Manual Friedrich P09A

24 pages 4.73 mb
Download

Go to site of 24

Summary
  • Friedrich P09A - page 1

    Ser vice Manual Portable Air Conditioner PORT -ServMan (04-09) Model: P09A P09B P012A P012B ...

  • Friedrich P09A - page 2

    FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .friedrich.com Printed in the U.S.A. TECHNICAL SUPPORT CONT ACT INFORMA TION ...

  • Friedrich P09A - page 3

    T able Of Contents Important Safety Information ....................................................................................................................2-4 Introduction ..................................................................................................................................................4 Unit Introduction ... ...

  • Friedrich P09A - page 4

    IMPORT ANT SAFETY INFORMA TION The information contained in this manual is intended for use by a qualied service technician who is familiar with the safety procedures required for installation and repair , and who is equipped with the proper tools and test instruments required to service this product. Installation or repairs made by unqualied ...

  • Friedrich P09A - page 5

    Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, • and sleeve on the room side of the air conditioning unit while cleaning. Electrical component malfunction caused by water could result in electric shock or other electrically • unsafe conditions when the power is restored and the u ...

  • Friedrich P09A - page 6

    PROPERTY DAMAGE HAZARDS FIRE DAMAGE HAZARDS: Read the Installation/Operation Manual for this air conditioning unit prior to operating. • Use air conditioner on a single dedicated circuit within the specied amperage rating. • Connect to a properly grounded outlet only . • Do not remove ground prong of plug. • Do not cut or mod ...

  • Friedrich P09A - page 7

    UNIT INT RODUCTION 5 1. Control panel 2. Air outlet 3. Signal receptor 4. Hand le 5. Caster 6. Air outlet hose 7. Air lter 8. Air intake hose 9. 1/2" water outlet drain 10. Power supply cord ...

  • Friedrich P09A - page 8

    6 Portable 2nd and 3rd DIGIT - Approximate BTU/HR (Cooling) Heating BTU/Hr capacity listed in the Specication/Performance Data Section Design Series Serial Number Decade Manufactured L=0 C=3 F=6 J=9 A=1 D=4 G=7 B=2 E=5 H=8 Y ear Manufactured A=1 D=4 G=7 K=0 B=2 E=5 H=8 C=3 F=6 J=9 Month Manufactured A=Jan D=Apr G=Jul K=Oct B=Feb E=May H=Aug L=No ...

  • Friedrich P09A - page 9

    TECHNICAL SPECIFICA TIONS P09A AND P12A 7 Model Co olin g Capac ity BTU/h Vo ltag e / Hz Amps Watt s Dimensions (W ” x H ” x D”) Dehumidica tion (Pints/Hour) Ind oor A ir Circulation (CFM ) Refri gerant Ch ar ge) (R- 22) Locked Rotor Amps Net Weigh t (lbs.) Circuit Rating Plu g Face (NEMA #) P09A 8900 1 15/60 8 923 19.5” x 33.6” x 15.5 ...

  • Friedrich P09A - page 10

    PRECA UTIONS FOR USE 8 Make sure the unit is installed in an accessible location. • Do not locate the unit in direct sunlight so as to avoid discoloration of the plastic. • Keep the unit 1 meter away from television sets or radios to avoid the risk of electromagnetic interference. • Ensure that the discharge air outlet is free from o ...

  • Friedrich P09A - page 11

    CONTR OL P ANEL OPERA TION 9 Dehu midif ying an d cooling operation The o perating rang e for c ooling op eration is 60 °F - 9 0°F , and the ope rating range for dehumidif ying is 6 8°F - 88° F . Power sour ce • The AC socket must be rm and re liable. • D on ’t connect the por tabl e air conditi oner to a multiple socket out le t whic ...

  • Friedrich P09A - page 12

    10 REMO TE CONTROL Used for adjusting the timer and • temperature The default display on control • panel is room temperature. When the " • " or the " " button is pressed in cool mode, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. T imer setting is a ...

  • Friedrich P09A - page 13

    4 Window adapter kit Window Panel Instructions for assembling the window adapter kit 1. Insert tube adapters through the back of the window panel. 2. Secure each tube adapter with four screws through the front of the window panel. 3. Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensi ...

  • Friedrich P09A - page 14

    5 Window installation Maintain a clear distance (from walls, furniture, etc.) of at least 10 inches ar ound the unit to allow pr oper air cir culation and prevent damage to the unit. Important: Do not over -stretch the exhaust tube or make any unnecessary bends in it. Installing the window adapter kit Note: The window adapter kit must be installed ...

  • Friedrich P09A - page 15

    Y our ZoneA ire ® P o r t a b l e A i r C o n d i t i o n e r i s d e s i g n e d t o ev ap orate the c ondensation removed from the interio r spac e through the exhaust hose. Under cer tai n conditi ons it is possib le that the unit will not evaporate 100% of the remov ed mo istu re. The unit i s de signed with a built-in reser voir to ac cumulat ...

  • Friedrich P09A - page 16

    MAINTENANCE / SER VICE Unplug and/or disconnect all electrical power to the unit before performing inspections, maintenances or service. Failure to do so could result in electric shock, serious injury or death. W ARNING RISK OF ELECTRIC SHOCK P reparation for storage 1 . T urn of f the air c onditioner , disco nnect the power . 2. Per form proper m ...

  • Friedrich P09A - page 17

    TROUBLESHOO TING 15 ...

  • Friedrich P09A - page 18

    16 TROUBLESHOO TING The compressor bolts are loose or copper tubes are contacting other metal parts T ighten bolts Adjust copper tubes Unblock (below72 F) ...

  • Friedrich P09A - page 19

    17 REFRIGERA T OR SY STEM DIAGRAM SCHEMA TIC WIRING DIAGRAM ...

  • Friedrich P09A - page 20

    18 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com PORTABLE AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR AN Y PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no ...

  • Friedrich P09A - page 21

    ...

  • Friedrich P09A - page 22

    20 ...

  • Friedrich P09A - page 23

    FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .friedrich.com Printed in the U.S.A. TECHNICAL SUPPORT CONT ACT INFORMA TION ...

  • Friedrich P09A - page 24

    FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .friedrich.com Printed in the U.S.A. PORT -ServMan (04-09) ...

Manufacturer Friedrich Category Air Conditioner

Documents that we receive from a manufacturer of a Friedrich P09A can be divided into several groups. They are, among others:
- Friedrich technical drawings
- P09A manuals
- Friedrich product data sheets
- information booklets
- or energy labels Friedrich P09A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Friedrich P09A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Friedrich P09A, service manual, brief instructions and user manuals Friedrich P09A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Friedrich P09A.

A complete manual for the device Friedrich P09A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Friedrich P09A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Friedrich P09A.

A complete Friedrich manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Friedrich P09A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Friedrich P09A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Friedrich P09A, that we can find in the current document
3. Tips how to use the basic functions of the device Friedrich P09A - which should help us in our first steps of using Friedrich P09A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Friedrich P09A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Friedrich P09A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Friedrich P09A?

Use the form below

If you did not solve your problem by using a manual Friedrich P09A, ask a question using the form below. If a user had a similar problem with Friedrich P09A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)