    Integr at ed S ensor Suite Installation Manual F or V antage Pro2 & V antage P ro2 Plus W eather Stations ™™ Davis Instruments, 3465 Diablo A venue, Hayward, CA 94545 • 510-732-9229 • www.da visnet.com 07395.249 Manual ISS Installation_RevE_Final_Print.pdf 1 4/7/2008 1:44:47 PM ...

  • DAVIS 6322C - page 2

    Integrated Sensor Suite Installation Manual Rev . E, April 7, 2008 Document Part Number: 07395.249 For V antage Pro2 Weather S tations # 6322, 6322C, 6323, 6327, 6327C, 6328 For V antage Pro2 systems 6152C, 6162C, 6152, 6162, 6153, and 6163 V antage Pro ® an d V antage Pro2 ™ are trademarks of Davis Instrument s Corp., Hayward, CA. © Davis Inst ...

  • DAVIS 6322C - page 3

    1 Introduction The Integrated Sensor Suite (ISS) collects out side weather data and sends the data to a V antage Pro2 console or W eather Envoy . Wire less and cabled versions of the ISS are available, as well as Standa rd and Plus versions. The W ireless ISS is solar powered and sends data to the con s ole via a low-power radio. The Cabled ISS sen ...

  • DAVIS 6322C - page 4

    Preparing the ISS for Installation 2 Note: If the ISS is a Pl us model and cont ains UV and so lar sensors, do not touch t he small white dif fusers on top of t he sensors. Oil from skin reduces their sensitivit y . If you are con c erned t hat you have touched the diff users at any time during the installation, clean t he UV diffuser using eth y l ...

  • DAVIS 6322C - page 5

    Preparing the ISS for Installation 3 The steps to prepare the ISS for insta llation are: • Assemble t he anemometer . • Check the factory-installed sens or cable connections to the SIM. • Connect the anemometer sensor cable to the S IM. • Apply power to the ISS and test commun ication with the console. • Change the T ransmitter ID for wir ...

  • DAVIS 6322C - page 6

    Check SIM Sensor Connections 4 4. Slide the tooth-lock washer and hex nut onto the machine screw . Tighten the hex nut while holding the screw with a Phillips head screwdriver to prevent it from turning. 5. Press the sensor cable firmly and complete ly into the zig -zagging channel in the base, starting from the arm and progressin g downward to the ...

  • DAVIS 6322C - page 7

    Check SIM Sensor Connections 5 Open the SIM Box 1. Locate the white box with the solar panel containing the SIM on the front of the ISS unit. The cabled model does not have a solar panel. 2. Locate the whit e tab at the bottom ce nter of the SIM box cover . 3. Lift the tab away from the box while slid- ing the cover up. Look on the side of the SIM ...

  • DAVIS 6322C - page 8

    Check SIM Sensor Connections 6 Connect the Anemometer Cable to the SIM 1. Unwind the coi l of cable enou gh to work with the anemometer . Note: Do not unwind the entire coil of anemometer cabl e at this time. 2. Pull the foam insert out of cable access port in between the ca bles and set the foam insert aside. 3. Insert the anemomet er cable end in ...

  • DAVIS 6322C - page 9

    7 Cabled ISS Assembly The Cabled ISS system co ntains a cable for connecting the ISS to a V antage Pro2 cabled console. Once the anemometer has been inst alled and the sensors ha ve been checked, a cabled connection between the ISS and the console can be es tablished. Follo w the steps below for powering the ISS an d connecting to the console. Appl ...

  • DAVIS 6322C - page 10

    Troubleshooting Cabled ISS Communication 8 Approximately one minute after power-up the outside relative humidity reading should be displaye d on the console. 5. If the ISS contains a UV sensor and/or so lar sensor , press 2ND and then p ress RAIN YR for current ultraviolet readings or press 2ND then press RAIN DA Y for solar radiation readings. The ...

  • DAVIS 6322C - page 11

    9 Wireless ISS Assembly The ISS has a wireless conne ction to a V antage Pro2 wi reless console. Once the anemometer has been installed and th e sens ors have been checked, the ISS must be powered and a wireless communication channel must be established between the ISS and the console. Follow the steps below for power ing the ISS and establ ishing ...

  • DAVIS 6322C - page 12

    Verifying Data from the ISS Sensors 10 V erifying Data from the ISS Sensors Use these steps to v erify reception of ISS data at the wireless V antage Pro2 console and to test the operation of the ISS sensors. 1. Press and hold DONE until the Current W eathe r screen displays, if the console is in Setup Mode. Sensor readings from the ISS should disp ...

  • DAVIS 6322C - page 13

    Troubleshooting Wireless ISS Reception 11 Note: If the LED is flashing rapid ly , call T echnical Support. See “Cont acting Davis Instruments” on page 2 7 for more i nformation. See “SIM Board Display and Contents” on page 30 for information on locating the components and points of interest on the SIM board. 5. If the LED remains dark, ther ...

  • DAVIS 6322C - page 14

    Troubleshooting Wireless ISS Reception 12 T ransmitter ID DIP Switches in T op-right Corner of SIM T o change to another ID, use a ballpoint pen or paper clip to toggle DIP switches #1, 2, and 3. The settings for T ransmitter IDs 1 - 8 are shown in the table below . Set the V antage Pro2 console to the same ID as the transmitters, as described in t ...

  • DAVIS 6322C - page 15

    13 Prep aring the ISS for Inst allation Once all the sensors have been co nnected and communication betw een the IS S and the console has been successfu lly established, c ontinue to prepare the ISS unit for installation. The steps for preparing the ISS for installation are as follows. •C l o s e t h e S I M B o x • Prepare the Solar Panel • ...

  • DAVIS 6322C - page 16

    Prepare the Rain Collector 14 4. While watching the daily rain display , tip the bucket until it drops to the op posite side, then wait two seconds to see if the display registers a rain readin g. Each tip indicates 0.01" of rain and may take up to a minute to register at the cons ole. If the bucket is tipped too quickly , the number on th e c ...

  • DAVIS 6322C - page 17

    Locating the ISS and Anemometer 15 5. Slide the magnet, exposed end of magnet first, into the open slot of the metric adapter . 6. Insert the metric adapter and ma gnet between the arms of the bucket, with the solid side of the metric adapte r facing up. Open plastic arms to insert metric measurement adapter , with adapter in “V” position Note: ...

  • DAVIS 6322C - page 18

    Locating the ISS and Anemometer 16 For agricultural applications (Important for evapotranspi ration (ET) calculations) : • Install the ISS and anemometer as a si ngle unit with the radiation shield 5' (1.5 m) above the ground and in the middl e of the farm b etween similar crop types (i.e. two orchards, tw o vineyards or two row crops), if p ...

  • DAVIS 6322C - page 19

    Locating the ISS and Anemometer 17 Optional: Anemometer Cable Length Considerations • All V antage Pro2 stations include a 40' (12 m) cable to go between the ISS and the anemometer . This can be extended up to 540' (165 m) using optional extension cables purchased from Davis Instruments. • If most of the anem ometer cable length is un ...

  • DAVIS 6322C - page 20

    Locating the ISS and Anemometer 18 • If possible, align the pivot joints of both th e ISS a nd the console antenna s so that they are facing each other fo r maximum signal strength. • The ISS and console antennas do not rotate in a complete circle. A void forcing the antennas when rotatin g it. • T urn the gain on to improve reception of a we ...

  • DAVIS 6322C - page 21

    19 Inst alling the ISS The anemometer an d the main part of the ISS ca n be installed either together as a single unit on a pole, or apart from each other . The main part of the ISS includ es the rain collector , the temperature and humidi ty sensors, the radiation shield, and the SIM housing. Use the U-bolts to install the ISS a nd anemometer toge ...

  • DAVIS 6322C - page 22

    Installing the ISS on a Flat Surface 20 Inst allation Instructions There are several ways to mount and install the ISS unit. The foll owing are installation types that Davis Instruments recommends. Individ ual ISS lo cations and installations may vary . • Installing the ISS on a flat surface • Installing the Anemometer on a post or flat surface ...

  • DAVIS 6322C - page 23

    Installing the ISS on a Pole 21 Option 2: Installing the A nemometer on a Post or Flat Surface 1. W ith a 3/16" (5 mm) drill bit, drill two hol es approximately 2-1/8" (54 mm) apa rt. Use a carpenter’ s level to ensure the hole s will be level. 2. Insert the 1/4" x 3" lag screws throu gh the flat washers a nd the holes in the ...

  • DAVIS 6322C - page 24

    Installing the ISS on a Pole 22 Guidelines for Inst alling the ISS on a Pole • When mounting both sides together , remember that whichever side of the ISS is mounted first, the U-bolt from the opposite side must also be placed around the pole before tightening the U-bolts. (If it is not, there is no way to slide it in later .) • In each side’ ...

  • DAVIS 6322C - page 25

    Finishing the Installation 23 3. T ighten the hex nuts using an adjustable wrench or 7/16" wrench. 4. Re-attach the rain collector cone. Set the cone back on the base so its latche s slide downward into the latch openings on the base. Rotate th e cone clockwise. 5. Place the debris screen (shown in the illu stration on page 1) inside the cone, ...

  • DAVIS 6322C - page 26

    Additional Mounting Options 24 Extending the Console Cable (Cabled ISS Only) A Cabled ISS can be extended up to 1000' (300 m) away from the console by using Davis Instruments extension cables (#7876). Relocating the Anemometer Using Extension Cables: Note: Not all cables are compatible with your V antage Pro2 system. T o be sure they will work ...

  • DAVIS 6322C - page 27

    25 Maintenance and T roubleshooting Maint aining UV and Solar Radiation Sensors If the ISS is a Plus model and contains UV a nd solar radiation sensors, do not touch the small white diffusers on top of the sensors. Oi l from skin reduces their sensitivity . If you are concerned that you have touched the diff users at any time, clean the UV dif fuse ...

  • DAVIS 6322C - page 28

    Troubleshooting 26 Note: For some models of the ISS, th e order in which the five radiation shield plates are assembled may be slightly dif ferent than the o rder shown in the figure on page 25. For this reason, ensure that yo u always reassemble the plate s in the same order in which they were disassembled. 4. Reassemble the plates in th e same or ...

  • DAVIS 6322C - page 29

    Troubleshooting 27 “The wind cups are spinning but my console displays 0 mph.” The signal from the wind cups may not be ma king it back to the display . Remove the cups from the anemomete r (loosen the set screw). Put the cups back onto the shaft and make sure to slide them up the sh aft as far as possible. Check your cables for visible nicks a ...

  • DAVIS 6322C - page 30

    28 Appendices Appendix A: Re-orienting the Wind V ane The V antage Pro2 station is configured to register wind direction correctly if the anemometer points to true north. If the anemometer shaft cannot be mounted to point to true north, use the following instructions to correct the wind vane orientation. • Do not rely on a compa ss unless it is p ...

  • DAVIS 6322C - page 31

    Appendix B: Specifications 29 1 1. T est the anemometer by pointing the wi nd vane in any directio n and making sure the console displa ys the correct wi nd direction. Remove and re-adjust the vane if it does not. Allo w the wind direction display approximately 5 seconds to stabilize a fter turning the shaft. Appendix B: S pecifications Complete sp ...

  • DAVIS 6322C - page 32

    SIM Board Display and Contents 30 SIM Board Displ ay and Content s SENSOR SENSOR INTERF ACE INTERF ACE MODULE MODULE UV UV SUN SUN RAIN RAIN WIND WIND TEMP TEMP HUM HUM + - 1 2 3 4 5 6 7 8 9 10 11 12 1 Solar Panel Ta b 2 AC Adapter Socke t 3 4 Battery Socket Cabled Connection 5 T ransmitter ID DIP Switch 6 T est DIP Switch 7 T est LED 8 9 10 11 12 ...

Manufacturer DAVIS Category Home Security System

Documents that we receive from a manufacturer of a DAVIS 6322C can be divided into several groups. They are, among others:
- DAVIS technical drawings
- 6322C manuals
- DAVIS product data sheets
- information booklets
- or energy labels DAVIS 6322C
All of them are important, but the most important information from the point of view of use of the device are in the user manual DAVIS 6322C.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals DAVIS 6322C, service manual, brief instructions and user manuals DAVIS 6322C. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product DAVIS 6322C.

Similar manuals

A complete manual for the device DAVIS 6322C, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use DAVIS 6322C by users. Manuals are usually written by a technical writer, but in a language understandable to all users of DAVIS 6322C.

A complete DAVIS manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual DAVIS 6322C - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the DAVIS 6322C, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the DAVIS 6322C, that we can find in the current document
3. Tips how to use the basic functions of the device DAVIS 6322C - which should help us in our first steps of using DAVIS 6322C
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with DAVIS 6322C
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of DAVIS 6322C in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning DAVIS 6322C?

Use the form below

If you did not solve your problem by using a manual DAVIS 6322C, ask a question using the form below. If a user had a similar problem with DAVIS 6322C it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)