  • Monarch ACT-1B - page 1

    ACT-1B, ACT-1B-10, ACT-1B-60 Panel Tachometers MONARCH INSTRUMENT Instruction Manual 15 Columbia Drive Amherst, NH 03031-2334 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: techsup@monarchinstrument.com Website: www.monarchinstrument.com Printed in the U.S.A. © Monarch Instrument 2001 all rights reserved 1071-4842-114 ...

  • Monarch ACT-1B - page 2

    Safeguards and Precautions 1. Read and follow all instructions in this manual carefully, and retain this manual for future reference. 2 . Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated. 3. Be sure the power supplied to this instrumen ...

  • Monarch ACT-1B - page 3

    Specifications ................................................................. 1 Overview ........................................................................ 2 Installation and Power .................................................... 2 Sensor Connections ...................................................... 4 Output Options .............. ...

  • Monarch ACT-1B - page 4

    1 SPECIFICATIONS Range: 5 to 99,999 RPM Accuracy: ±1 RPM or 0.005% of reading Resolution: 1 RPM Display: 5 digit, 0.56” (14 mm) high red LED Display Update: Twice per second above 120 RPM Dimensions: 1/8 DIN by 4.5” (114 mm) deep Power Supply: Standard: 115 Vac or 230 Vac ± 10%, 50/60 Hz (Specified when ordering) Optional: 12 Vdc to 15 Vdc, 1 ...

  • Monarch ACT-1B - page 5

    2 OVERVIEW ACT-1B Digital Tachometers display rotational speed directly in RPM on a 5 digit red LED display using a speed sensor providing a single pulse per revolution (Model ACT-1B), 10 pulses per revolution (Model ACT-1B-10) or 60 pulses per revolution (Model ACT-1B-60). Power may be either 115 Vac or 230 Vac (50/60 Hz), or optionally, 12 Vdc to ...

  • Monarch ACT-1B - page 6

    3 Installation Remove the mounting clips, if fitted, and install the unit into the panel from the front. From the rear of the unit, install the mounting clips on each side and tighten the mounting screws against the rear of the panel. WARNING: Do not over tighten the mounting screws. Power Power to the unit is connected to the terminals under the s ...

  • Monarch ACT-1B - page 7

    4 If the unit is dc powered , connect the dc supply Positive to the terminal marked L+ and the dc supply Negative or Common to the terminal marked N- . NOTE: On dc powered units, no connection is required to the terminal marked GND . SENSOR CONNECTIONS A speed sensor (not included) is connected to the terminals under the section labeled INPUT on th ...

  • Monarch ACT-1B - page 8

    5 Refer to Figure 3 for connection of Monarch standard sensors. The connections are typical for these types of sensors. Figure 3 Sensor Connections Shield to COM Shield to COM 6 OUTPUT OPTIONS The ACT-1B may be equipped with either a Current Output (IO) or an Analog Output (AO), and/or a TTL Pulse Output (PO). NOTE: Full scale RPM settings must hav ...

Manufacturer Monarch Category Automobile Parts

Documents that we receive from a manufacturer of a Monarch ACT-1B can be divided into several groups. They are, among others:
- Monarch technical drawings
- ACT-1B manuals
- Monarch product data sheets
- information booklets
- or energy labels Monarch ACT-1B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Monarch ACT-1B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Monarch ACT-1B, service manual, brief instructions and user manuals Monarch ACT-1B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Monarch ACT-1B.

Similar manuals

A complete manual for the device Monarch ACT-1B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Monarch ACT-1B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Monarch ACT-1B.

A complete Monarch manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Monarch ACT-1B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Monarch ACT-1B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Monarch ACT-1B, that we can find in the current document
3. Tips how to use the basic functions of the device Monarch ACT-1B - which should help us in our first steps of using Monarch ACT-1B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Monarch ACT-1B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Monarch ACT-1B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Monarch ACT-1B?

Use the form below

If you did not solve your problem by using a manual Monarch ACT-1B, ask a question using the form below. If a user had a similar problem with Monarch ACT-1B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)