Manual Newcon Optik LAM 10M IR

24 pages 0.33 mb
Download

Go to site of 24

Summary
  • Newcon Optik LAM 10M IR - page 1

    Operation Manual LAM 10M IR LASER AIMING MODULE / TARGET POINTER 105 Sparks Ave., Toronto, ON, M2H 2S5, Canada ...

  • Newcon Optik LAM 10M IR - page 2

    ...

  • Newcon Optik LAM 10M IR - page 3

    IMPORTANT INFORMATION Read prior to activation You have ju st purchased a sophisticated el ectronic de vice. To operate it properly, please read this manual carefully. LAM belongs t o Class I laser products i n accordance wit h IEC 60825-1. Her e are some common precautions that must be observed. • ALWAYS turn the de vice off when it is not in us ...

  • Newcon Optik LAM 10M IR - page 4

    1 CONTENTS 1. Brief description ................................................. 2 2. Device design ..................................................... 3 3. DELIVERY S ET ................................................ 8 3.1. Standar d delivery set ...................................... 8 3.2. Optional parts..................................... ...

  • Newcon Optik LAM 10M IR - page 5

    2 Carefully read all the instructions prior to use. Failure to obey the instructions will void the warranty ! INVISIBLE LASER RADIAT ION CLASS I LASER PRODUCT 830–860 nm 0,1mW. 1. Brief description LAM 10M IR l aser aimer (her einafter referred as LAM) is designed for precise aiming at night time. LAM forms an IR laser radiation spot on the targe ...

  • Newcon Optik LAM 10M IR - page 6

    3 2. Device design 17 16 14 8 7 6 5 4 3 2 1 ...

  • Newcon Optik LAM 10M IR - page 7

    4 Fig. 1. LAM 10M IR 1 – clamp 2 – bracket 3 – stopper 4 – remote connector 5 – body 6 – emitter 7 – emitter cap 8 – emitter protective cap 9 – windage adjustm ent 10 – fastener 11 – ‘laser on’ warnin g indicator 12 – elevation adjustment 13 – fixati on screw cap 14 – fixati on screw 15 – battery compartment cap 16 ...

  • Newcon Optik LAM 10M IR - page 8

    5 LAM consists of an emitter (6,7, Fig.1), a battery compartment (15,16, Fig.1), wind age (9, Fig.1) and elevatio n (12, Fig.1) a djustment mechanism s, an operating m odes switch (17, Fig.1), a remote switch (Fig.2), a clamp (1, Fig.1). A battery is to be inserted into the battery compartment (16, Fig.1). Battery compartment cap (15, Fig.1) is att ...

  • Newcon Optik LAM 10M IR - page 9

    6 LAM automatically turns off after 30 minutes of being switched in positions C and R. I n order to act ivate LAM aft er it has automatically turned off, return the switch (17, Fig.1) into OFF position and then switch it to the desired position again. The remote switch (Fig.2) can be attached to LAM by a connector (3, Fig.2) with a union nut. When ...

  • Newcon Optik LAM 10M IR - page 10

    7 1 — key; 2 — velcro tape; 3 — connector Fig. 2. Remote switch 1 2 3 ...

  • Newcon Optik LAM 10M IR - page 11

    8 3. DELIVERY SET 3.1. Standard delivery set LAM is supplied in the following assembly: Quantity, pcs LAM 10M IR 1 Remote switch 1 Velcro tape 2 O-Ring 1 Case 1 Manual 1 Battery CR123 1 3.2. Optional parts LAM can be supplied wit h a barrel mount. ...

  • Newcon Optik LAM 10M IR - page 12

    9 4. Specifications Laser wavelength 830…850 nm Beam divergence 0.5 mrad Spot size at 50 meters 25 mm Windage and elevation ad justment range ±20 mrad Windage and elevation adjustment step 0.5 mrad (50 mm @100m) Accuracy of adjustment after 1000 shots 0.1 mrad Accuracy of adjustment after 100 re- mountings on a rail 1 mrad Laser emitting p ower ...

  • Newcon Optik LAM 10M IR - page 13

    10 5. OPERATION INSTRUCTIONS 5.1. Installing the battery LAM is powe red by a sta ndard Lithi um CR123 3V battery . To install a battery: - unscrew the ba ttery compar tment cap (15, Fig. 1), - insert a battery observing the polarity as marked on the battery compartment, - check the condition of the O-ring on the body; replace it if worn or torn, - ...

  • Newcon Optik LAM 10M IR - page 14

    11 5.3. Connecting the remote c ontrol To connect the remote switch (Fig.2): - unscrew the ca p of the rem ote connect or (4, Fig. 1) and store it in a safe place, - plug in the rem ote connector c ontact (3, Fig. 2) observi ng the key visible on the cable side, - tighten the union nut, - attach the remote switch to the weapon pivot or grip with ve ...

  • Newcon Optik LAM 10M IR - page 15

    12 - remove protective cap (8, Fig. 1) from emitter tube output win dow; - activate LAM in mode C; - match the ce nter of radi ation spot wi th the aim ing mark by means of r otating ha ndwheels of adjustm ent mechanisms; - perform test firing with LAM under the same conditions as when checking th e weapon fire capability with an iron sight; - elim ...

  • Newcon Optik LAM 10M IR - page 16

    13 6. Maintenance, storage and transportation 6.1. General LAM is a sophisticated precise optical in strument equipped with electronics. Therefore, it should be handled with du e care. - Never disassem ble LAM. - Keep away from direct sunlig ht, im pacts, dust, moisture, and sharp changes of temperature. - Do not keep LAM at temperatures highe r th ...

  • Newcon Optik LAM 10M IR - page 17

    14 6.2. Storage To set LAM from com bat position into a stowed one: - turn LAM off (operati ng modes swi tch (17, Fig.1) shoul d be set to OFF position); - cover emitter tube output window with protective cap (8, Fig.1); - disconnect remote switch (Fig.2) from the weapon, l oosen screw caps (13, Fig.1), remove LAM wi th remote switch from Picatinny ...

  • Newcon Optik LAM 10M IR - page 18

    15 To apply new layer of lubricant: - Within two hours from cleaning apply an even 0.2-0.5 mm thick layer of lubricant on m etal surfaces with a brush. - Do not cover plastic parts. When preparing for a long-term storage LAM just recei ved from ma nufacturer or from workshop, ensure that actual set is the same as indicated in the Delivery Set secti ...

  • Newcon Optik LAM 10M IR - page 19

    16 - Cover aim er with protecti ve cap. - Disconnect the remote switch from the weapon. - Dismount L AM from Picatinny rail . - Pack LAM and remote switch into the case. When packed, LAMs ca n be transported by any covered means in accordance with storag e conditions as described in this manual. When in operation, LAM is to be tran sported in its c ...

  • Newcon Optik LAM 10M IR - page 20

    17 7. TROUBLESHOOTING Spot shape or size has chan ged Emitter objective lens is dirty. Flush emitter lens with fresh water and wipe it with soft cloth. No radiation when activating LAM with remote switch Turn the operating modes switch (17, Fig.1) to OFF position and then turn LAM ON again. If this doesn’t help, replace the remote switch. Radiati ...

  • Newcon Optik LAM 10M IR - page 21

    18 8. WARRANTY NEWCON OPTIK warrants this produc t against defects in material and workmanship for one year from the date of t he original dat e of consum er's purchase. S hould you r Newcon product pro ve defective du ring this pe riod, please bri ng the product securel y packaged in i ts original c ontainer or an equivalent, along with proof ...

  • Newcon Optik LAM 10M IR - page 22

    19 9. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OPTIK product, consult the enclo sed manual. If the problem remains unresol ved, contact our customer su pport departm ent at +1(416) 663-6963 or toll free at 1-877-368-66 66. Our operating hours are 9am -5pm, Monday - Friday, Easte rn Standard Tim e. At no time should ...

  • Newcon Optik LAM 10M IR - page 23

    20 10. QUALITY CERTIFICATE LAM10M IR serial n umber: _____________ ____________ _______________ ________ complies with all technical sp ecifications and has passe d the quality inspectio n. Date of production : ____________ _______________ ______ Quality Inspector : ___________________ _______________ Quality Assurance Seal ...

  • Newcon Optik LAM 10M IR - page 24

    NEWCON OPTIK ™ 2011 R1 – 2.11 ...

Manufacturer Newcon Optik Category Laser Pointer

Documents that we receive from a manufacturer of a Newcon Optik LAM 10M IR can be divided into several groups. They are, among others:
- Newcon Optik technical drawings
- LAM 10M IR manuals
- Newcon Optik product data sheets
- information booklets
- or energy labels Newcon Optik LAM 10M IR
All of them are important, but the most important information from the point of view of use of the device are in the user manual Newcon Optik LAM 10M IR.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Newcon Optik LAM 10M IR, service manual, brief instructions and user manuals Newcon Optik LAM 10M IR. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Newcon Optik LAM 10M IR.

A complete manual for the device Newcon Optik LAM 10M IR, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Newcon Optik LAM 10M IR by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Newcon Optik LAM 10M IR.

A complete Newcon Optik manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Newcon Optik LAM 10M IR - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Newcon Optik LAM 10M IR, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Newcon Optik LAM 10M IR, that we can find in the current document
3. Tips how to use the basic functions of the device Newcon Optik LAM 10M IR - which should help us in our first steps of using Newcon Optik LAM 10M IR
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Newcon Optik LAM 10M IR
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Newcon Optik LAM 10M IR in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Newcon Optik LAM 10M IR?

Use the form below

If you did not solve your problem by using a manual Newcon Optik LAM 10M IR, ask a question using the form below. If a user had a similar problem with Newcon Optik LAM 10M IR it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)