    Page 1 iS520, iS521 and iS550 User’s Manual Version: 1.3 ...

  • Paralan iS521 - page 2

    Page 2 LIMI TED WARRANTY Paralan Corporation (Pa ralan) warrants this product (Pr oduct) to be free of defects in mat erial and workmans hip for an initial period of two (2) years from date of deliver y to t he origin al purchaser (Purchas er) from Paral an. Repai r or Replacement. Paralan’s obligati on under this warrant y is limited to replacin ...

  • Paralan iS521 - page 3

    Page 3 NOTE: This equipment has been tested and found to com pl y w ithin the limits for a Class B digital device, pursuant to Part 15 of the F CC Rules. These limit s are designed to provide reasonable protection against harmful interference when the equip ment is operated in a commercial environment. This equipment generates, uses, and can radiat ...

  • Paralan iS521 - page 4

    Page 4 PARALAN CORPORATION 4655 Ruffner Street San Diego, CA 92111 Toll Free: (866) 447-6293 Corporate: (858) 560-7266 Fa x: (858) 560-8929 E-Mail: scsi@paralan.com Copyright 2005 Paralan Corporation All Rights Reserved PRINTED IN THE UNITED STATES OF AMERICA NOTICE: The information in this documentation i s subject to change without notice. PARALA ...

  • Paralan iS521 - page 5

    Page 5 Preface This book is the primary reference and user’s manual for the iS5xx family of SCSI to iSCSI Bridges. It contains a complete functional description of the iSCSI Bridge as well as the complete physical and electrical specifications. It also contains instructions for installing and configuring the iSCSI Bridge. Directions on how to con ...

  • Paralan iS521 - page 6

    Page 6 Revision History VERSION DATE PAGE NO. COMM ENT 1.1 2/6/06 7 Change Appendi ces F to E i n Table of Contents 1.2 2/16/06 35, 36,4 2 Add descri ption of power requ irements for iS520 & iS521. Change EMI/RFI Certifi cation to Class A. Add how to order replacement power supply f or iS520. 1.3 2/21/06 All Upgrade all screen shots. A dded CHA ...

  • Paralan iS521 - page 7

    Page 7 TABLE OF CONT ENTS 1. QUICK INSTALLATION GUIDE………………………………… …... 8-18 2. DESCRIPTION………………………………………………… ………….. 19 3. FEATURES……………………………………………… ………………….19 4. INSTALLATION INSTRUCTIONS……………… …………….. ...

  • Paralan iS521 - page 8

    Page 8 1. QUICK INSTALLA TION GUIDE These instructions will get the user up and running quickl y using the most basic settings and topology. This setup assumes that both y our management and iSCSI host computer are running Windows 2000/XP. It also assumes that you r iSCSI Host computer will be running the Microsoft iSCSI initiator. 1.1 Make sure al ...

  • Paralan iS521 - page 9

    Page 9 1.8 Type in https://192.168.1.200:4443/enter.php as the UR L (see Glossar y) and press enter. The following Login page should appear: 1.9 Enter the default Username and Password and click on the Login tab. 1.9.1 Username: admin 1.9.2 Password: password ...

  • Paralan iS521 - page 10

    Page 10 1.10 You should now be at the Home page. Click on the “iS CSI Target” tab. 1.11 Now you can start configuring y our unit for y our final iSCSI topolo gy (Se e section 1.16 Figure B). Modify the iSCSI Target Port settin gs acc ordin gly. Ensure that the iSCSI Host computer and the iS5xx iSCSI Bridge are on the same subnet. This su bnet m ...

  • Paralan iS521 - page 11

    Page 11 1.12 Confirm changes. 1.13 Once you’ve confirmed changes, the iSCSI Target page will renew with your updated settings. ...

  • Paralan iS521 - page 12

    Page 12 1.14 In order for your settin gs to take affect, you will need to reboot the unit. Cli ck on the Diagnostics tab. On the Diagnostics page, click on “Reboot Device”. The unit will begin reboot after 5 seconds. Wait until the “Status” LED on the Bridge turns solid green. 1.15 Once the iS5xx iSCSI Bridge has rebooted and the “Status? ...

  • Paralan iS521 - page 13

    Page 13 1.17 Connect the SCSI devices to the iS5xx iSCSI Brid ge. 1.17.1 Connect the cable from the SCSI devices to the 68-pin SCSI port on the iS5xx iSCSI Bridge. 1.17.2 Make sure the IDs of the SCSI devices connected to the iS5xx iSCSI Bridge are set to a values other than 7. 1.17.3 Terminate the SCSI bus at the last physical SCSI device. The iS5 ...

  • Paralan iS521 - page 14

    Page 14 1.22 Power on your iSCSI Host computer. Open the Microsoft Initiator. Click on th e “Initiator Settings” tab. Modify your “initiator node name” accordingl y . ...

  • Paralan iS521 - page 15

    Page 15 1.23 Click on the “Target Portals” tab. Add an available portal. ...

  • Paralan iS521 - page 16

    Page 16 1.24 Enter an Address that matches the “IP Address” you entered in step 1.11. Enter the Socket port that matches the “iSCSI Protocol Port” you entered in step 1.11 Click “OK”. ...

  • Paralan iS521 - page 17

    Page 17 1.25 Your Target Portal is now configured. ...

  • Paralan iS521 - page 18

    Page 18 1.26 Click on the “Available Targets” tab. Click on Refresh. After the screen h as refreshed, all available targets through the iS5xx iSCSI Bridge will be displayed. You will need to “Log On” to each one before y our iSCSI Host computer is able to fully communicate with the SCSI targets. If a target drive is to be permanently locate ...

  • Paralan iS521 - page 19

    Page 19 2. DESCRIPTION 2.1 General. Congratulations on yo ur purchase of Paralan’s i S5xx series iSCSI Bridge! Paralan’s family of iSCSI Bridges make it possibl e to merge parallel SCSI storage into IP (iSCSI) Storage Area Netw orks (SANs). If yo u do not have an IP SAN, Paralan’s iSCSI Bridges will easily and inexpensi vely locate storage an ...

  • Paralan iS521 - page 20

    Page 20 3.1.16 256MB SDRAM. 3.1.17 833MHz Freescale processor. 3.1.18 Capable of assigning a unique iSCSI name to each device on the SCSI side of the bus. 3.1.19 Can automatically obtain an IP address from a DHCP server or the user can manually assign an IP address, Subnet mask a nd Gateway to the i SCSI Protocol Port and Web Port. 3.1.20 Diagnosti ...

  • Paralan iS521 - page 21

    Page 21 4.3 SCSI Topology. Paralan’s family of iSCSI Brid ges may be connected an ywhere on the SCSI bus. All models are supplied with on-board terminators enabled. In most cases the iSCSI Bridge will be placed at the end of the SCSI bus and terminators should NOT be disabled (see F igure C). T erm in a ti on SC SI TAP E S CS I R A I D S CS I BUS ...

  • Paralan iS521 - page 22

    Page 22 4.4 SCSI Cables. The most important ingredient in the successful instal lation of any SCSI system is proper cabli ng. Many r ound SCS I cable s are, at best, marginal on single-ended systems and will not work at all on differential SCSI s ystems. Many other round SCSI cables are assembled in a manner that has no re gard for wire pair select ...

  • Paralan iS521 - page 23

    Page 23 4.5 Connecting SCSI Devices. SCSI cable installation i s easy. This installation assumes the topology in Figure C of section 4.3. 4.5.1 Simply connect a SCSI cable into Paralan’s iSCS I Bridge’s 68-pin Hi gh Density “P” SCSI bus Connector (see Image 1 of section 4.2). 4.5.2 Connect the other end of you r cable to y our SCSI device(s ...

  • Paralan iS521 - page 24

    Page 24 4.7 Ethernet Cables. You must choose your Ethernet cable carefull y dependin g upon your configuration. If you are connecting your i SCSI Bridge directly to a management computer, a crossover cable is necessar y. If you are connect ing through an Ethernet switch or router, a straight-throu gh cable will suffi ce. The type of cable used is e ...

  • Paralan iS521 - page 25

    Page 25 4.10 LEDs. There are 5 LEDs on the iSCSI Bridge that can be used for status/diagnostics (see Image 2 of section 4.6) 4.10.1 SCSI Activity (Yellow). The SCSI Activity LED is labeled “SCS I” on the iS520 and iS550. During normal operation, th is LED turns on when there is SCSI activit y on the SCSI bus. How ever, the LED will also indicat ...

  • Paralan iS521 - page 26

    Page 26 4.10.5 Ethernet Link (Yellow/Green). The Ethernet Link LED is labeled “LINK” on the iS520 and iS550. This LED illuminates solid green if the iSCSI Bridge is connected to another active Ethernet component and has negotiated a data transmission rate of 10 or 100Mb/sec. The LED will turn solid yellow fo r a negotiated rate of 1000Mb/sec. 4 ...

  • Paralan iS521 - page 27

    Page 27 4.11.5 The Login page below should appear. Enter your Username and Password and click on the Login tab. The default Username is “admin” and the default Password is “password”. 4.11.6 You should now be at the Home page. You are now read y to confi gure your iSCSI Bridge (see section 5). ...

  • Paralan iS521 - page 28

    Page 28 5. CONFIGURING THROUGH WEB-BAS ED UTILITY 5.1 General. Paralan’s iSCSI Bridge Web-based Util ity conf i gures the unit for many different environments and applications; monitors boot status and updates firmware. Please note that your unit’s serial number is depicted at the upper ri ght hand corner of each web page of the utilit y. 5.1.2 ...

  • Paralan iS521 - page 29

    Page 29 5.3 Diagnostic Page. The Diagnostics Page’s three purposes: 5.3.1 To ensure a clean boot of t he iSCSI Brid ge. If an y part of the iS C SI Bridge unit fails to initialize, it will be indicated on this pa g e. In such an event, refer to the Troubleshooting Appendix E of this book. 5.3.2 The current firmware y our unit is runnin g is also ...

  • Paralan iS521 - page 30

    Page 30 5.4 Web Port Page. By using the Web Port page, the user can modif y the “IP Address”, “Subnet Mask”, “Gatewa y ” and “ W eb Port” settings for the W e b-based Utility. By default, there are two network ports on the iSCSI Bridge connected to the same physical RJ45 connector; the Web Port and the iSCS I Target Port. To simplif ...

  • Paralan iS521 - page 31

    Page 31 5.5 SCSI Bus Page. This page is used to configure certain parameters specific to the SCSI bus interface. Namely: 5.5.1 SCSI ID: You must choose a unique value for thi s ID. No other device on the SCSI bus can have a duplicate ID. 5.5.2 Termination: The iSCSI Brid ge has on-board terminators. You can toggle these terminators on/off via this ...

  • Paralan iS521 - page 32

    Page 32 5.6 iSCSI Target Page. By using the iSCSI Target page, the user can modify the “IP Address”, “Subnet Mask”, “Gatewa y ”, “iSCSI Na me Prefix”, “iSCSI Protocol Port”, “Max Connections” and “Authentication Method” settings for the iSCS I Target on the Bridge. By default, the iSCSI Bridge’s connection t y pe is se ...

  • Paralan iS521 - page 33

    Page 33 5.6.1.1 One-Way CHAP. One-Way CHAP sets a “Username” and “Secret” in the Target (iS5xx iSCSI Brid ge ) that an initiatin g device must use in order for the Target to authenticate the Initiator for communications. You must choose “CHAP” on the “Authentication Method” pull-down menu before you can enable “One-Way” CHAP in ...

  • Paralan iS521 - page 34

    Page 34 5.6.1.2 Mutual CHAP. Mutual CHAP sets a Secret for both the Target (iS5xx iSCSI Bridge) and Initiator. You must choose “ CHAP” on the “Authentication Method” pull-down menu before you can enable “Mutual” CHAP in the “CHAP Direction” pull-d own menu . Once you have done so, you can specify both a Target and Initiat or “User ...

  • Paralan iS521 - page 35

    Page 35 5.7 Updating Firmware. The iS5xx allows y ou to update its firmware via the Web- based Utility. Follow the steps below: 5.7.1 Click on the Admin page tab and click the “Proceed” button. 5.7.2 You will need to choose the file y ou wish to upload usin g t he Browse button and then click the Up gra de button. Once you click the Upgrade but ...

  • Paralan iS521 - page 36

    Page 36 5.7.3 Wait until the “Upgrade Complete” message appe ars and the Status LED returns to a solid green state before continuing to the next file y ou wish to update. If you wish to update an additional file, repeat steps 5.7.1 through 5.7.3. 5.7.4 Once all uploads are complete, reboot the unit via the Diagnostic page or cycle power on the ...

  • Paralan iS521 - page 37

    Page 37 6. APPENDIC ES A. Specifications I. Environmental: a. Relative Humidity: 10-90% non-condensing b. Operating Temperature: 5 - 40 ° C c. Storage Temperature: 0 - 85 ° C d. Airflow (for iS521 only): 10 cubic feet per minute II. Power Requirements: a. iS520 (Stand-Alone Box version). The iS520 is a stand-alone unit in an enclosure with a powe ...

  • Paralan iS521 - page 38

    Page 38 IV. EMI/RFI: • Meets FCC Class A, CE Note: The iS520 uses an external universal power supply (included) that has all required agency approvals. The iS520, iS550 and iS521 use UL listed PC boards and UL compliant parts. V. Physical Dimensions: a. iS520 (Stand-Alone Box version) • Height: 1.6 in (41 mm) • Width: 5.6 in (142 mm) • Dept ...

  • Paralan iS521 - page 39

    Page 39 d. iS521 (Board version). Dimensions are in inches. ...

  • Paralan iS521 - page 40

    Page 40 B. Glossar y CHAP – Challenge-Handshake Authentication Protocol. A form of authentication between iSCSI Initiators and Targets. See One-Way CHAP and Mutual CHAP. Crossover Cable – A network cable that crosses the transmit and receive lines. Typically used to connect computers directl y together, i.e. computer s that a re NOT connected v ...

  • Paralan iS521 - page 41

    Page 41 Target are protected from unauthorized iSCSI access. Mutual CHAP pro vides an added protection over One- W ay CHAP for iSCSI communications on the St orage Network. See CHAP and One-Way CHAP. One-Way CHAP – Username and Secret in the Target (iS5xx iSCSI Bridge) that an initiating device must use in order for the Target to authenticate the ...

  • Paralan iS521 - page 42

    Page 42 URL – Uniform Resource Locator. The address that defines the rout e to a file on an Internet server. URLs are typed into a W eb browser to access Web page s and files. ...

  • Paralan iS521 - page 43

    Page 43 C. Troubleshootin g a. Reset Button. A manual reset switch is located on the LED end of the iSCSI Bridge. On the iS520 (pictured below) and the iS550 (Rac k Mountable version) this switch is accessible through a pinhole on the panel. By pressing this button momentaril y , the user can full y reb oot the unit while maintaining previous user ...

  • Paralan iS521 - page 44

    Page 44 incommunicable. If you have changed the IP Address of the Bridge, make sure that your Management/iSCSI Host computer is on the same subnet as the modified IP Address. If y ou do not remember what settin gs you’ ve modified on your Bridge, you can alwa ys re turn to factor y default settin gs by pressing and holding the reset button down f ...

  • Paralan iS521 - page 45

    Page 45 E. Technical Assistance. For technical assistance contact: Direktronik AB Box 234 149 23 Nynäshamn Sweden Phone: +46 (0)8 524 00 700 Fa x: + 46 (0)8 520 12 181 www.direktronik.se E-Mail: info@direktronik.se A replacement power suppl y for the iS520 can be ordered as Paralan part nu mber 10641-1. ...

Manufacturer Paralan Category Switch

Documents that we receive from a manufacturer of a Paralan iS521 can be divided into several groups. They are, among others:
- Paralan technical drawings
- iS521 manuals
- Paralan product data sheets
- information booklets
- or energy labels Paralan iS521
All of them are important, but the most important information from the point of view of use of the device are in the user manual Paralan iS521.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Paralan iS521, service manual, brief instructions and user manuals Paralan iS521. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Paralan iS521.

Similar manuals

A complete manual for the device Paralan iS521, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Paralan iS521 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Paralan iS521.

A complete Paralan manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Paralan iS521 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Paralan iS521, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Paralan iS521, that we can find in the current document
3. Tips how to use the basic functions of the device Paralan iS521 - which should help us in our first steps of using Paralan iS521
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Paralan iS521
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Paralan iS521 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Paralan iS521?

Use the form below

If you did not solve your problem by using a manual Paralan iS521, ask a question using the form below. If a user had a similar problem with Paralan iS521 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)