  • Emerson MMI-20016185 - page 1

    Installation Manual P/N MMI-20016185, Rev. AA January 2010 Micro Motion ® 9739 MVD Transmitters Installation Manual Planning Mounting Wiring ...

  • Emerson MMI-20016185 - page 2

    Safety and approval information This Micr o Motion product complies with all applicable Eur opean dir ectives when pr operly ins talled in acc ordance with the instructions in this manual. Ref er to the E C declaration of conf ormity f or directiv es tha t apply to this pr oduct. The E C declaration of conf ormity , with all applicable European dir ...

  • Emerson MMI-20016185 - page 3

    Contents Chapter 1 Planning ......................................................................................................... 1 Installa tion checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Emerson MMI-20016185 - page 4

    ...

  • Emerson MMI-20016185 - page 5

    Chapter 1 Planning Topics covered in this chapter: ¨ Installa tion checklist ¨ 9739 MVD transmit ter c omponents Installation checklist q Mak e sure that the tr ansmitt er is suit able for the en vironment in which it will be inst alled. See the haz ardous ar ea specied on the transmitt er appr ov al t ag. q Locate and moun t the transmitt er ...

  • Emerson MMI-20016185 - page 6

    Planning Figure 1-1 Standard housing lockout clamp components (ATEX installations only) A B C D E F A Housing cover B Lip C Mounting screw D Clamp E Threaded hole F Housing base Notes • Bef ore inst alling the tr ansmitt er housing lock out clamp, mak e sur e that you ha ve properly ins talled the tr ansmitter and the owmeter has been zer oed. ...

  • Emerson MMI-20016185 - page 7

    Planning Figure 1-2 Components of the 9739 MVD transmitter A G F B C E H D I A Remov able housing cover B Electronics module C Intrinsically sa fe sensor wiring terminals D Non–intrinsically-saf e output wiring terminals E Conduit opening f or sensor wiring F Conduit opening for power supply wiring G Conduit opening f or output wiring H Housing b ...

  • Emerson MMI-20016185 - page 8

    Chapter 2 Mounting Topics covered in this chapter: ¨ Mount the 9739 MVD transmit ter to a wall ¨ Moun t the 9739 MVD tr ansmitt er t o an instrumen t pole ¨ Rota te the user int erf ace on the electronics module (op tional) Mount the 9739 MVD transmitter to a wall Prerequisites • Use f our 5/16-inch diameter (or M8) bolts and nuts that c an wi ...

  • Emerson MMI-20016185 - page 9

    Mounting Figure 2-1 Transmitter mounting dimensions (front and side views) B E A D C F A 2.81 inches (71 mm) B 7.31 inches (186 mm) C 4.51 inches (115 mm) D 8.39 inches (213 mm) E 9.19 inches (233 mm) F With display: 6.82 inches (173 mm); Without displa y: 7.28 inches (185 mm) Figure 2-2 Transmitter mounting dimensions (bottom view) A B C D E A 0.1 ...

  • Emerson MMI-20016185 - page 10

    Mounting Mount the 9739 MVD transmitter to an instrument pole Prerequisites • Use two 5/16-inch U-bolts for 2-inch pipe, and f our matching nuts, that c an withstand the pr ocess envir onment. Micro Motion does not supply U-bolts or nuts. • Ensure the instrument pole ext ends at least 12 inches (305 mm) from a rigid base, and is no more than 2 ...

  • Emerson MMI-20016185 - page 11

    Mounting Rotate the user interface on the electronics module (optional) The user int erface on the tr ansmitt er electronics module can be r ota ted 180 ° fr om the original position. Procedure 1. Shut of f power to the unit. 2. Unscrew and remove the transmitt er housing cov er . If the tr ansmitt er is ins talled in a haz ardous area, be sur e y ...

  • Emerson MMI-20016185 - page 12

    Chapter 3 Wiring the power supply and grounding the transmitter Topics covered in this chapter: ¨ P ower supply r equiremen ts ¨ Wire the pow er supply ¨ Gr ound the 9739 MVD transmit ter Power supply requirements The 9739 MVD tr ansmitt er can accept either AC or DC power . The transmit ter automa tically recogniz es the source v oltage. T able ...

  • Emerson MMI-20016185 - page 13

    Wiring the power supply and grounding the transmitter Figure 3-1 Power supply wiring terminals E B C D A A External gr ound terminal B Pow er supply conduit opening C L / L1 for AC; + f or DC D N / L2 for AC; – f or DC E Pow er ground terminal 5. Secure the input power connections at the two labeled t erminals. For A C-powered tr ansmitt ers, y o ...

  • Emerson MMI-20016185 - page 14

    Wiring the power supply and grounding the transmitter Important Follow the plan t st andards if a separa te high-in tegrity intrinsically saf e gr ound scheme is used. If national s tandar ds or plant standar ds are not in e ff ect, adhere to the f ollowing guidelines f or grounding: • Use copper wire, 14 A WG (2.5 mm 2 ) or larger wire siz e. ? ...

  • Emerson MMI-20016185 - page 15

    Chapter 4 Wiring the 9739 MVD transmitter to the sensor Topics covered in this chapter: ¨ Prepar e the 9-wire c able ¨ Wir e the tr ansmitt er t o the sensor using jack et ed c able ¨ Wire the tr ansmit ter to the sensor using shielded or armored cable ¨ Sensor and tr ansmit ter t erminals ¨ Micr o Motion 9-wire c able types and usage Prepare ...

  • Emerson MMI-20016185 - page 16

    Wiring the 9739 MVD transmitter to the sensor Figure 4-1 Preparing jacketed cable 12 Micro Motion 9739 MVD Transmitters ...

  • Emerson MMI-20016185 - page 17

    Wiring the 9739 MVD transmitter to the sensor Figure 4-2 Preparing shielded or armored cable Installation Manual 13 ...

  • Emerson MMI-20016185 - page 18

    Wiring the 9739 MVD transmitter to the sensor Wire the transmitter to the sensor using jacketed cable Prerequisites For A TEX installa tions, the jack eted cable must be inst alled inside a user-supplied sealed met allic conduit that pr ovides 360 ° termination shielding f or the enclosed cable. Sensor wiring is intrinsically sa fe. T o k eep sens ...

  • Emerson MMI-20016185 - page 19

    Wiring the 9739 MVD transmitter to the sensor Table 4-2 Sensor and transmitter terminal designations Wire color Sensor terminal Transmitter terminal Function Black No connection 0 Drain wires Brown 1 1 Drive + Red 2 2 Drive − Orange 3 3 T emper ature − Y ellow 4 4 T emper ature re turn Green 5 5 Left pick off + Blue 6 6 Right pick of f + Violet ...

  • Emerson MMI-20016185 - page 20

    Wiring the 9739 MVD transmitter to the sensor Figure 4-3 Cable gland and cable (exploded view) A B C D E F G H I A Cable B Sealing nut C Compression nut D Brass compr ession ring E Braided shield F Cable G T ape or heat-shrink tubing H Clamp seat (shown as int egral t o nipple) I Nipple 3. Unscrew the nipple fr om the compression nut. 4. Screw the ...

  • Emerson MMI-20016185 - page 21

    Wiring the 9739 MVD transmitter to the sensor Figure 4-4 Cross-section of assembled cable gland with cable A B C D E F G A A Cable B Sealing nut C Seal D Compression nut E Braided shield F Brass compression ring G Nipple 10. Remov e the junction-bo x cover or transmit ter housing cover . 11. At both the sensor and tr ansmitt er , c onnect the cable ...

  • Emerson MMI-20016185 - page 22

    Wiring the 9739 MVD transmitter to the sensor Table 4-3 Sensor and transmitter terminal designations continued Wire color Sensor terminal Transmitter terminal Function Violet 7 7 T emper ature + Gra y 8 8 Right pick of f − White 9 9 Left pick off − b. Tight en the scr ews to hold the wires in place. c. Ensur e int egrity of g ask ets, gr ease a ...

  • Emerson MMI-20016185 - page 23

    Wiring the 9739 MVD transmitter to the sensor Figure 4-6 F-Series, Model D, and Model DL sensor terminals Figure 4-7 Model DT sensor terminals (user-supplied metal junction box with terminal block) 1 9 8 7 6 5 4 3 2 A A Earth gr ound Figure 4-8 9739 MVD transmitter terminals Installation Manual 19 ...

  • Emerson MMI-20016185 - page 24

    Wiring the 9739 MVD transmitter to the sensor Micro Motion 9-wire cable types and usage Cable types Micro Motion supplies three types of 9-wir e cable: jacketed, shielded, and armored. Note the following diff er ences between the cable types: • Armored cable provides mechanical protection f or the cable wires. • Jacket ed cable has a smaller be ...

  • Emerson MMI-20016185 - page 25

    Wiring the 9739 MVD transmitter to the sensor Table 4-6 Bend radii of shielded cable Minimum bend radii Jacket material Outside diameter Static (no load) condition Under dynamic load PVC 0.2 inches (14 mm) 4–1/4 inches (108 mm) 8–1/2 inches (216 mm) T eon FEP 0.425 inches (11 mm) 3–1/4 inches (83 mm) 6–3/8 inches (162 mm) Table 4-7 Bend ...

  • Emerson MMI-20016185 - page 26

    Wiring the 9739 MVD transmitter to the sensor Figure 4-10 Cross-section view of shielded cable A C (1) B D E (4) F (4) G (5) A Outer jack et B Tin-plated c opper braided shield C Foil shield (1 tot al) D Inner jacke t E Drain wir e (4 total) F Foil shield (4 total) G Filler (5 total) 22 Micro Motion 9739 MVD Transmitters ...

  • Emerson MMI-20016185 - page 27

    Wiring the 9739 MVD transmitter to the sensor Figure 4-11 Cross-section view of armored cable A C (1) B D E (4) F (4) G (5) A Outer jack et B Stainless st eel braided shield C Foil shield (1 tot al) D Inner jacke t E Drain wir e (4 total) F Foil shield (4 total) G Filler (5 total) Installation Manual 23 ...

  • Emerson MMI-20016185 - page 28

    Chapter 5 Wiring the outputs Topics covered in this chapter: ¨ Analog output terminals ¨ Wir e the primary and secondary mA outputs ¨ Wire the frequency/pulse output ¨ Wire the discr ete output ¨ Wire the discr ete input ¨ Wire to a pressur e tr ansmitt er Analog output terminals Use the upper and lower terminal blocks on the right side of th ...

  • Emerson MMI-20016185 - page 29

    Wiring the outputs Figure 5-1 Analog output terminals Table 5-8 Analog output wiring terminal designations Terminal Function 14 Frequency output, DC supply v oltage (+) 15 and 16 Frequency/pulse output (+) 16 Return 17 Primary variable (P V+) mA output 18 Primary variable (P V–) mA output 19 Secondary variable (SV+) mA output 20 Secondary variabl ...

  • Emerson MMI-20016185 - page 30

    Wiring the outputs Wire the primary and secondary mA outputs Use t erminals 17 and 18 f or the primary mA output. Use t erminals 19 and 20 f or the secondary mA output. The mA outputs produce a user-selected 0–20 mA or 4–20 mA current. When congur ed as 4–20 mA outputs, the mA outputs can supply loop-powered process indica tors. The primar ...

  • Emerson MMI-20016185 - page 31

    Wiring the outputs Figure 5-3 Wiring the primary mA output for HART communications A B PV+ PV - R1 R3 R2 C 17 18 A HART c ommunications tool, Pr oLink II, or AMS modem B Communicator loops or PV (Primary V ariable) terminals C DCS or PLC with internal r esistor Notes • If necessary , add resist ance in the loop by installing a r esistor R1. SMART ...

  • Emerson MMI-20016185 - page 32

    Wiring the outputs Figure 5-4 Wiring the frequency/pulse output A B C A FREQ+ B RETURN C PLC or pulse count er • T o c ongure the output for increased curren t, add a 1 t o 3 k Ω resis tor across terminals 14 and 15 (see Figur e 5-5). Figure 5-5 Wiring the frequency/pulse output for increased current B C D A A 1 to 3 kΩ resist or B FREQ+ C ...

  • Emerson MMI-20016185 - page 33

    Wiring the outputs Figure 5-6 Wiring the frequency/pulse output for constant current A B D C A FREQ+ B RETURN C 100 to 250 Ω resis tor D PLC or pulse count er • T o wire the output to use external power , see Figure 5-7 . F or recommended resis tor ver sus supply voltage, see Figure 5-8 . Do not exceed 30 VDC input. Excessiv e current will dama ...

  • Emerson MMI-20016185 - page 34

    Wiring the outputs Figure 5-7 Wiring the frequency/pulse output for external power A B E C D A FREQ+ B RETURN C A pull-up r esistor , which mus t be of sufcien t v alue to limit loop current to less than 500 mA depending on the t otal loop resist ance at the tr ansmitter D 3 to 30 VDC power supply E PLC or pulse count er Figure 5-8 Recommended p ...

  • Emerson MMI-20016185 - page 35

    Wiring the outputs Wire the discrete output The discret e output c an indicat e the ow direction, tr ansmit ter z eroing in pr ogress, pr essure input failur e, f aults, even t 1 or even t 2. Y ou can wire the discre te output to use int ernal or e xternal po wer . See Micro Motion 9739 MVD T ransmitters: Conguration and Use Manual f or more ...

  • Emerson MMI-20016185 - page 36

    Wiring the outputs Figure 5-10 Wiring the discrete output for external power A B A A pull-up resist or , which must be of suf cient v alue to limit loop current to less than 500 mA depending on t otal loop resist ance at the tr ansmitter B 3 to 30 VDC power supply Figure 5-11 Recommended pull-up resistor versus supply voltage (external power) Wi ...

  • Emerson MMI-20016185 - page 37

    Wiring the outputs Figure 5-12 Wiring the discrete input - + A A Remot e switch Wire to a pressure transmitter The 9739 MVD tr ansmitt er accepts inputs fr om a pressur e transmit ter f or pressur e compensa tion. Because the pr essure tr ansmitt er wiring is not in trinsically saf e, k eep the pressur e tr ansmitter wiring separ ated from the pow ...

  • Emerson MMI-20016185 - page 38

    Wiring the outputs • If the pressure tr ansmitt er requir es a power supply gr eater than 13.6 V , or if other loop devices are r equired, y ou can use an ext ernal source to pow er the pr essure tr ansmitt er . Use t erminals S and 23 (see Figur e 5-14). Figure 5-14 Wiring to a pressure transmitter — external power, analog input A B D 4-20 mA ...

  • Emerson MMI-20016185 - page 39

    Wiring the outputs Figure 5-15 Wiring to a pressure transmitter — digital communications A B C D 24 V D C A Pressur e transmit ter , with HAR T only B 250 Ω ± 5 %, 0.5 W C 250 Ω ± 5 %, 0.5 W D DC power supply Installation Manual 35 ...

  • Emerson MMI-20016185 - page 40

    Chapter 6 Wiring digital communications Topics covered in this chapter: ¨ Wir e the tr ansmitt er t o an RS-485 multidrop network ¨ Wir e the tr ansmitt er t o a Bell 202 multidrop network Wire the transmitter to an RS-485 multidrop network Prerequisites Use twis ted-pair , shielded cable that consis ts of 24 A WG (0.25 mm 2 ) or larger wir e bet ...

  • Emerson MMI-20016185 - page 41

    Wiring digital communications Choose from the following options for wiring the RS-485 network: • T o connect one tr ansmitter to a hos t con troller f or the R S-485 serial communic ation, see Figur e 6-1. Figure 6-1 Wiring a 9739 MVD transmitter to a host controller 9739 26 27 A B R S-485 • T o connect multiple tr ansmitt ers t o a hos t contr ...

  • Emerson MMI-20016185 - page 42

    Wiring digital communications Figure 6-3 Wiring to a typical HART ® network P V + 17 PV – 18 PV + C N 2- Z 30 PV – C N 2- D 30 4-20 mA 4 -20 mA 24 V D C 9739 9739 A B C D E E F A HART c ommunications tool, Pr oLink II, or AMS modem B 250 Ω load C IFT9701 D R-Series E SMART F AMIL Y ® transmit ter F DC source r equired for other HAR T 4–20 ...

  • Emerson MMI-20016185 - page 43

    ...

  • Emerson MMI-20016185 - page 44

    © 2010, Micro Motion, Inc. All rights r eserved. P /N MMI-20016185, R ev . AA *MMI-20016185* For the lat est Micr o Motion product specica tions, view the PRODUCTS section of our web site at www .micr omotion.com Micro Micro Micro Motion Motion Motion Inc. Inc. Inc. USA USA USA W orldwide Headquart ers 7070 Winches ter Circle Boulder , Color ad ...

Manufacturer Emerson Category Satellite Radio

Documents that we receive from a manufacturer of a Emerson MMI-20016185 can be divided into several groups. They are, among others:
- Emerson technical drawings
- MMI-20016185 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson MMI-20016185
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson MMI-20016185.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson MMI-20016185, service manual, brief instructions and user manuals Emerson MMI-20016185. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson MMI-20016185.

Similar manuals

A complete manual for the device Emerson MMI-20016185, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson MMI-20016185 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson MMI-20016185.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson MMI-20016185 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson MMI-20016185, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson MMI-20016185, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson MMI-20016185 - which should help us in our first steps of using Emerson MMI-20016185
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson MMI-20016185
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson MMI-20016185 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson MMI-20016185?

Use the form below

If you did not solve your problem by using a manual Emerson MMI-20016185, ask a question using the form below. If a user had a similar problem with Emerson MMI-20016185 it is likely that he will want to share the way to solve it.

Copy the text from the picture