    IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-095 The Service Informatio n provides the fo llowing informa tion: • Precautions and safety inform ation • Specifications • Performance test procedure • Calibrati on and calibration adjustm ent procedure • Basic maintenance (cl eaning, replaci ng the battery) Form num ber: TM61095 Revision ...

  • IDEAL INDUSTRIES 61-095 - page 2

    TABLE OF CONTENTS Title Page # Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specifications 4 Resistance and C ontinuity Specifications 4 Current Specifications 4 Physical and environment characteristics 5 Certification and compliance 5 Required Equipm ent 6 Basic Maintenance ...

  • IDEAL INDUSTRIES 61-095 - page 3

    Page 1 Introduction Warning To avoid shock or injury, do not perform the verification tests or cali bration procedures described in this manual unless you are qualified to do so. The information provided in this document is for the use of qualified personnel only. Caution The 61-095 contains parts that can be damaged by static discharge. Follow the ...

  • IDEAL INDUSTRIES 61-095 - page 4

    Page 2 SAFETY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential h azards, use the product only as specified. CAUTION. These statements identify conditions or practices that cou ld result in damage to the equipment or other property. WARNING. These statement ...

  • IDEAL INDUSTRIES 61-095 - page 5

    Page 3 SPECIFICATIONS All specifications are warrant ed unless noted typical and appl y to the 61-095. Stated accuracies are at 23º C ± 5ºC at less than 80% relative humidity and without the battery indicator display ed. General specifications Characteristics Description LCD display digi ts 3 ½ Display count 2,000 Numeric update rat e 2.5 times ...

  • IDEAL INDUSTRIES 61-095 - page 6

    Page 4 Measurement Characteristics Accuracy is ±(% reading + num ber of digits) at 2 3ºC ± 5º C, less than 80% R .H. Voltage Function Range Accuracy Overload protection V 600 Vrms ± (1.5%+ 3 dgt) 40Hz ~ 500Hz 600 Vrm s V 600 V ± (1% + 2 dgt) Input impedance: 1M Ω // less than 100pF. Resistance & Continuity Function Range Accuracy Overlo ...

  • IDEAL INDUSTRIES 61-095 - page 7

    Page 5 Physical and Environmental Characteristi cs Physical Characteristics Description Dimensi ons (H x W x D) 188mm x 66mm x 42mm Weight (with battery) 0.3Kg Environmental Characteristics Description Temperature operating 0 to + 50º C Non-Operating -20 to + 60º C Humidit y (operating) < 80% R.H. Altitude Operating 2,000 m (6560 ft.) Non-Oper ...

  • IDEAL INDUSTRIES 61-095 - page 8

    Page 6 Required Equipment Required equipment is listed in Tab le B. If the recommended m odels are no t available, equ ipment with equivalent specifications m ay be used. Repairs or servicing s hould be perform ed only by qualified personnel. Table B. Required Equipment Equipment Required Characteristics Recommended Model Calibrator AC Voltage Rang ...

  • IDEAL INDUSTRIES 61-095 - page 9

    Page 7 Basic Maintenance Warning To avoid shock, remove the te st leads and any input signal s before opening the case or replacing the battery or fuses. Opening the Meter Case Caution To avoid unintentional short circu it, always place the uncovered meter assembly on a protective surface. When the case of the meter is open, circuit connections are ...

  • IDEAL INDUSTRIES 61-095 - page 10

    Page 8 Performance Tests The following perform ance tests verify the complete ope rability of the meter and check the accuracy of each meter function against the meter’s specifications. Accuracy specifications are valid for a period of one year after cali bration, when measured at an operat ing temp er atu re o f 18 ºC to 28ºC and at a maximum ...

  • IDEAL INDUSTRIES 61-095 - page 11

    Page 9 Testing the Resistance Function To verify the accuracy of the re sistance function, do the following: 1. Connect the calib rator to V Ω and COM on the meter. 2. Turn the rotary switch to Ω . 3. Apply the inputs for step 1-4 i n Table 3. 4. Compare the meter display readings to the display reading s in Table 3. 5. If the display reading f ...

  • IDEAL INDUSTRIES 61-095 - page 12

    Page 10 OK Figure 2 Top shows correct method; bo ttom shows incorrect method. Calibration Calibrate the meter once a year to ensure that it perform s according to specifications. Per fo rm ca lib ra tio n at an a mbi ent t empe ra tu re o f 23ºC ± 2ºC and relative humidity of 75% or less. Calibration for the Model 61-095: 1. Disconnect the test ...

  • IDEAL INDUSTRIES 61-095 - page 13

    Form number TM61095 Rev 2 September 2002 Page 11 Figure 3 - Calibration Adjustment Points ...

Manufacturer IDEAL INDUSTRIES Category Power Hammer

Documents that we receive from a manufacturer of a IDEAL INDUSTRIES 61-095 can be divided into several groups. They are, among others:
- IDEAL INDUSTRIES technical drawings
- 61-095 manuals
- IDEAL INDUSTRIES product data sheets
- information booklets
- or energy labels IDEAL INDUSTRIES 61-095
All of them are important, but the most important information from the point of view of use of the device are in the user manual IDEAL INDUSTRIES 61-095.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals IDEAL INDUSTRIES 61-095, service manual, brief instructions and user manuals IDEAL INDUSTRIES 61-095. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product IDEAL INDUSTRIES 61-095.

A complete manual for the device IDEAL INDUSTRIES 61-095, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use IDEAL INDUSTRIES 61-095 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of IDEAL INDUSTRIES 61-095.

A complete IDEAL INDUSTRIES manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual IDEAL INDUSTRIES 61-095 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the IDEAL INDUSTRIES 61-095, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the IDEAL INDUSTRIES 61-095, that we can find in the current document
3. Tips how to use the basic functions of the device IDEAL INDUSTRIES 61-095 - which should help us in our first steps of using IDEAL INDUSTRIES 61-095
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with IDEAL INDUSTRIES 61-095
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of IDEAL INDUSTRIES 61-095 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning IDEAL INDUSTRIES 61-095?

Use the form below

If you did not solve your problem by using a manual IDEAL INDUSTRIES 61-095, ask a question using the form below. If a user had a similar problem with IDEAL INDUSTRIES 61-095 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)