    VX-2100E S ERIES O PERA TING M ANUAL VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU EUROPE B.V. P.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD. Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO2 ...

  • Vertex Standard VX-2100E - page 2

    Unsafe Radiation Distance Congratulations! Y ou now have at your fingertips a valuable communications tool: a VER TEX ST AN- DARD two-way radio! Rugged, reliable and easy to use, your VER TEX ST ANDARD radio will keep you in constant touch with your colleagues for years to come, with negligible maintenance downtime. Please take a few minutes to rea ...

  • Vertex Standard VX-2100E - page 3

    VX-2100E S ERIES O PERA TING M ANUAL 1 I NTRODUCTION The VX-2100E Series are full-featured FM transceiver designed for flexible mo- bile and base station business communications in the VHF or UHF Land Mobile bands. These transceiver are designed for reliable business communications in a wide variety of applications with a wide range of operating ca ...

  • Vertex Standard VX-2100E - page 4

    VX-2100E S ERIES O PERA TING M ANUAL 2 C ONTROLS & C ONNECTORS Front Panel Important! - All buttons located on the Front Panel are Programmable Function (PF) Buttons, configured according to your network requirements and programmed by your VER TEX ST ANDARD dealer . The instructions below describe a typically- configured radio. c VOL/PWR Knob T ...

  • Vertex Standard VX-2100E - page 5

    VX-2100E S ERIES O PERA TING M ANUAL 3 g Channel Number Indicator Indicates the operating channel. Blinks the squelch setting level (0-9, A, b, and C) while adjusting the squelch threshold level. Appear the decimal point “.” when selecting the Scan enabel channel. h T ransceiver S tatus Indicator The “ A ” and “ B ” indicators show curr ...

  • Vertex Standard VX-2100E - page 6

    VX-2100E S ERIES O PERA TING M ANUAL 4 Rear Panel C ONTROLS & C ONNECT ORS c 13.6V DC Cable Pigtail with Connector The supplied DC power cable must be connected to this 2-pin connector . Use only the supplied fused cable, extended if necessary , for power connection. d Antenna Socket The 50-Ohm coaxial feedline to the antenna must be connected ...

  • Vertex Standard VX-2100E - page 7

    VX-2100E S ERIES O PERA TING M ANUAL 5 B ASIC O PERA TION OF THE T RANSCEIVER Important! - Before turning on the radio the first time, confirm that the power connections have been made correctly and that a proper antenna is connected to the antenna jack. Switching Power ON/OFF  T urn the VOL/PWR knob turn on the radio. The display will become il ...

  • Vertex Standard VX-2100E - page 8

    VX-2100E S ERIES O PERA TING M ANUAL 6 Automatic Time-Out Timer If the selected channel has been programmed for automatic time-out, you must limit the length of each transmission. While transmitting, a beep will sound 10 seconds before time-out. Another beep will sound just before the deadline; the red “ TX ” indicator will disappear and transm ...

  • Vertex Standard VX-2100E - page 9

    VX-2100E S ERIES O PERA TING M ANUAL 7 Ú : Requires optional unit PF Button ( P RESS K EY / P RESS AND H OLD K EY ) Function MONI SQL OFF SQL SET Channel Up Channel Down Continuous Ch Up Continuous Ch Down SCAN SCAN SET DW (Dual W atch) Follow-Me SCAN Follow-Me DW LOW T A (T alk Around) T A SCAN Encryption Ú Emergency RESET CALL 1 CALL 2 CALL 3 P ...

  • Vertex Standard VX-2100E - page 10

    VX-2100E S ERIES O PERA TING M ANUAL 8 Description of Operating Functions M ONITOR ( MONI ) Press (or press and hold) the assigned programmable key to cancel CTCSS- and DCS-controlled squelch; the TX/BUSY indicator will glow green S QUELCH ( SQL ) O FF Press (or press and hold) the assigned programmable key to open the SQL to hear background noise ...

  • Vertex Standard VX-2100E - page 11

    VX-2100E S ERIES O PERA TING M ANUAL 9 A DV ANCED O PERA TION C HANNEL S CAN ( SCAN ) The Scanning feature is used to monitor multiple channels programmed into the trans- ceiver . While scanning, the transceiver will check each channel for the presence of a signal, and will stop on a channel if a signal is present. T o activate scanning:  Press ...

  • Vertex Standard VX-2100E - page 12

    VX-2100E S ERIES O PERA TING M ANUAL 10 F OLLOW -M E S CAN “Follow-Me” Scan feature checks a User-assigned Priority Channel regularly as you scan the other channels. Thus, if only Channels 1, 3, and 5 (of the 8 available chan- nels) are designated for “Scanning,” the user may nonetheless assign Channel 2 as the “User-assigned” Priority ...

  • Vertex Standard VX-2100E - page 13

    VX-2100E S ERIES O PERA TING M ANUAL 11 T ALK A ROUND ( TA ) Press (or press and hold) the assigned programmable key to activate the T alk Around feature when you are operating on duplex channel systems (separate receive and transmit frequencies, utilizing a “repeater” station). The T alk Around feature allows you to bypass the repeater station ...

  • Vertex Standard VX-2100E - page 14

    VX-2100E S ERIES O PERA TING M ANUAL 12 P UBLIC A DDRESS Press the assigned programmable key to use the transceiver as a P A amplifier. When you enable this function, a tone sounds. The public address can be used even while scanning and receiving a call. EXT . ACC1 Press (or press and hold) the assigned programmable key to toggle output port “1? ...

  • Vertex Standard VX-2100E - page 15

    VX-2100E S ERIES O PERA TING M ANUAL 13 K EY L OCK Press (or press and hold) the assigned programmable key to lock the various aspects of the VX-2100E ’ s keys. The precise lockout configuration must be programmed by your VER TEX ST ANDARD dealer . AR TS (Auto Range T ranspond System) This system is designed to inform you when you and another AR ...

  • Vertex Standard VX-2100E - page 16

    VX-2100E S ERIES O PERA TING M ANUAL 14 O PTIONAL A CCESSORIES MH-67 A8J Standard Microphone MH-25 A8J S tandard Microphone MH-64 A8J 16 Keypad Microphone MD-1 1 A8J Desktop Microphone MLS-100 External Speaker (12 W Peak Power) MLS-200 External Speaker (15 W Peak Power) FP-1023A External Power Supply (13.8 VDC 23 A) FVP-25 DTMF Paging/V oice Invers ...

  • Vertex Standard VX-2100E - page 17

    VX-2100E S ERIES O PERA TING M ANUAL 15 N OTES ...

  • Vertex Standard VX-2100E - page 18

    VX-2100E S ERIES O PERA TING M ANUAL 16 N OTES ...

  • Vertex Standard VX-2100E - page 19

    Declaration of Conformity We, Y aesu Europe B.V . declare under our sole responsibility that the following equipment complies with the essential requirements of the Directive 1999/5/EC. T ype of Equipment: FM Transceiver Brand Name: VER TEX ST ANDARD Model Number: VX-2100E/2200E Series Manufacturer: V ertex St andard Co., Ltd. Address of Manufactur ...

  • Vertex Standard VX-2100E - page 20

    Copyright 2006 VERTEX STANDARD CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. EC061N200 ...

Manufacturer Vertex Standard Category Car Stereo System

Documents that we receive from a manufacturer of a Vertex Standard VX-2100E can be divided into several groups. They are, among others:
- Vertex Standard technical drawings
- VX-2100E manuals
- Vertex Standard product data sheets
- information booklets
- or energy labels Vertex Standard VX-2100E
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vertex Standard VX-2100E.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vertex Standard VX-2100E, service manual, brief instructions and user manuals Vertex Standard VX-2100E. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vertex Standard VX-2100E.

A complete manual for the device Vertex Standard VX-2100E, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vertex Standard VX-2100E by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vertex Standard VX-2100E.

A complete Vertex Standard manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vertex Standard VX-2100E - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vertex Standard VX-2100E, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vertex Standard VX-2100E, that we can find in the current document
3. Tips how to use the basic functions of the device Vertex Standard VX-2100E - which should help us in our first steps of using Vertex Standard VX-2100E
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vertex Standard VX-2100E
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vertex Standard VX-2100E in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vertex Standard VX-2100E?

Use the form below

If you did not solve your problem by using a manual Vertex Standard VX-2100E, ask a question using the form below. If a user had a similar problem with Vertex Standard VX-2100E it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)