  • Bloomfield 8543 - page 1

    BLOOMFIELD INDUST RIES 2 ERIK CIRCLE , P . O. Box 280 V erdi , NV 8943 9 Cust omer Servi ce ( 775) 345 -0444 Ext .502 fax: (775) 345-0569 www .well sbl oomfi eld. com p/n 75804 Rev. (-) M611 011802 cps 611 OWNERS M A NUAL For MODUL A R BREWING SYSTEMS MODELS POUR OVER AUTOMATIC AUTOMATIC UNITS UNITS UNITS WITH FAUCET 8542 8541 8540 8543 8573 8572 8 ...

  • Bloomfield 8543 - page 2

    NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1. VISIBLE LOSS OR DAMAGE: Be certain that any vi ...

  • Bloomfield 8543 - page 3

    TABLE OF CONTENTS Thank You for purcha sing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life. This ma nual contains the information needed to properly install this appliance, and ...

  • Bloomfield 8543 - page 4

    FEATURES AND OPERATING CONTROLS Fig. 1 Fea tures & Operating Controls 2 ...

  • Bloomfield 8543 - page 5

    PRECAUTIONS AND GENERAL INFORMATION WA RNI NG: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WA RNI NG: Injury Hazard All installation procedu ...

  • Bloomfield 8543 - page 6

    INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST ARTING THE INST A LLA TIO N REFER TO EXPLODED VIEWS PAGES 18 thru 22 FOR COMPONENT NAMES/NUMBERS Unpack the unit. Inspec t all components fo r completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket (#33) and Spray Dis ...

  • Bloomfield 8543 - page 7

    INSTALLATION INSTRUCTIONS (contin ued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plumbin g codes and ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground. Electrical shock will cause de ...

  • Bloomfield 8543 - page 8

    OPERATION Fig. 4 Brewer Operation Diagram A. STAR T-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure spray disk and brew ga sket are properly installed in the brew head. ♦ Be sure the water supply is properly connecte d and the water supply valve is turned ON . ♦ Be sure the W ATER TANK IS ...

  • Bloomfield 8543 - page 9

    OPERAT ION (continu ed) WATER HEATER Water temperat ure is sensed by a thermobulb insert ed into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating elemen t. The setpoint temperature is adjustable at the therm ostat. The elem ent is prot ected fr om over- temperature by a hi -limit thermostat. ...

  • Bloomfield 8543 - page 10

    BREWING COFFEE CA UTI ON: Burn Hazard Exposed surfaces of the brewer, brew chamber and decanter m ay be HOT to the touch, and can cause serious burns. CA UTIO N: Burn Hazard To avoid splashing or over- flowing hot liquids, ALWAYS place an empty decanter under the brew chamber before starting the brew cycle. Failure to comply can cause serious burns ...

  • Bloomfield 8543 - page 11

    CLEANING INSTRUC TIONS PROCEDURE: Clean Coffee Brewe r PRECAUTIONS: Disconnect bre w er fro m electric power. Allow brewer to cool. FREQUENCY: Dail y TOOLS: Mild Detergent, Clean Sof t Cloth or Sponge Bristle Brush. 1. Disconnect brewer from electric power. Allo w brewer to cool before cleaning. 2. Remove and empty de ca nters. 3. Remove and empty ...

  • Bloomfield 8543 - page 12

    10 TROUBLESHOOTING SUGGESTI ONS SUGGESTED REMEDY Check po wer supply cord Check / reset circuit breaker Set for desired temperature Allow to cool Reset hi-limit (8786, 8788) Examin e w iring & connec tors, thermostat and heating element Repair/replace as needed Be sure to add sufficient water Increase wat er amount Adjust am ount of ground s Ad ...

  • Bloomfield 8543 - page 13

    SERVICING INSTRUCTIONS ACCESS PANELS Each warmer plate has a center stud which screws into a bracket. Remove warmer plates by turning counter-clockwise. Solenoid door is held by two screws and a retaining lip. Front Panel (In-Line Models) and To p / Rear Panel (3-Station Models): a. Remove warmer plate b y turning counter-clockwise until it unscre ...

  • Bloomfield 8543 - page 14

    SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid an d insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power. Place an empty decanter under brew chamber. Energize brewer and pour o ne decanter (6 4 oz.) of cold ...

  • Bloomfield 8543 - page 15

    SERVICING INSTRUCTIONS ( continued) IMPORTA NT: Water pressure must be betwee n 20 p.s.i and 90 p.s.i. flowing pressure. If wate r pressure e xceeds this value, or if water pressure varies g reatly, a pressu re regulator must be installed in the w ater s upply line. IMPORTA NT: Before se tting assembly into tank, make sure tank lid gasket is proper ...

  • Bloomfield 8543 - page 16

    SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer d rips continuously from brew head. Unplug power cord or turn circuit breaker OFF . Turn OFF and disconnect w ater supply from brewer inlet fitting. A. (OLD-STYLE) Remove hex nut holding inlet fitting into back of brewer. Remove t ...

  • Bloomfield 8543 - page 17

    SERVICING INSTRUCTI ONS (continued) IMPORTA NT: When replacing water faucet coil, also rep lace seal gaskets. NOTE : Any abrasion or roughness on the flat end of the seat cup will re quire replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem. Install a ne w seat cu p, making sure the k nob on t he stem is fully ...

  • Bloomfield 8543 - page 18

    CA UTION - CH EMICA L BU RN HA Z A RD Deliming chem icals are caustic. W ear appropriate pr otective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rmed by qualified and ex- perienced service personnel. IMPORT ANT: DO NOT spill, splash or pour water or deliming s ...

  • Bloomfield 8543 - page 19

    7. Set the tank back into the bre wer. Reassemble the tank lid to the water tank. Make sure the gask et is properly in place, then reinstall the hold-down strap. 8. Reinstall wiring to heating element and ther mostat. Reinstall the hi-limit thermostat (if removed). For brew ers with hot water faucet, reassemble fa ucet piping. Verify that all inter ...

  • Bloomfield 8543 - page 20

    EXPLODED VIEW & PARTS LIST CABINET & RELATED COMPONENTS 18 ...

  • Bloomfield 8543 - page 21

    EXPLODED VIEW & PARTS LIST (continued) 19 ITEM P A RT NO. DESCR IPTION USED ON 1 8700-16 W armer Cov er Plate, Black All 8875- 149 20 8543-23 T i nnerman Nut , #8 (not shown ) All 2 3 8 543 -6 9 H ey co B us hi ng Al l 33 854 3-42 S pr ay Head Gaske t All 34 827 27 S pray Dis k All 34a 854 3-45 S pr ay Head Retai ner All 35 857 2-34 Door , Sole ...

  • Bloomfield 8543 - page 22

    EXPLODED VIEW & PARTS LIST (continued) HOT WATER TANK ASSEMBLY 20 ITEM P ART NO. DESCRI PTION USED ON 13 8043-5 Hol d Down S trap All 50 8512- 51 Therm ostat Al l 52 8512-41 Seal Washer All 54 8043-12 T an k Cover Gasket All 56 8043-30 Seal G asket All 58 8540-6 Hot Water Coil 8540, 857 2, 8574 59 8043-8 Inl et Elbow All 60 8043-15 Vent Tube Al ...

  • Bloomfield 8543 - page 23

    ELECTRICAL COMPONENTS EXPLODED VIEW & PARTS LIST (continued) 21 2 8572-18 W armer Element, 120V 100W All 30 6710-23 W ar mer ON /OFF Switc h All 31 8572-24 B REW Sw itch, push-button 8572, 8573 , 8574 8707-55 B REW SWI TCH , momen tary rock er 8540, 8541 32 8718-31 R EADY TO BREW Indicator Light All 36 6407-15 C ord & Cap As semb ly , NEMA ...

  • Bloomfield 8543 - page 24

    EXPLODED VIEW & PARTS LIST (continued) INTERNAL PLUMBING COMPONENTS 22 ITEM P ART NO. DESCRIPTION USED ON 60 8043-15 V ent T ube All 61l 8 8540-3 Faucet Outlet T ub e As sembly 8540, 8572 & 8574 9 8540- 4 Formed Inlet T ube Assembly 8540, 8572 & 8574 10 8551-30 1/4“ Male Flare x 1/ 8 ” FPT 8540, 8572 & 8574 1 1 8514-26 N eedle V ...

  • Bloomfield 8543 - page 25

    WIRING DIAGRAMS 23 ...

  • Bloomfield 8543 - page 26

    WIRING DIAGRAM 24 ...

  • Bloomfield 8543 - page 27

    WIRING DIAGRAM (continued) 25 ...

  • Bloomfield 8543 - page 28

    Bloo mfield In dustri es, Inc. Divisi on of C arrier Refrig eratio n Blo om fiel d In dust ri es Canad a Li mi ted Divisi on of C arrier Refrig eratio n PO. Box 280 V erd i, NV . 894 39 T elephone ( 775)345-0 444 Fax (888)492-27 83 Service: (888)492-2782 website: ww w .wellsbloomfield.com 5850 Keaton Cr esent Mississauga, Ont ario , Canada L5R 3K 2 ...

Manufacturer Bloomfield Category Coffeemaker

Documents that we receive from a manufacturer of a Bloomfield 8543 can be divided into several groups. They are, among others:
- Bloomfield technical drawings
- 8543 manuals
- Bloomfield product data sheets
- information booklets
- or energy labels Bloomfield 8543
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bloomfield 8543.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bloomfield 8543, service manual, brief instructions and user manuals Bloomfield 8543. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bloomfield 8543.

Similar manuals

A complete manual for the device Bloomfield 8543, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bloomfield 8543 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bloomfield 8543.

A complete Bloomfield manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bloomfield 8543 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bloomfield 8543, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bloomfield 8543, that we can find in the current document
3. Tips how to use the basic functions of the device Bloomfield 8543 - which should help us in our first steps of using Bloomfield 8543
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bloomfield 8543
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bloomfield 8543 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bloomfield 8543?

Use the form below

If you did not solve your problem by using a manual Bloomfield 8543, ask a question using the form below. If a user had a similar problem with Bloomfield 8543 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)