O - HI G H O IL TEMPERAT U RE S WIT CH S W1 - A U T O / O FF / MAN U AL S WIT CH CB2 - CIRCUIT BREAKER , ALT. EXCITATIO N TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) B C R - BATTERY C HAR G E RELA Y BA - BR US H A SS EMBL Y F1 - F US E 1 5 AM P F2 - F US E 5 AM P S P - S PARK PL UG F S - F ...

  • Generac 04758-1, 04759-1, 04760-1 - page 33

    31 INP UT 12V dc U TILIT Y CO I L RELAY TRAN S FE R NE U TRA L 120 V 24 0 VA C CUS T O ME R SU PPLIE D 2 3 S W 1 2 39 C 1- 6 0 1 5 17 0 1 8 C 1- 5 0 1 8 0 17 56 1 8 14 1 5A 17 0 1 5 0 C 1- 1 56 2 39 1 3 1 5 SC 14 1 5A 1 94 2 3 1 5 IM 0 D BLA CK SP P O WE R WINDIN G ( STATOR ) F S 14 C 1- 2 1 94 22 RED SC SM 24 0V 44 11 C B 1 33 12 0V C 2- 5 N2 22 5 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 34

    32 2 3 36 24 37 4 9 35 2 6 4 6 4 9 2 4 3 4 9 4 3 32 34 1 8 50 7 4 35 25 51 1 5 4 8 21 1 90 91 93 1 3 42 39 1 0 3 93 2 5 35 14 88 54 9 8 27 35 1 49 4 9 11 50 1 6 17 1 5 47 1 9 12 6 31 44 30 2 9 2 8 87 86 41 4 0 55 57 56 58 52 49 20 52 72 60 44 62 64 66 59 71 69 68 71 68 69 38 7 3 7 5 4 6 7 4 76 82 77 80 82 7 9 80 81 4 8 44 85 84 72 91 63 92 4 9 PRE ...

  • Generac 04758-1, 04759-1, 04760-1 - page 35

    33 ITEM P ART NO .QTY . DESCRIPTION 1 0C6140 1 ASSEMBL Y , ENCLOSURE BASE 0D1901 1 ASSEMBL Y , ENCLOSURE BASE (7KW) 2 0C6735 2 SUPPORT , ROOF FOLDING 3 0C7061 1 ENCLOSURE, FRONT 4 0C7062 1 ENCLOSURE, EXHA UST SIDE 0C7062A 1 ENCLOSURE, EXHAUST SIDE (7KW) 5 0C7063 1 ENCLOSURE, SIDE & BA CK 0C7063A 1 ENCLOSURE, SIDE & BACK (7KW) 6 0C7064 1 ENC ...

  • Generac 04758-1, 04759-1, 04760-1 - page 36

    34 21 46 22 3 7 38 8,32 8, 9 27 44 47 10 13 15 35 17 49 14 15 5 16 23 38 4 5 48 2 29 21 17 16 4 6 7 49 23 27 42 12 45 44 20 40 11 1 43 15 35 14 3 41 24 45 47 47 45 3 1 33 14 13 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Control Panel – Drawing No. 0E7 97 4 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 37

    35 ITEM P ART NO . QTY . DESCRIPTION 1 0E7886A 1 CIRCUIT BREAKER 30A X 2P 240V (7KW) 0E7886C 1 CIRCUIT BREAKER 40A X 2P 240V (8.5KW) 0E7886E 1 CIRCUIT BREAKER 50A X 2P 240V (12KW) 0E7886F 1 CIRCUIT BREAKER 60A X 2P 240V (13KW) 0E7886G 1 CIRCUIT BREAKER 70A X 2P 240V (15KW) 2 0A1801 1 ASSEMBL Y , BA TTER Y CHARGER ENGINE 3 083049 1 ASSEMBL Y , PO TT ...

  • Generac 04758-1, 04759-1, 04760-1 - page 38

    36 17 15 18 2 22 14 13 12 9 7 24 3 27 29 28 32 19 23 6 5 65 6 4 63 6 1 60 59 58 5 2 5 1 50 49 48 47 46 45 44 43 57 1 42 41 38 3 7 36 35 3 4 33 39 3 40 2 3 26 10 4 3 4 25 11 30 20 66 2, 5 , 19 , 20 , 39 , 40 , 47 , 64 , 93 , 140 3, 32 , 33 , 34 , 35 , 36 , 40 , 72 73 1 4 0 16A 16 B 16 A 5 4 53 56 Section 7 — Exploded Views and P arts Lists Guardia ...

  • Generac 04758-1, 04759-1, 04760-1 - page 39

    37 ITEM P ART NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0C3008 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 8 SCREW , T APTITE M6-1.0 X 12 YC 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0E3372B 1 SEP ARA TOR, OIL BREA THER 7 0D8067A 1 ASSEMBL Y , HEAD #1 G&S 8 071983 4 RET AINER, PISTON PI ...

  • Generac 04758-1, 04759-1, 04760-1 - page 40

    38 112 112 111 1 1 07 1 06 1 05 1 04 1 03 1 02 1 09 99 92 95 96 91 89 90 89 88 86 85 83 84 82 81 1 30 99 11 8 12 6 94 7 9 7 8 7 6 77 7 5 74 122 12 5 12 3 12 5 11 9 12 0 1 37 1 36 1 34 1 33 1 32 127 2 9 1 35 11 3 1 01 11 0 121 112 12 8 124 24 80 87 98 97 1 38 1 39 1 1 116 141 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 41

    39 ITEM P ART NO . QTY . DESCRIPTION 74 0C5136A 2 KNOB, AIR CLEANER 75 0C3024 1 CO VER, AIRBO X NG/LP 76 0C3040 1 PRE-CLEANER, 77 0C8127 1 ELEMENT , AIR CLEANER 78 0D8564A 1 ASSEMBL Y , MIXER/AIRBO X 990 0D8564B 1 ASSEMBL Y , MIXER/AIRBO X 760 79 0D2595 4 SCREW SHOULDER (8MM) M6-1.0 X 18 80 0D4417 4 W ASHER,R UBBER 1/4" X 1/8" THICK 81 0C ...

  • Generac 04758-1, 04759-1, 04760-1 - page 42

    40 3 7 6 51 7 8 21 53 9 3 2 1 4 5 23 11 3 1 3 1 12 5 22 14 20 38 15 3 0 24 26 32 10 19 16 28 27 17 10 1 28 3 1 3 2 17 3 2 3 1 33 28 13 39 18 4 0 28 3 4 35 3 4 44 48 30 45 46 3 4 36 47 5 2 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-C ...

  • Generac 04758-1, 04759-1, 04760-1 - page 43

    41 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-C ITEM P ART NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C9935H 1 ST A TOR 3 0C9934H 1 RO TOR 4 0C6043A 1 CARRIER, REAR BEARING 5 0C8096 1 F AN, 8" CUR VED BLADE 6 0C9593 1 MUFFLER 7 0D3220 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 44

    42 29 3 4 11 2 5 24 43 21 7 13 33 12 38 17 3 2 3 1 28 3 1 20 19 10 17 15 32 16 22 39 8 6 37 14 3 2 40 32 24 25 10 30 19 26 28 27 28 3 2 3 1 41 10 18 36 35 29 41 42 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-E ...

  • Generac 04758-1, 04759-1, 04760-1 - page 45

    43 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-E ITEM P ART NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C7930 1 ST A TOR 12KW 0D2359 ST A T OR 13KW / 15KW 3 0C7944 1 RO TOR 12KW 0D2356 R O T OR 13KW / 15KW 4 0C6043 1 CARRIER, R ...

  • Generac 04758-1, 04759-1, 04760-1 - page 46

    44 11 47 33 3 4 36 35 3 7 27 45 43 39 18 19 20 23 3 2 44 48 2 4 46 11 22 29 28 3 1 30 17 5 2 1 14 13 26 38 25 25 40 41 12 16 6 1 2 4 42 10 5 7 3 8 9 4 9 5 1 50 5 4 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0D35 39-F P art 1 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 47

    45 ITEM P ART NO . QTY . DESCRIPTION 1 071978 1 ASSEMBL Y , CONNECTING ROD 2 071980 1 PIN, PIST ON D20 3 021533 1 SET , PIST ON RING 90MM 4 0C5848 1 PIST ON, HC 5 071983 2 RET AINER, PIST ON PIN 20 6 0D4287 1 ASSEMBL Y , CRANKSHAFT GH410 SMALL T APER 7 0A7628 1 ARM, GO VERNOR RC45 8 078658 1 PIN, "R" GO VERNOR ARM 9 078659 2 W ASHER, GO V ...

  • Generac 04758-1, 04759-1, 04760-1 - page 48

    46 19 21 6 2 20 28 3 39 40 41 43 44 2 4 6 5 12 7 8 9 10 13 14 1 16 18 11 6 3 7 36 35 2 7 17 18 3 4 33 3 4 18 29 30 3 1 38 6 45 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0D35 39-F P art 2 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 49

    47 ITEM P ART NO . QTY . DESCRIPTION 1 0C1069 5 SCREW , T APTITE M6-1.0X8 YELLO W CHROME 2 0D2922 1 HOUSING, BLO WER 3 0C8435 1 TUBE, DIPSTICK 4 0C9997 1 GU ARD , F AN 5 088434 1 WRAPPER, BO TT OM 6 045756 11 SCREW , T APTITE M6-1X10 YELLO W CHROME 7 088433B 1 WRAPPER, T OP 8 0D9004A 1 ASSY , ST AR TER 9 059985 2 SCREW , SHC M8-1.25 X 45 G12.9 10 0 ...

  • Generac 04758-1, 04759-1, 04760-1 - page 50

    1 2 5 4 10 3 6 7 8 12 11 28 26 15 14 17 13 22 23 24 25 19 20 18 29 16 21 31 18 29 16 26 14 15 17 13 21 20 19 24 22 25 23 10 9 28 11 12 27 37 35 32 10 33 34 37 36 FOR GT 760 ENGINE ONLY 32 48 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Gas Regulator – Drawing No. 0D8 7 2 0-B ...

  • Generac 04758-1, 04759-1, 04760-1 - page 51

    49 ITEM P ART NO . QTY . DESCRIPTION 1 0D5694 1 CASTING, TWIN REGULA T OR HOUSING 2 0C5765 1 SOLENOID , TWIN REGULA T OR 3 0C4647 1 GASKET , SOLENOID 4 0C4680 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0C6070 1 SPRING-SOLENOID , PLUNGER 6 022985 4 W ASHER, FLA T #6 7 022264 4 W ASHER, LOCK M4 8 075475 4 SCREW PPHM M4-0.7 X 10 9 0C5760A 1 JET , GN 410 EN ...

  • Generac 04758-1, 04759-1, 04760-1 - page 52

    50 Section 8 — Mounting Dimensions Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Drawing No. 0D3 7 3 9-B T M6PEM-T M6P M6PEM PE REAR VIEW L EFT S IDE VIEW TRANSFER SWITCH R I G HT S IDE VIE W F R O NT VIEW AIR NTAKE ( IF SUPPLIED ) " D O N O T LIFT BY THE R OO F" L IFTIN G H O LE S 4- CO RNER S Ø 3 0.2mm [ Ø 1 .19" ] R ...

  • Generac 04758-1, 04759-1, 04760-1 - page 53

    51 Section 9 — Notes Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators ...

  • Generac 04758-1, 04759-1, 04760-1 - page 54

    52 Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators NOTE: This Emission Control W arranty Statement pertains to this product only IF the generator size is 15 kW or below . CALIFORNIA AND FEDERAL EMISSION CONTR OL W ARRANTY ST A TEMENT Y OUR W ARRANTY RIGHTS AND OBLIGA TIONS The California Air Resources Board (CARB) ...

  • Generac 04758-1, 04759-1, 04760-1 - page 55

    53 Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators EMISSION CONTROL SYSTEM W ARRANTY Emission Control System Warranty (ECS W arranty) for 1997 and later model year engines: (a) Applicability: This warranty shall apply to 1997 and later model year engines. The ECS Warranty Period shall begin on the date the new engi ...

  • Generac 04758-1, 04759-1, 04760-1 - page 56

    Part No. 0E8295 Revision 0 (10/08/03) Printed in U.S.A. Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GEN ERAC PO WER SY S TEMS S T AN D ARD "T WO YEAR" LIM ITED W ARR ANT Y FOR GUARDIAN “EM ERGENCY AUT OMA TIC ST ANDBY GENER A T ORS” F or a period of two years from the date of original sale, Genera ...

Manufacturer Generac Category Portable Generator

Documents that we receive from a manufacturer of a Generac 04758-1, 04759-1, 04760-1 can be divided into several groups. They are, among others:
- Generac technical drawings
- 04758-1, 04759-1, 04760-1 manuals
- Generac product data sheets
- information booklets
- or energy labels Generac 04758-1, 04759-1, 04760-1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Generac 04758-1, 04759-1, 04760-1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Generac 04758-1, 04759-1, 04760-1, service manual, brief instructions and user manuals Generac 04758-1, 04759-1, 04760-1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Generac 04758-1, 04759-1, 04760-1.

A complete manual for the device Generac 04758-1, 04759-1, 04760-1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Generac 04758-1, 04759-1, 04760-1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Generac 04758-1, 04759-1, 04760-1.

A complete Generac manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Generac 04758-1, 04759-1, 04760-1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Generac 04758-1, 04759-1, 04760-1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Generac 04758-1, 04759-1, 04760-1, that we can find in the current document
3. Tips how to use the basic functions of the device Generac 04758-1, 04759-1, 04760-1 - which should help us in our first steps of using Generac 04758-1, 04759-1, 04760-1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Generac 04758-1, 04759-1, 04760-1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Generac 04758-1, 04759-1, 04760-1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Generac 04758-1, 04759-1, 04760-1?

Use the form below

If you did not solve your problem by using a manual Generac 04758-1, 04759-1, 04760-1, ask a question using the form below. If a user had a similar problem with Generac 04758-1, 04759-1, 04760-1 it is likely that he will want to share the way to solve it.

Copy the text from the picture