    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 1 Overview HP StorageWorks Modular SAN Array 1000 The HP StorageWorks Modula r SAN Array 1000 is a 2 Gb Fibre Ch annel storage system designed fo r the entry- level to mid-ran ge Storage Area Network ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 2

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 2 MSA1000 Highlights High Levels of Performance, Scalability, and Functionality • Performa nce – The msa1000 and i ts components have bee n designed us ing the latest ind ustry standa rd 2 Gb int ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 3

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 3 Models msa1000, with 256 MB cache 201723-B22/ 3R-A4328-A A HP StorageWorks Modular SAN Array 1000 For Alpha Server Systems w/ OpenVMS and Tru64 UNIX msa1000 Control ler, with 256MB cach e 218231-B2 ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 4

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 4 MSA1000 Components With the followi ng components, yo ur sto rage capacity and performance c an be scal ed to new level s Modular SAN Array 1000 The 4U cabinet h ouses up t o fourteen 1 ” Univers ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 5

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 5 MSA1000 Components msa Hub 2/3 The HP StorageWo rks msa Hub 2/3 i s a low-c ost interco nnect designe d for cluste ring or low c ost, high s peed attachment of tw o servers to the msa1000, an e ntr ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 6

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 6 Service & Support, CarePaq and W arranty Information Storage Service Packages The Storage Servi ces Packagi ng takes the ex isting storag e product al ong with the existing s ervices and c reat ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 7

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 7 Service & Support, CarePaq and W arranty Information 9x5, Next Busin e ss Day, On-Site Coverage, 3 years FM-FCXHW- 36 103840-002 CarePaq Inf ormation Sample part numbers : 9x5, 4-H our Response ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 8

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 8 Configuration Informati on S TEP 1 – O RDER R EQ UIRE D I TEMS HP StorageWorks Modular SAN A rray 1000 201723-B22 Include s • (1) msa1000 Control ler with 256 MB cache • (1) MSA Fibre Ch anne ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 9

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 9 Configuration Informati on S TEP 2 – S ELECT O PTIONAL N ON -R EDUNDANT MSA 1000 S YSTEM O PTION S msa SAN Switch 2/ 8 (integrat ed) (Incl udes four 2Gb SFPs) 288247-B21 msa Hub 2/3 (i ntegrated) ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 10

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 10 Configuration Informati on S TEP 3 – C HOOSE R EDUNDANT MSA 1000 S YSTE M O PTIONS Redu ndant C onfigu rati on msa1000 Control ler 218231-B22 NOTE : Redund ant configu rations requir e two Host ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 11

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 11 Configuration Informati on S TEP 4 – C HOOSE S UPPORTED O PTIONS F OR 2 G B O R 1 G B I NFR ASTRUCTURE 2 Gb SFP SW Transceiv er Kit 221470-B21 2 Gb Fibre Channel Transceiver (SFP) 2 Gb Fibre Cha ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 12

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 12 Configuration Informati on S TEP 4 – C HOOSE S UPPORTED O PTIONS F OR 2 G B O R 1 G B I NFR ASTRUCTURE (c ontinued) 2 Gb Fibre Chann el HBAs FCA2354 Host Adapte r (Tru64 UNIX, OpenVMS ) 261329-B ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 13

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 13 Configuration Informati on S TEP 5 – C HOOSE H ARD D RIV ES & S TORAGE W ORKS E NCLOSURES (conti nued) StorageWorks Enclo sures The msa1000 cabine t holds fou rteen 1” Univ ersal Driv es. ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 14

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 14 Configuration Informati on C ONFIGURATION E XAM PL E S Two Node R e dundant C luster S olution Quantity Description Part Number 1 HP StorageWorks Modular SAN A rray 1000 201723-B22 1 msa1000 Contr ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 15

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 15 Technical Specifications M ODULAR SAN A RRAY 1000 LED In dicators on Fr ont (3) Power Fault detecte d in one or more sub- systems Fault in Enc losure Management Drive Acce ss ( centre) LED In dica ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 16

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 16 Technical Specifications M ODULAR SAN A RRAY 1000 C ONTROLLER User Interface Controller Displ ay with Stat us Indicators (2) and Push Buttons (4) Status Indicators on front of Controller (16) Elec ...

  • HP (Hewlett-Packard) SAN Array 1000 - page 17

    QuickSpecs hp St ora geWork s m odular SA N array 10 00 speci fic for Tru64 UNIX and Open VMS only DA-116 21 Canada — Versio n 2 — April 15 , 2003 17 Technical Specifications M ULTI -M OD E F IB RE C HANNEL C ABLES K ITS Cable Type LC-LC (2 Gb to 2 G b connecti ons) and L C-SC (2 Gb to 1 G b connecti ons) 50 Micro n multi-mo de fibre Available ...

Manufacturer HP (Hewlett-Packard) Category Computer Drive

Documents that we receive from a manufacturer of a HP (Hewlett-Packard) SAN Array 1000 can be divided into several groups. They are, among others:
- HP (Hewlett-Packard) technical drawings
- SAN Array 1000 manuals
- HP (Hewlett-Packard) product data sheets
- information booklets
- or energy labels HP (Hewlett-Packard) SAN Array 1000
All of them are important, but the most important information from the point of view of use of the device are in the user manual HP (Hewlett-Packard) SAN Array 1000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals HP (Hewlett-Packard) SAN Array 1000, service manual, brief instructions and user manuals HP (Hewlett-Packard) SAN Array 1000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product HP (Hewlett-Packard) SAN Array 1000.

A complete manual for the device HP (Hewlett-Packard) SAN Array 1000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use HP (Hewlett-Packard) SAN Array 1000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of HP (Hewlett-Packard) SAN Array 1000.

A complete HP (Hewlett-Packard) manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual HP (Hewlett-Packard) SAN Array 1000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the HP (Hewlett-Packard) SAN Array 1000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the HP (Hewlett-Packard) SAN Array 1000, that we can find in the current document
3. Tips how to use the basic functions of the device HP (Hewlett-Packard) SAN Array 1000 - which should help us in our first steps of using HP (Hewlett-Packard) SAN Array 1000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with HP (Hewlett-Packard) SAN Array 1000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of HP (Hewlett-Packard) SAN Array 1000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning HP (Hewlett-Packard) SAN Array 1000?

Use the form below

If you did not solve your problem by using a manual HP (Hewlett-Packard) SAN Array 1000, ask a question using the form below. If a user had a similar problem with HP (Hewlett-Packard) SAN Array 1000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)