    ASKING FOR ASSIST ANCE Rev A3 T echnical Support : T elephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 T echnical Support Hours: 8:00 AM - 5:00 PM Monday - Friday , Paci fi c T ime For 24 / 7 support, see the back of the product for the support number Write T o: Gefen, LLC c/o Customer Service 20600 Nordhoff St Chatsworth, CA 9131 1 www .g ...

  • Gefen GEF-3GSDI-16416 - page 3

    CONTENTS 1 Introduction 2 Operation Notes 3 Features 4 Panel Layout 4 Front Panel 5 Front Panel Descriptions 6 Panel Layout 6 Back Panel 7 Back Panel Descriptions 8 Connecting And Operating The 16x16 3GSDI Matrix 8 Wiring Diagram 9 The Standby Screen 9 Displaying the Firmware V ersion 9 Displaying the Boot Loader V ersion 10 Switching between RS-23 ...

  • Gefen GEF-3GSDI-16416 - page 4

    1 Congratulations on your purchase of the 16x16 3GSDI Matrix. Y our complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive computer and electronics add-on solutions that harness integration, extension, distribution and conversion technologies. Gefen’s reliable, plug-and-play products supplement cross-platform ...

  • Gefen GEF-3GSDI-16416 - page 5

    2 READ THESE NOTES BEFORE INST ALLING OR OPERA TING THE 16X16 3GSDI MA TRIX • There is no internal scaling in the 16x16 3GSDI Matrix. All of the attached monitors must be able to display the resolutions output by the source devices. For maximum compatibility it is recommended that only one compatible/common resolution be used by all of the source ...

  • Gefen GEF-3GSDI-16416 - page 6

    3 Features • Increases productivity • Supports resolutions up to 1080p, 1920x1200, and 2K. • Front panel control buttons for local switching. • Status LCD (shows routing status) • Serial interface for remote control via a computer or control automation devices supports RS-232 and RS-485 protocols. • IP Control • Discrete IR remote con ...

  • Gefen GEF-3GSDI-16416 - page 7

    4 Front Panel P ANEL LA YOUT 4 5 6 2 1 3 ...

  • Gefen GEF-3GSDI-16416 - page 8

    5 P ANEL DESCRIPTIONS Front Panel 1 LCD Display Displays the current routing status of the Matrix and is also used to manage source routing. 2 Power Switch T urn the power ON or OFF using this switch. 3 Control Buttons These buttons are used to navigate the LCD menu system. See pages 9 - 12 for more information. ◄ - Left ► - Right Select - Sele ...

  • Gefen GEF-3GSDI-16416 - page 9

    6 P ANEL LA YOUT Back Panel 4 5 8 9 6 1 3 2 7 ...

  • Gefen GEF-3GSDI-16416 - page 10

    7 P ANEL DESCRIPTIONS Back Panel 1 Reference In Connector Connect an external reference to this connector . Bi-level (black burst) and tri- level sync are supported. 2 3G-SDI Output Ports (1 - 16) Connect 3G-SDI monitors to these ports. 3 Grounding T erminal Provides a discharge path to ground in case a short circuit occurs between the “hot” le ...

  • Gefen GEF-3GSDI-16416 - page 11

    8 How to Connect the 16x16 3GSDI Matrix 1. Connect up to 16 3G-SDI source devices to the 3G-SDI inputs on the rear panel of the 16x16 3GSDI Matrix using SDI cables. 2. Connect up to 16 3G-SDI displays to the 3G-SDI outputs on the rear panel of the 16x16 3GSDI Matrix. 3. Connect the included power cord to the power input receptacle on the rear panel ...

  • Gefen GEF-3GSDI-16416 - page 12

    9 The Standby Screen The front panel of the 16x16 3GSDI Matrix has a 16 character 2 line LCD display . This display will shows the current routing status of the Matrix and will be used to perform routing commands and other operations. After the unit is powered on, the Standby Screen will be displayed: Displaying the Firmware V ersion Press the ◄ ...

  • Gefen GEF-3GSDI-16416 - page 13

    10 CONNECTING AND OPERA TING THE 16X16 3GSDI MA TRIX Switching between RS-232 and RS-485 Protocols Press the ► button to display the serial interface selection screen: Use the ◄ or ► buttons to switch between RS-232 and RS-485 serial protocols. The current selection is indicated by the cursor . In the example above, RS-232 is the currently se ...

  • Gefen GEF-3GSDI-16416 - page 14

    11 In the example below , TERMINA TION Of f has been selected. The LCD will now show that the RS-485 protocol has been selected, along with the termination- type: Press the Cancel button to return to the Standby Screen. CONNECTING AND OPERA TING THE 16X16 3GSDI MA TRIX ...

  • Gefen GEF-3GSDI-16416 - page 15

    12 Displaying the Routing Status From the main screen, press the Select button. When the arrow cursor is next to OUTPUT , pressing the ◄ or ► buttons on the front panel will show the current routing state of each input and output. The example below shows that Input 1 is routed to Output 1. Pressing the ► button again will display the routing ...

  • Gefen GEF-3GSDI-16416 - page 16

    13 IR REMOTE DESCRIPTION RMT -16416IR Remote Control Unit 1 Activity Indicator This LED will be activated momentarily each time a button is pressed. 2 Display and Source Selection Buttons (1 - 16) These buttons are used to select which source is routed to a monitor . Routing sources using the Remote Control unit Issuing a routing command is a two s ...

  • Gefen GEF-3GSDI-16416 - page 17

    14 Installing the RMT -16416IR Battery 1. Remove the battery cover on the back of the IR Remote Control unit. 2. Insert the included battery into the open battery slot. The positive (+) side of the battery should be facing up. 3. Replace the battery cover . The Remote Control unit ships with two batteries. One battery is required for operation and ...

  • Gefen GEF-3GSDI-16416 - page 18

    15 IR REMOTE CONFIGURA TION How to Resolve IR Code Con fl icts In the event that IR commands from other remote controls interfere with the supplied IR Remote Control unit, changing the IR channel on the IR Remote Control unit will fi x the problem. The IR Remote Control unit has a bank of DIP switches used for setting the IR channel. The DIP swit ...

  • Gefen GEF-3GSDI-16416 - page 19

    16 What features are available via the RS-232 serial communications port? The 16x16 3GSDI Matrix can accept commands through the RS-232 serial communications port located on the rear panel. The current RS-232 control features are: • Switching/routing of inputs to outputs without the RMT -16416IR remote control. How do I use these features? These ...

  • Gefen GEF-3GSDI-16416 - page 20

    17 RS-232 SERIAL CONTROL RS-232 Features RS-232 remote functions are used to control this product’s features. Features include input / output routing and reference signal functions . These features are available only through the use of the serial port. Functions Syntax The syntax for each function is always the same: #Function name → Space ( _ ...

  • Gefen GEF-3GSDI-16416 - page 21

    18 RS-232 SERIAL CONTROL #PRREFT ABLE Function The #PRREFT ABLE function displays the Reference In data table (timings) which are recognized by the 16x16 3GSDI Matrix. Syntax: #PRREFTABLE Parameters: None IP Con fi guration Functions Function Description #ISP ADD Sets the IP Address #SNETMASK Sets the Net Mask #SGA TEWA Y Sets the Gateway #SPORT S ...

  • Gefen GEF-3GSDI-16416 - page 22

    19 RS-232 SERIAL CONTROL #SNETMASK Function The #SNETMASK function speci fi es a new net mask. Syntax: #SNETMASK param1 param2 param3 param4 Parameters: param1 Net mask [0 - 255] param2 Net mask [0 - 255] param3 Net mask [0 - 255] param4 Net mask [0 - 255] Notes: A reboot is required after using this function. #SGA TEW A Y Function Speci fi es th ...

  • Gefen GEF-3GSDI-16416 - page 23

    20 RS-232 SERIAL CONTROL #SPORT Function Speci fi es a new port for a Web server . Syntax: #SPORT param1 Parameters: param1 Port [0 - 255] Notes: A reboot is required after using this function. #PRWEBADD Function Prints the current IP con fi guration on the screen. Syntax: #PRWEBADD Parameters: None ...

  • Gefen GEF-3GSDI-16416 - page 24

    21 RS-232 SERIAL CONTROL General Functions Function Description #ACTIVEBOLO Enables the boot loader #F ADEF AUL T Sets IP Con fi gurations to default settings #RMTIRADD Set the remote IR channel #RSTIP Sets IP con fi guration to default #ACTIVEBOLO Function The #ACTIVEBOLO function enables the boot loader . See the boot loader instructions on pag ...

  • Gefen GEF-3GSDI-16416 - page 25

    22 RS-232 SERIAL CONTROL #RMTIRADD Function The #RMTIRADD function set the remote IR channel. Syntax: #RMTIRADD param1 Parameters: param1 IR channel [0 - 3] #RSTIP Function Sets IP con fi guration to default (192.168.0.70) Syntax: #RSTIP Parameters: None Notes: This command requires the unit to be rebooted in order to take effect. ...

  • Gefen GEF-3GSDI-16416 - page 26

    23 Commands Command Description M Returns the current routing status of matrix R Routing command S Routes a single input to all outputs M Command The M command displays the current routing status of the matrix. Syntax: m Parameters: None R Command The R command allows speci fi c routing of inputs and outputs. Syntax: r param1 param2 Parameters: pa ...

  • Gefen GEF-3GSDI-16416 - page 27

    24 RS-232 SERIAL COMMANDS S Command The S command routes a single input to all 16 3GSDI outputs. Syntax: s param1 Parameters: param1 Input [1 - 16] Notes : Setting param1 to a value of 0 will place the matrix in one-to-one mode . This means that Input 1 will be routed to Output 1, Input 2 will be routed to Output 2, and so on. ...

  • Gefen GEF-3GSDI-16416 - page 28

    25 IP CONTROL The GefenPRO 16x16 3GSDI Matrix supports IP-based control using an integrated Web interface. T o access this feature, an IP address, subnet, gateway , and port number need to be set on the 16x16 3GSDI Matrix ( Default IP: 192.168.0.70 Subnet: 255.255.255.0 Gateway: 192.168.0.1 Port: 80 ). Consult the network administrator to obtain th ...

  • Gefen GEF-3GSDI-16416 - page 29

    26 IP CONTROL Masking The Masking page is used to hide an output from displaying any video. From this page, all outputs can be set to “Active” or “Mask”. When an output is set to “Active”, it will function normally . When an output is set to “Mask”, it will not output any video. T o set the “Active” or “Mask” mode, follow th ...

  • Gefen GEF-3GSDI-16416 - page 30

    27 IP CONTROL IP Con fi guration The IP Con fi guration page is used to set the IP settings that will be used to access the Web interface. The following items can be con fi gured from this menu. • IP Address (Default: 192.168.0.70) • Subnet (Default: 255.255.255.0) • Gateway (192.168.0.1) • Port (Default: 80) • • T o change these set ...

  • Gefen GEF-3GSDI-16416 - page 31

    28 IP CONTROL Backup / Restore The Backup/Restore page is used to backup and restore complete setup con fi gurations. Note: This feature will be implemented in a future release. ...

  • Gefen GEF-3GSDI-16416 - page 32

    29 FIRMW ARE UPDA TE Firmware Update Procedure T o Begin the update procedure the unit’s Boot Loader must be activated. T o activate the Boot Loader please follow the procedure below: If the unit is already powered on, the following RS-232 command can be used to activate the Boot Loader: 1. Connect RS-232 cable to PC and activate a terminal progr ...

  • Gefen GEF-3GSDI-16416 - page 33

    30 FIRMW ARE UPDA TE Follow the on-screen instructions to complete the fi rmware update process: 1. Press [1] on the computer keyboard to begin downloading program to the temporary memory . 2. A message will appear in Hyperterminal: W aiting for the fi le to be sent ... (press ‘a’ to abort) 3. In Hyperterminal, click T ransfer > Send File. ...

  • Gefen GEF-3GSDI-16416 - page 34

    31 W ARNING MESSAGES System Failure In the case of a critical malfunction, the following warning message will be displayed on the Main Display: If the 16x16 3GSDI Matrix is connected to a PC using a terminal program, the following message will appear on the display: System failure !!! Power-down the Matrix immediately and contact Gefen T echnical S ...

  • Gefen GEF-3GSDI-16416 - page 35

    32 RACK MOUNT SAFETY INFORMA TION a. Maximum recommended ambient temperature: 45 ˚ C b. Increase the air fl ow to maintain the temperature inside the rack. c. Install the product evenly to avoid mechanical overload. d. Connect an earthing wire between the an earthing stud and the grounding pin on the chassis. ...

  • Gefen GEF-3GSDI-16416 - page 36

    33 Input / Output • SDI (SMPTE 259MI up to 360 Mbps) • HD-SDI (SMPTE 292M up to 1.485 Gbps) • 3G-SDI (SMPTE 424M/425M up to 3.0 Gbps) Supported Formats......................................................All SD, HD, and 3G formats Maximum Resolution...........................................................1080p, 1920x1200, 2K Input / Output ...

  • Gefen GEF-3GSDI-16416 - page 37

    34 W ARRANTY Gefen warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen is noti fi ed within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that the equipment has not been subjected to mechanica ...

  • Gefen GEF-3GSDI-16416 - page 38

    35 LICENSING lwIP is licenced under the BSD licence: Copyright (c) 2001-2004 Swedish Institute of Computer Science. All rights reserved. Redistribution and use in source and binary forms, with or without modi fi cation, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright n ...

  • Gefen GEF-3GSDI-16416 - page 39

    Rev A3 Pb 20600 Nordhoff St., Chatsworth CA 91311 1-800-545-6900 818-772-9100 fax: 818-772-9120 www .gefenpro.com support@gefenpro.com ...

Manufacturer Gefen Category Switch

Documents that we receive from a manufacturer of a Gefen GEF-3GSDI-16416 can be divided into several groups. They are, among others:
- Gefen technical drawings
- GEF-3GSDI-16416 manuals
- Gefen product data sheets
- information booklets
- or energy labels Gefen GEF-3GSDI-16416
All of them are important, but the most important information from the point of view of use of the device are in the user manual Gefen GEF-3GSDI-16416.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Gefen GEF-3GSDI-16416, service manual, brief instructions and user manuals Gefen GEF-3GSDI-16416. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Gefen GEF-3GSDI-16416.

Similar manuals

A complete manual for the device Gefen GEF-3GSDI-16416, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Gefen GEF-3GSDI-16416 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Gefen GEF-3GSDI-16416.

A complete Gefen manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Gefen GEF-3GSDI-16416 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Gefen GEF-3GSDI-16416, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Gefen GEF-3GSDI-16416, that we can find in the current document
3. Tips how to use the basic functions of the device Gefen GEF-3GSDI-16416 - which should help us in our first steps of using Gefen GEF-3GSDI-16416
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Gefen GEF-3GSDI-16416
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Gefen GEF-3GSDI-16416 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Gefen GEF-3GSDI-16416?

Use the form below

If you did not solve your problem by using a manual Gefen GEF-3GSDI-16416, ask a question using the form below. If a user had a similar problem with Gefen GEF-3GSDI-16416 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)