Manual Taylor C300

48 pages 1.45 mb
Download

Go to site of 48

Summary
  • Taylor C300 - page 1

    OPERA T OR’S MANUAL Model C300 Slush Freezer Original Operating Instructions 055072 - M 9/26/ 08 (Or igi nal Publicat ion) (Updat ed 8/25/ 14) ...

  • Taylor C300 - page 2

    Com plete this page for quick r efere nce when ser vice is r equired: T aylor Distri butor: Address: Phone: Fax: E - mail: Serv ice: Par ts: Date of Installation: Infor mation found on the da ta label: Model Number: Seri al Number: Electrical S pecs: V oltage Cycle Phase Maximum Fuse Si ze: A Minimum Wi re Ampacity: A E 2008 Carrier Comm ercial Ref ...

  • Taylor C300 - page 3

    T able of Conte nts Model C3 00 T a ble of Contents Section 1 T o the Installer 1 ............................................ Section 2 T o the Operator 5 ........................................... Section 3 Sa fety 6 .................................................... Section 4 Op er ato r P arts Id entification 8 .............................. ...

  • Taylor C300 - page 4

    T able of Conte nts Mode l C30 0 T able of Contents - Page 2 Se ction 7 Im portant: Opera tor Checkli st 31 .............................. During Cl eaning and Sanitizing 31 ......................................... T roubleshooting Bacterial C ount 31 ........................................ Regular Maintenance Checks 31 .......................... ...

  • Taylor C300 - page 5

    1 Model C 30 0 T o the I nstaller 131210 Section 1 T o the Installer The f ollowing informat ion has been included in t he manual as saf ety and regulator y guidelines. For complet e installat ion instruc tions, pleas e see the Inst allation Check list. Installer Safety In all ar eas of the w orld, equipment should be installed i n accor dance with ...

  • Taylor C300 - page 6

    2 Model C 30 0 T o the I nstaller W ater Cooled Refriger ation Units (W ater Coo led Units Only) On t he back of t he unit, t wo additional 3/ 8” (9.5 m m) F .P . T . water connect ions for condenser inlet and outlet hav e been provided for eas y hook- up. 3/ 8” (9.5 m m) inside diam eter wat er lines should be connect ed to the m achine. F lex ...

  • Taylor C300 - page 7

    3 Model C 30 0 T o the I nstaller 131210 Electr ical Connectio ns In t he United St ates, t his equipment is int ended to be installed i n accordance wit h the National Elect rical Code (NEC), ANSI /NF P A 70- 1987. The purpose of t he NEC code is t he pract ical saf eguarding of pers ons and propert y from hazar ds arising f rom t he use of elect ...

  • Taylor C300 - page 8

    4 Model C 30 0 T o the I nstaller 090219 Initial F r eezin g Cylinder Cleanin g Due to t he types of products used in F CB equipment , it is imper ative t hat the f reezing cy linder and the inlet t ube be thoroughly br ush cleaned, rinsed, and s anitized bef ore running any produc t. Prepar e a cleaning solution, us ing 2 oz. of liquid detergent i ...

  • Taylor C300 - page 9

    5 Model C 30 0 T o the O pera tor 131210 Sec tion 2 T o the Opera tor The f reezer y ou have purchased has been car efully engineered and manuf actur ed to give you dependable operat ion. The M odel C300, when properly operat ed and cared for, will produce a cons istent qualit y product . Like all mechanic al products, this mac hine will require cl ...

  • Taylor C300 - page 10

    6 Model C 30 0 Safety 131210 Se ction 3 Sa fety We at T ay lor are concer ned about the s afety of t he operat or when he or she com es in contac t with t he fr eezer and its part s. T aylor has gone t o extrem e effort s to des ign and manufact ure built - in saf ety feat ures to pr otect bot h you and the s ervice technic ian. As an ex ample, war ...

  • Taylor C300 - page 11

    7 Model C 30 0 Safety 131210 S DO NOT allow unt rained personnel t o operat e this mac hine. S DO NOT operat e the f reezer unless all serv ice panels and ac cess doors are restrain ed with screws. S DO NOT rem ove any inter nal operating part s (example: fr eezer door , beater , scr aper blades, etc. ) unless all contr ol switc hes are in the O FF ...

  • Taylor C300 - page 12

    8 Model C 30 0 Op erator Part s Iden tif icati on 090417 Section 4 Operator Parts Identif ication Figur e 2 ITE M DESCRI PTION P ART NO. 1 PANEL A.- SIDE-LEFT C300 X54676-SER 2 PANEL-REAR 054672 3 PANEL-SI DE-RIGHT 054671 4 DISPLAY- LIGHTED 054683-27 5 PANEL-FRONT- UPPER 054669 6 PANEL-FRONT- SHELL 054668 ITE M DESCRI PTION P ART NO. 7 PANEL-FRONT- ...

  • Taylor C300 - page 13

    9 Mo del C300 Op erator P arts Id enti ficati on 140509 Beater Door A ssembly Figur e 3 ITEM DESCRIP TIO N P ART NO . 1 DOOR A.- FREEZER - SLUSH X80599 2 CAP- SPOUT - DOOR - FCB 046191- BLA 3 SPRING- COMP .480X.072X3. 0 039320 4 V AL VE- DRAW- DOOR - SLUSH 039324 *5 O- RING - 9/ 16 OD X .103W 016369 6 S P O U T -D O O R -F C B -B L A C K 046190 - B ...

  • Taylor C300 - page 14

    10 Mode l C30 0 Op erator P arts Id enti ficati on 140804 Accessor ies Figur e 4 ITE M DESCRI PTION P ART NO. 1 PAIL- 10 QT 013163 2 BRUSH A.- PACKAGE X64275 2a BRUSH-MI X PUMP BODY-3”X7” 023316 2b BRUSH-DOUBLE ENDED 013072 2c BRUSH-REAR BRG 1” DX2“L 013071 ITE M DESCRI PTION P ART NO. 2d BRUSH-DRAW VALVE 1- 1/2”OD 014753 3 KIT A. -TUNE U ...

  • Taylor C300 - page 15

    11 Model C3 00 Impor tant: T o the Opera tor Section 5 Important: T o the Operator Figur e 5 ITEM DESCRIP TIO N 1 Produc t Light - Lef t Side 2 Control S witch 3 Keypad - Left Side 4 Liquid Crys tal Display 5 Keypad - Right Side 6 Produc t Light - Right Side Contr ol Switch The cont rol swit ch is locat ed at the t op left cor ner of the cont rol c ...

  • Taylor C300 - page 16

    12 Model C3 00 Impor tant: T o the Opera tor Pres sing the AUTO ( - - > ) keys on bot h sides of t he unit will display this s creen. AUTO MODE AUTO OK SYRUP OK CO2 - OK W A TER - OK Line 1 indicat es the operat ing mode for eac h freez ing cylinder . Lin e 2 indicates the status of the syrup systems in each fr eezing cylinder. As long as s yrup ...

  • Taylor C300 - page 17

    13 Model C3 00 Impor tant: T o the Opera tor 2. BEA T ER OVERLOAD - Beat er motor is out on overload. W hen this fault occur s, the machine automat ically tur ns off. The f ault clears when the condit ion is corr ected. F AUL T DESCRIPTION L: BEA TER OVERLOAD R: BEA TER OVERLOAD C L R +++ S E L 3. CHK REFRIG SYS PSI - Compress or is out on high hea ...

  • Taylor C300 - page 18

    14 Model C3 00 Impor tant: T o the Opera tor 9. BRL NOT CO OLI NG - A fr eezing cylinder check has been es tablished f or the AUTO mode of operat ion. I f a fr eezing cylinder ent ers the AUTO m ode, the c ontrol will chec k product temper ature. Af ter fiv e m inutes, it will again check produc t temperat ure. If pr oduct tem perature does not dr ...

  • Taylor C300 - page 19

    15 Model C3 00 Impor tant: T o the Opera tor Repeat t he procedure f or the right side of t he unit. MANUAL DEFROST RIGHT SI DE YES NO < - - - - > SEL Note: O nly one side of t he unit may be placed in the D EFROST mo de at a gi ven tim e. Attemp ting to place a side of t he unit int o DEFRO ST while the other side is def rosting, will result ...

  • Taylor C300 - page 20

    16 Model C3 00 Impor tant: T o the Opera tor DE FRO ST TIM E RIGH T CYCLE 1 SUN 10:00 < - - - - > +++ - - - S E L Pre ss the MEN U (SEL ) ke y to retu rn to the OPERA TOR MENU. Screen F is CURRENT CO NDITI ONS. T hi s screen displays t he c urrent visc osity , product t emperatur e, and press ure for eac h freezing c ylinder . An asteri sk wi ...

  • Taylor C300 - page 21

    17 Model C3 00 Impor tant: T o the Opera tor Syr up Out Indicator AUTO MODE AUTO OUT SYRUP OK CO2 - OK W A TER - OK If t he word “O UT” appears in one of t he columns next t o the word “ SYRUP”, it indicates a lac k of syr up or syrup pr essure being supplied f or the indicated f reezing cy linder . I f the unit is in t he AUTO or PRIM E mo ...

  • Taylor C300 - page 22

    18 Model C 30 0 Op eratin g Proced ures 090417 Section 6 Operating Procedures The M odel C300 contains t wo 7 quart ( 6.6 liter ) freez ing cylinders. CAUTI ON: T his u ni t is p ressuriz ed wh en in oper ation. The cont rol switc h must be in t he OF F position unt il the unit is com pletely ass embled. No part should ev er be removed f rom t he m ...

  • Taylor C300 - page 23

    19 Model C 30 0 Op eratin g Proced ures 090417 Step 2 Lubricat e the inside diam eter of t he drive shaf t seal. Inst all the driv e shaft s eal bushing in the driv e shaft seal. Figur e 7 Note: T he drive shaf t bushing m ust be posit ioned in the c enter of t he drive s haft s eal. Step 3 Slide the s eal and bushing over t he shaft and gr oove un ...

  • Taylor C300 - page 24

    20 Model C 30 0 Op eratin g Proced ures Step 6 Align the f lats on t he end of t he beater ass embly with t he drive shaf t. M ake sure t he beater ass embly locating pin i s in position in t he locating hole of t he drive s haft. Turn the beat er slightly t o be certain t hat the beat er is proper ly seated. W hen in position, t he beater will be ...

  • Taylor C300 - page 25

    21 Model C 30 0 Op eratin g Proced ures Step 9 Snap the dr aw valve handle onto t he door spout . Align the hole in t he draw valve wit h the slot in the draw handle. Figur e 15 Step 10 Slide the piv ot pin thr ough the draw handle and int o the draw v alve. Plac e the draw handle slide ov er the opening in the draw handle and t he pivot pin. Figur ...

  • Taylor C300 - page 26

    22 Model C 30 0 Op eratin g Proced ures 090417 Step 15 Inst all the prim e plug. Figur e 21 Step 16 Place t he large o- ring into t he door groove and lightly lubric ate. Figur e 22 Note: E very four m onths or less, discard the o- r ings and ins tall new o- rings. Step 17 Inst all the f ront bearing. D o not lubr icate t he front bearing. Figur e ...

  • Taylor C300 - page 27

    23 Model C 30 0 Op eratin g Proced ures 080507 Sani tizing Note: I f a unit is sanit ized, and will not be used for an extended per iod of tim e, clean wat er should be used to f lush all sanit izer f rom the lines . Remove t he water f rom all the lines and components pr ior to stor age of the unit . Upon ret urn to s ervice, t he unit must be s a ...

  • Taylor C300 - page 28

    24 Model C 30 0 Op eratin g Proced ures Pres s the ME NU (SEL) k ey . Move t he cursor under t he word “SA NITI ZE” by press ing the OF F (< - - )key . RINSE / SANITI ZE RINSE SANITI ZE EXIT ----- < - - - - > SEL Step 7 Pres sing the MENU (S EL) key will giv e you the option f or sanitiz ing the left freezing c ylinder . M ove the curs ...

  • Taylor C300 - page 29

    25 Model C 30 0 Op eratin g Proced ures Prim ing/ Br ixing Step 1 Connect t he syrup line t o the Bag - in - B ox (BI B) syrup. Step 2 Remo ve t he d rip tray , splash shi eld and the lo wer fr ont panel to gain acc ess to t he syrup s ampling valve s. Step 3 Open t he prime plug. Figur e 32 Step 4 Place t he sampling valve in t he OF F (cent er) p ...

  • Taylor C300 - page 30

    26 Model C 30 0 Op eratin g Proced ures Step 7 Drain the pr oduct f rom the s yrup sampling v alve into a cup. Clos e the syr up sampling valve by t urning the handle to t he center pos ition. Figur e 36 Step 8 Stir t he finished pr oduct. Pour a s mall amount of product ov er the ref ract ometer . The brix r eading should regis ter 13 t o 14. A re ...

  • Taylor C300 - page 31

    27 Model C 30 0 Op eratin g Proced ures Note: T he position of the handle on the sy rup sampling v alve determ ines the direc tion of pr oduct flow . T he down position opens t he syrup sam pling valve f or collect ing brix samples . The c enter posit ion shuts off t he product f low . T he up position direc ts the f low of product to the f reezing ...

  • Taylor C300 - page 32

    28 Model C 30 0 Op eratin g Proced ures Dr aining Pr oduct From the Freez ing Cylinder Step 1 Wit h a pail beneath t he door spout, pr ess the BEA TER ( - - - ) key . This will allow the beat er to operat e and CO 2 pressur e will be maintained t o push the pr oduct f rom the f reezing cy linder . O pen the draw valv e and drain the produc t fr om ...

  • Taylor C300 - page 33

    29 Model C 30 0 Op eratin g Proced ures 080507 Cleaning Step 1 Prepar e an approved 100 PPM cleaning s olution (exam ples: 2- 1/2 gal. [9.5 liter s] of Kay - 5 R or 2 gal. [7. 6 lit ers] of St era - Sheen R ) in a c lean, empt y pail. USE WARM W A TE R AND FO LLOW T HE MANUF ACTURER ’S SPECIFICA TIONS. Imp ortan t: Make su re the cl eaner i s com ...

  • Taylor C300 - page 34

    30 Model C 30 0 Op eratin g Proced ures 080926 Br ush Cleaning Step 1 Prepar e an approved 100 PPM cleaning s olution (exam ples: 2- 1/2 gal. [9.5 liter s] of Kay - 5 R or 2 gal. [7. 6 lit ers] of St era - Sheen R ). USE WAR M W A TER A ND FOLLO W T HE MANUFACTURER’S SPECIFICA T IONS. IMP ORT ANT : Follow t he label direct ions. T oo STRO NG of a ...

  • Taylor C300 - page 35

    31 Model C3 00 Impor tant: Ope rator C heck list 080926 Section 7 Important: Operator Checklist Dur ing Cleaning and S anitizi ng AL W A YS FOLLOW LOCAL HEAL TH CODES Cleaning and saniti zing schedules ar e governed by your S tate or local r egulatory agenc ies and must be followed acc ordingly . T he following chec k points should be st ressed dur ...

  • Taylor C300 - page 36

    32 Model C3 00 Impor tant: Ope rator C heck list Winter Stor age If t he place of bus iness is t o be closed during t he winter mont hs, it is import ant to protect t he freezer by following c ertain prec autions, par ticularly if t he building is subjec t to f reezing condit ions. Disconnec t the f reezer f rom the m ain power sourc e to pr event ...

  • Taylor C300 - page 37

    33 Model C 30 0 T rouble shooting Guide Section 8 T roubleshooting Guide PROBL EM PROBABLE CAUSE REMEDY PA G E REF . 1. Product is t oo stiff . a. T oo muc h water t o syrup rat io. Improper br ix adjustm ent. a. Adjust the brix accor dingly . 25 b. Consist ency cont rol needs adjustm ent. b. Contac t a servic e technic ian. --- c. T or que couplin ...

  • Taylor C300 - page 38

    34 Model C 30 0 T rouble shooting Guide PROBL EM PROBABLE CAUSE REMEDY PA G E REF . 6. Unable to rem ove the drive s haft f rom the r ear shell bearing. a. Rounded corner s of hex end of dr ive shaft , drive coupling, or bot h. a. Replace t he drive shaf t, or call a servi ce technicia n t o replace t he direct dr ive unit. --- b. Lubricat ion of h ...

  • Taylor C300 - page 39

    35 Mo del C300 Parts Rep lacement S chedu le Section 9 Parts Replacement Schedule P ART DESCRIPTION EVERY 4 MONTHS EVERY 8 MONTHS ANNUALL Y Scr aper Blade X Drive S haft Seal X Drive Shaf t O - Ring X Fr eezer Door O - Ring X Draw V alve O - Ring X Door Spout O - Ring X Fr ont Bearing X Prime P lug O - Ring X Black Br istle Br ush, 1” x 2” Insp ...

  • Taylor C300 - page 40

    36 Model C30 0 Limited W arr anty on Equipme nt 131210 Section 10 L imited W a rranty on Equipment T A YL OR COM P ANY L IMI TED WARRANTY ON F REEZE RS T aylor Company , a div ision of Carr ier Commerc ial Refrigerat ion, I nc. (“ T ay lor”) is pleas ed to provide t his limit ed warrant y on new T aylor -branded fr eezer equipment available f r ...

  • Taylor C300 - page 41

    37 Mode l C30 0 Limite d W ar ranty on Equipment 3. Replac ement of wear it ems designated as Class “ 000” parts in the T ay lor Operat or ’s Manual. 4. E xternal hos es, elect rical power s upplies, and machine gr ounding. 5. P arts not s upplied or designated by T aylor , or dam ages resulting f rom their use. 6. Ret urn tr ips or waiting t ...

  • Taylor C300 - page 42

    38 Mode l C30 0 Li mited Warranty on Part s 131210 Section 1 1 Limit ed W arranty on Parts T A YL OR COM P ANY L IMI TED WARRANTY ON T A Y LOR G ENUINE P ARTS T aylor Com pany , a divis ion of Carrier Com mercial Ref rigeration, Inc. ( “T aylor” ) is pleased t o provide this lim ited warrant y on new T aylor genuine r eplacement c omponents and ...

  • Taylor C300 - page 43

    39 Mode l C30 0 Limite d W ar ranty on Part s LI MIT ED W ARRANT Y EXCEPT IO NS This limit ed warranty does not cover: 1. Labor or ot her cost s incurred for diagnos ing, repairing, r emoving, inst alling, shipping, s ervicing or handling of defect ive Parts , replacement Par ts, or new Parts . 2. Nor mal maintenanc e, cleaning and lubric ation as ...

  • Taylor C300 - page 44

    40 Mode l C30 0 Li mited Warranty on Part s LI MIT A T ION O F WARRANTY THI S LI MIT ED W ARRANTY I S EXCL USIVE AND I S IN L IEU O F ALL O THER WARRANTIE S, CO NDITI ONS AND/O R REMEDIE S UNDER THE LA W, INCL UDING ANY I MPLI ED W ARRANTI ES OR CO NDITI ONS O F MERCHANT ABIL IT Y OR F ITNES S FO R A P ARTI CULAR PURP OSE. T HE ORI GI NAL OW NER’ ...

  • Taylor C300 - page 45

    Mod e l C300 059540-27 05/14 Taylor Company 2014 Carrier Commercial Refrigeration, Inc. c YEL BLK YEL BLK RED/WHT STRIPE WHT PRP/WHT STRIPE WHT BLU/WHT STRIPE WHT ORG ORG/WHT STR. RED/BLK BLK LED BARREL 2 LED BARREL 1 RED/BLK STRIPE BLK BLK RED/BLK STRIPE BARREL 2 BARREL 1 BLK BLK BRN RED RED BARREL 2 BIB SWITCH THERMISTORS PROBES RIBBON CABLE SEE ...

  • Taylor C300 - page 46

    Mod e l C300 059540-33 05/14 Taylor Company 2014 Carrier Commercial Refrigeration, Inc. c YEL BLK YEL BLK RED/WHT WHT PRP/WHT WHT BLU/WHT WHT ORG ORG/WHT BRN RED/BLK BLK LED BARREL 2 LED BARREL 1 RED/BLK BLK BLK RED/BLK BARREL 2 BARREL 1 BLK BLK BRN RED RED BARREL 2 BIB SWITCH THERMISTORS PROBES RIBBON CABLE SEE NOTE 2 WHT/BLK BLK LCD DISPLAY RIBBO ...

  • Taylor C300 - page 47

    Mod e l C300 059540-40 05/14 Taylor Company 2014 Carrier Commercial Refrigeration, Inc. c YEL BLK YEL BLK RED/WHT WHT PRP/WHT WHT BLU/WHT WHT ORG ORG/WHT BRN RED/BLK BLK LED BARREL 2 LED BARREL 1 RED/BLK BLK BLK RED/BLK BARREL 2 BARREL 1 BLK BLK BRN RED RED BARREL 2 BIB SWITCH THERMISTORS PROBES RIBBON CABLE SEE NOTE 2 WHT/BLK STRIPE BLK LCD DISPLA ...

  • Taylor C300 - page 48

    Mod e l C300 059540-58 05/14 Taylor Company 2014 Carrier Commercial Refrigeration, Inc. c YEL BLK YEL BLK RED/WHT WHT PRP/WHT WHT BLU/WHT WHT ORG ORG/WHT BRN RED/BLK BLK LED BARREL 2 LED BARREL 1 RED/BLK BLK BLK RED/BLK BARREL 2 BARREL 1 BLK BLK BRN RED RED BARREL 2 BIB SWITCH THERMISTORS PROBES RIBBON CABLE SEE NOTE 2 WHT/BLK BLK LCD DISPLAY RIBBO ...

Manufacturer Taylor Category Freezer

Documents that we receive from a manufacturer of a Taylor C300 can be divided into several groups. They are, among others:
- Taylor technical drawings
- C300 manuals
- Taylor product data sheets
- information booklets
- or energy labels Taylor C300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Taylor C300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Taylor C300, service manual, brief instructions and user manuals Taylor C300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Taylor C300.

Similar manuals

A complete manual for the device Taylor C300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Taylor C300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Taylor C300.

A complete Taylor manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Taylor C300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Taylor C300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Taylor C300, that we can find in the current document
3. Tips how to use the basic functions of the device Taylor C300 - which should help us in our first steps of using Taylor C300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Taylor C300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Taylor C300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Taylor C300?

Use the form below

If you did not solve your problem by using a manual Taylor C300, ask a question using the form below. If a user had a similar problem with Taylor C300 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)