  • Beckett CF2500 - page 1

    COMMERCIAL PRODUCT S Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, quali fi ed service agency for installation, start-up or service work. ...

  • Beckett CF2500 - page 2

    2 Agency Approvals UL listed to comply with ANSI/UL296 and certi fi ed to CSA B140.0. Accepted by N.Y .C. M.E.A. Other approvals may be available and must be speci fi ed at time of order . ○ ○ ○ T o the Owner: Thank you for purchasing a Beckett burner for use with your heating appliance. Please pay attention to the Safety W arnings containe ...

  • Beckett CF2500 - page 3

    3 CF2500/CF3500 Burner Manual Hazard De fi nitions Owner ’ s Responsibility: Service Agency Responsibility: Section: General Information Indicates a hazardous situation which, if not avoided, will result in death or serious injury . Used with the safety alert symbol, indicates a hazardous situation, which, if not avoided, may result in minor or ...

  • Beckett CF2500 - page 4

    4 Pr e-installa tion Checklist Combustion Air Supply Fuel Supply Figure 1 – T ypical Nameplate The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or combustion air openings comply with National Fire Protection Standard for Oil-Burning Equipment, NFP A 31. For appliance/burner units in con ? ...

  • Beckett CF2500 - page 5

    5 CF2500/CF3500 Burner Manual The fuel unit nozzle port pressure is factory set at 300 psig. Some original equipment manufacturer burner applications may call for a lower pressure to obtain a required fi ring rate. Do not change this pressure unless directed to do so by the appliance manufacturer . Electrical Supply V erify that the power connecti ...

  • Beckett CF2500 - page 6

    6 Air T ube Combination Codes Model T ube Dimension T Dimension D Code Dimension E CF2500A/ CF2500 KP 6-3/4” 6-1/2” CF 66 KP 3-1/4” 10-1/4” 6-1/2” CF 102 KP 3-1/4” 13-3/4” 6-1/2” CF 136 KP 3-1/4” 17-3/4” 6-1/2” CF 176 KP 3-1/4” CF3500 KM 8” 8” CF 80 KM 4-1/2” 9-1/4” 8” CF 92 KM 4-1/2” 1 1-1/2” 8” CF 1 14 KM 4 ...

  • Beckett CF2500 - page 7

    7 CF2500/CF3500 Burner Manual T able 2 - Air T ube Capacity V ersus Firebox Pressure Maximum Firing Rate GPH Model T ube Firebox Pressure (In W .C.) No Reserve Air 10% T urndown (GPH) CF2500 & CF2500A KP 0.0 25.0 22.5 0.2 24.8 22.3 0.4 24.6 22.3 0.6 24.5 22.1 0.8 24.3 21.9 1.0 24.1 21.7 CF3500A KM/ KR 0.0 35.0 31.5 0.2 33.5 30.2 0.4 32.0 28.8 0 ...

  • Beckett CF2500 - page 8

    8 Mount Air T ube to Burner Remove the rear access door from the back of the burner for improved access to the interior . Attach the air tube to the burner with the bolts and acorn nuts provided. The acorn nuts must go on the outside of the burner , with the bolts inserted from the inside. Install Nozzle See Figure 5 . Install the oil nozzle in the ...

  • Beckett CF2500 - page 9

    9 CF2500/CF3500 Burner Manual Set Dimension Z Replace the rear access door on the burner , making sure that the adjusting plate assembly is now securely in the groove. Loosen acorn nut (item d ) in Figure 6 . Slide the nozzle line and plate assembly until dimension Z in Figure 6 is: CF2500A/CF2500 = 1-3/4 ±1/16” CF3500A (tube KM) = 2-5/8” ±1/ ...

  • Beckett CF2500 - page 10

    10 Connect Fuel Lines Fuel Unit By-pass Plug Oil Supply/Return Lines Install the oil tank and oil lines in accordance with all applicable codes. Size the oil supply and return lines using the guidelines given in the fuel unit literature included in the literature envelope. Oil line fl ow rate will equal the burner rate for one-pipe systems. For tw ...

  • Beckett CF2500 - page 11

    11 CF2500/CF3500 Burner Manual Figure 9 – One-pipe Oil Flow Figure 10 – T wo-pipe Oil Flow Legend ( Figures 9 & 10 ) a Return port b Pump outlet c Solenoid valve d Nozzle g Pump inlet k By-pass loop p Bleed port Nozzle Pressure – The fuel unit nozzle port pressure is factory set at 300 psig. Some original equipment manufacturer burner app ...

  • Beckett CF2500 - page 12

    12 W ir e the Bur ner Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. Wire the burner in compliance with all instructions provided by the appliance manufacturer . V erify operation of all controls in accordance with the appliance manufacturer ’s guidelines. See Figu ...

  • Beckett CF2500 - page 13

    13 CF2500/CF3500 Burner Manual 1 3 6 4 7 Standby 9 Pump Prime V alve-on Delay T rial for Ignition Lockout Ignition Carryover Relight Run Motor-Off Delay 5 2 8 Figure 12 - GeniSys 7505 Control with Optional Components T able 5 - 7505 Status Light Explanation Table Light Color On Continuously Flashing Red Restricted (Hard) Lockout Soft Lockout Green ...

  • Beckett CF2500 - page 14

    14 Figure 13 –T ypical Wiring (7505P) Section: Wire the Burner ...

  • Beckett CF2500 - page 15

    15 CF2500/CF3500 Burner Manual T ypical Burner Sequence of Operation - RM7897A Control When fi ring over 20 GPH the CF2500 and CF3500A will be supplied with a fl ame safeguard control. An air fl ow switch and low- fi re start relay will also be supplied. Consult local, state, and federal codes for burner requirements above 20GPH. Install the bu ...

  • Beckett CF2500 - page 16

    16 Pr epar e the Bur ner for Star t-up Section: Prepare the Burner for Start-up Professional Installation and Service Required Incorrect installation and mishandling of start-up could lead to equipment malfunction and result in asphyxiation, explosion or fi re. This burner must be installed and prepared for start- up by a quali fi ed service tech ...

  • Beckett CF2500 - page 17

    17 CF2500/CF3500 Burner Manual T able 6. Initial Indicator Adjustment Plate Settings for Head & Damper Tu b e Head Position Damper Position Approximate Head Setting Firing Rate (gph) Approximate Air Damper Setting Firing Rate (gph) KP (CF2500A / CF2500) 0- - 0 - - 1 -- 10 8.00 2 -- 20 9.00 3 17.00 30 1 1.00 4 17.50 40 12.00 5 18.00 50 15.00 6 1 ...

  • Beckett CF2500 - page 18

    18 Initial Air Settings If your burner was built for a speci fi c OEM application, the “Mfr ’s Settings” label (see Figure 1 ) will indicate the application and the initial air settings made at Beckett. Please verify those settings using the following procedure. If your burner was not built for a speci fi ed application, the following steps ...

  • Beckett CF2500 - page 19

    19 CF2500/CF3500 Burner Manual Star t the Bur ner Set Appliance Limit Controls Set the appliance limit controls in accordance with the appliance manufacturer ’s recommendations. Move the low- fi re hold switch (not shown) to the low fi re hold position. This will hold the burner in low fi re during initial start-up. Prepare the Fuel Unit for A ...

  • Beckett CF2500 - page 20

    20 number to reduce CO 2 by 2 percentage points at a zero smoke level. (Increase O 2 by 3 percentage points at a zero smoke level.) Example : Reduce CO 2 from 13.5% to 1 1.5%, with zero smoke (or increase O 2 from 2.5% to 5.5%). A margin of reserve air has been added to accommodate variable conditions. Check the breech draft pressure against the ap ...

  • Beckett CF2500 - page 21

    21 CF2500/CF3500 Burner Manual Annual Service — by quali fi ed service technician Replace the oil supply line fi lter . The line fi lter cartridge must be replaced to avoid contamination of the fuel unit and nozzle. Inspect the oil supply system. All fi ttings should be leak-tight. The supply lines should be free of water , sludge, and other ...

  • Beckett CF2500 - page 22

    22 R eplacement Par ts For best performance specify genuine Beckett replacement parts Item Description Description CF2500 Part No. CF3500 Part No. 1 Oil V alve Mounted on Junction Box 21789U 21789U 2 Knurled Nut All Models 3666 3666 3 Adjusting Plate Assembly w/ Stamped Sheet Metal Door 5201703U 5201703U 4 Fuel Pump J4P A-C10506 21529U 21529U 5 Dam ...

  • Beckett CF2500 - page 23

    23 CF2500/CF3500 Burner Manual 9 8 7 Figure 18 - Burner Replacement Parts 14 10 11 13 12 20 21 22 23 15 16 17 19 18 6 1 2 3 4 5 Figure 19 – Adjustable Mounting Plates Air T ube Model Flange A Flange B KP 51498 51630 KM 51498 51630 KR N/A 51631 Flange A Flange B ...

  • Beckett CF2500 - page 24

    USA: P .O. Box 1289 ● Elyria, Ohio 44036 Canada: R.W . Beckett Canada, Ltd. ● Unit #3, 430 Laird Road ● Guelph, Ontario N1G 3X7 www .beckettcorp.com Part Number 6104 BCF35 R14, Printed in the U.S.A. 09/10 The R. W . BECKETT CORPORA TION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorpo ...

Manufacturer Beckett Category Burner

Documents that we receive from a manufacturer of a Beckett CF2500 can be divided into several groups. They are, among others:
- Beckett technical drawings
- CF2500 manuals
- Beckett product data sheets
- information booklets
- or energy labels Beckett CF2500
All of them are important, but the most important information from the point of view of use of the device are in the user manual Beckett CF2500.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Beckett CF2500, service manual, brief instructions and user manuals Beckett CF2500. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Beckett CF2500.

Similar manuals

A complete manual for the device Beckett CF2500, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Beckett CF2500 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Beckett CF2500.

A complete Beckett manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Beckett CF2500 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Beckett CF2500, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Beckett CF2500, that we can find in the current document
3. Tips how to use the basic functions of the device Beckett CF2500 - which should help us in our first steps of using Beckett CF2500
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Beckett CF2500
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Beckett CF2500 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Beckett CF2500?

Use the form below

If you did not solve your problem by using a manual Beckett CF2500, ask a question using the form below. If a user had a similar problem with Beckett CF2500 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)