Manual Mitsubishi Electronics MXZ-4A80VA

12 pages 0.55 mb
Download

Go to site of 12

Summary
  • Mitsubishi Electronics MXZ-4A80VA - page 1

    Refer to the installation manual of each indoor unit for indoor unit installation. INST ALLA TION MANUAL FOR INST ALLER CONTENTS 1. THE FOLLOWING SHOULD AL W A YS BE OBSER VED FOR SAFETY ........................................................................................... 2 2. INST ALLA TION DIAGRAM & ACCESSORIES ......................... ...

  • Mitsubishi Electronics MXZ-4A80VA - page 2

    2 K H F I J E C D 2 . INST ALLA TION DIAGRAM & ACCESSORIES 1. THE FOLLOWING SHOULD AL W A YS BE OBSER VED FOR SAFETY • Be sure to read “THE FOLLOWING SHOULD ALW A YS BE OBSERVED FOR SAFETY” before install- ing the air conditioner . • Be sure to observe the cautions specified here as they include important items related to safety . • T ...

  • Mitsubishi Electronics MXZ-4A80VA - page 3

    3 Parts to be locally procured A Power supply cord 1 (3-core 2.5 mm 2 ) B Indoor/outdoor unit connecting wire 1 (4-core 1.0 mm 2 /1.5 mm 2 ) C Extension pipe According to “Selecting pipe size” 1 D Wall hole cover 1 E Piping tape 1 F Extension drain hose (or soft vinyl chloride hose of 1 15 mm in internal dia. or hard vinyl chloride pipe VP16) G ...

  • Mitsubishi Electronics MXZ-4A80VA - page 4

    4 4. OUTDOOR UNIT INST ALLA TION 4-1 INST ALLING THE UNIT • Be sure to fix the unit ’ s legs with bolts when installing it. • Be sure to install the unit firmly to ensure that it does not fall by an earthquake or a gust. • Refer to the figure in the right for concrete foundation. Note: The length of anchor bolts should be within 25 mm from ...

  • Mitsubishi Electronics MXZ-4A80VA - page 5

    5 Connect to the supply terminals and leave a contact separation of at least 3 mm at each pole to disconnect the source power pole. (When the power switch is shut of f, it must disconnect all poles.) <Front View> <Right Side View> 35 mm 15 mm Indoor/Outdoor unit connecting wire B Cable clamp Power supply cord A 4-4 INDOOR/OUTDOOR WIRE C ...

  • Mitsubishi Electronics MXZ-4A80VA - page 6

    6 Copper pipe Good No good Tilted Uneven Burred Burr Copper pipe Spare reamer Pipe cutter Flare nut Copper pipe 5-2 FLARING WORK • Main cause of gas leakage is defect in flaring work. Perform flaring work correctly in the following procedure. 1. Pipe cutting • Cut the copper pipe correctly with pipe cutter . 2. Burrs removal • Completely remo ...

  • Mitsubishi Electronics MXZ-4A80VA - page 7

    7 A Die Copper pipe Flare nut Die Copper pipe Smooth all around Even length all around Inside is shining without any scratches Y ork 4. Flaring work • Perform flaring work using flaring tool as shown in the right. A (mm) Outside diameter Flare tool for R410A Conventional flare tool clutch type Clutch type Wing nut type ø 6.35 mm 0 to 0.5 1.0 to ...

  • Mitsubishi Electronics MXZ-4A80VA - page 8

    8 W ARNING: When installing or moving the unit, do not mix anything other than specified refrigerant (R410A) into the refrigerating cycle. If air is mixed, it may cause the refrigerating cycle to get abnormally high temperature, causing a risk of burst. Tightening torque N · m kgf · cm Cap for service port 13.7 to 17.7 140 to 180 Cap for stop val ...

  • Mitsubishi Electronics MXZ-4A80VA - page 9

    9 A B C D 5-9 GAS CHARGE Perform gas charge to unit. 1 Connect gas cylinder to the service port of stop valve. 2 Perform air purge of the pipe (or hose) coming from refrigerant gas cylinder . 3 Replenish specified amount of the refrigerant, while operating the air conditioner for cooling. Note: In case of adding refrigerant, comply with the quantit ...

  • Mitsubishi Electronics MXZ-4A80VA - page 10

    ...

  • Mitsubishi Electronics MXZ-4A80VA - page 11

    ...

  • Mitsubishi Electronics MXZ-4A80VA - page 12

    HEAD OFFICE: T OKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN SG79Y674H01 ...

Manufacturer Mitsubishi Electronics Category Air Conditioner

Documents that we receive from a manufacturer of a Mitsubishi Electronics MXZ-4A80VA can be divided into several groups. They are, among others:
- Mitsubishi Electronics technical drawings
- MXZ-4A80VA manuals
- Mitsubishi Electronics product data sheets
- information booklets
- or energy labels Mitsubishi Electronics MXZ-4A80VA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Mitsubishi Electronics MXZ-4A80VA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Mitsubishi Electronics MXZ-4A80VA, service manual, brief instructions and user manuals Mitsubishi Electronics MXZ-4A80VA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Mitsubishi Electronics MXZ-4A80VA.

A complete manual for the device Mitsubishi Electronics MXZ-4A80VA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Mitsubishi Electronics MXZ-4A80VA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Mitsubishi Electronics MXZ-4A80VA.

A complete Mitsubishi Electronics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Mitsubishi Electronics MXZ-4A80VA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Mitsubishi Electronics MXZ-4A80VA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Mitsubishi Electronics MXZ-4A80VA, that we can find in the current document
3. Tips how to use the basic functions of the device Mitsubishi Electronics MXZ-4A80VA - which should help us in our first steps of using Mitsubishi Electronics MXZ-4A80VA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Mitsubishi Electronics MXZ-4A80VA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Mitsubishi Electronics MXZ-4A80VA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Mitsubishi Electronics MXZ-4A80VA?

Use the form below

If you did not solve your problem by using a manual Mitsubishi Electronics MXZ-4A80VA, ask a question using the form below. If a user had a similar problem with Mitsubishi Electronics MXZ-4A80VA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)