Manual Grindmaster RAPS-430

12 pages 0.23 mb
Download

Go to site of 12

Summary
  • Grindmaster RAPS-430 - page 1

    ICB-400, ICB-300, P-430, P-330, RAP-430, RAP-330, RAPS-430, RAPS-330 OPER ATIONS MANUAL INS TALLATION WARNING: ELECTRIC SHOCK HAZARD! Installation of this appliance should be performed by qualified service personnel onl y . Improper installation could result in electrocution. SET-UP AND POSITIONING OF BREWER • Remove the brewer from packaging mat ...

  • Grindmaster RAPS-430 - page 2

    AMERICAN ME TAL WARE ® BREWERS INITIAL START-UP (cont’d) Once the appropriate selection is made, press the S TART switch on the touchpad to begin dispensing water through the sprayhead. Brew at least 1 batch for each timer setting. Check the level in the container to be sure the brew volume is correct. Remember that when using coffee, the level ...

  • Grindmaster RAPS-430 - page 3

    AMERICAN ME TAL WARE ® BREWERS TEMPER ATURE AND BREW TIMING CONTROLS (Refer to Figure C) Temperature and brew timing are set by the dial and keypad located on the main controller. This controller is positioned inside the brewer housing and is accessed by removing the screws which fasten the access panel to the brewer. The controller stores 6 indep ...

  • Grindmaster RAPS-430 - page 4

    STANDARD FE ATURES Three options are available on this equipment; these options are available independently of each other. The features are described below: Pre-infusion: This option enables the brewer to wet the grounds and then have a dwell period before the brew cycle is completed. This option causes the brew valve to open for a period of time, ...

  • Grindmaster RAPS-430 - page 5

    BY PASS ADJUSTMENT (Refer to Figure D) The bypass valve adjusts the amount of water that bypasses coffee grounds and dilutes the final brew. The factory setting is no bypass. Bitter coffee results when the amount of ground coffee is too small. Therefore, if coffee is too strong, it is better to adjust the bypass rate instead of reducing the amount ...

  • Grindmaster RAPS-430 - page 6

    AMERICAN ME TAL WARE ® BREWERS TROUBLESHOOTING GUIDE Problem Possible Cause Solution ERROR MESSAGE FILLING PROBLEMS • Check system for water leaks. Correct any leaks and reset controller. • Thermistor failure or loose connections in thermistor circuit. • Fill valve not sealing properl y. • Fill valve installed backwards. • High electrode ...

  • Grindmaster RAPS-430 - page 7

    HE ATING PROBLEMS Tank does not heat • No electrical power to equipment. • No power to control board. • High electrode coated with lime or fault y. • Connection from control board to tank body fault y. • Connections from control board to heater relay fault y. • Check for proper voltage at terminal block. Check circuit breaker on supply ...

  • Grindmaster RAPS-430 - page 8

    AMERICAN ME TAL WARE ® BREWERS TROUBLESHOOTING GUIDE (cont’d) • Contactor fault y. • Heater fault y. • Control board is fault y . • Heater fault y. Tank does not heat (cont’d) Brew recovery time is very long Brew volume too large or too small • Ensure that coil on heater relay is energized by ensuring that there is 12 Vac between the ...

  • Grindmaster RAPS-430 - page 9

    P roblem Possible Cause Solution • Brew valve fault y. • Touchpad fault y. • Controller fault y. • Check to see if there is 120 Vac across brew valve terminal. If there is 120 Vac across terminals and brew valve is not open,replace valve. • Check to see that touchpad connections to control board are secure. If connections are secure, othe ...

  • Grindmaster RAPS-430 - page 10

    AMERICAN ME TAL WARE ® BREWERS P-430, P-330, ICB-400, ICB-300 Part # A515027 A530-051 A531-072 A531-073 A535-071 A535-059 A536-018 A537-129 A537-154 A554-101 A712-066 A712-170 A712-174 DESCRIPTION Rela y , 12V d.c. Coil Controller Rela y , Powe r, 115V Coil Switch, Red Stop Element, Heating 6.6kw 240 Vac Element, Heating 6.6kw 240 Vac Probe, Therm ...

  • Grindmaster RAPS-430 - page 11

    AMERICAN ME TAL WARE ® BREWERS NOTES Page 11 ...

  • Grindmaster RAPS-430 - page 12

    WARRANTY For Models ICB-400, ICB-300, P-430, P-330 RAP-430, RAP-330, RAPS-430, RAPS-330 EFFECTIVE OCTOBER 1, 1998 GENERAL WARRANTY INFORM ATION Grindmaster Corporation maintains the highest standard of quality control in the manufacturing of American Metal Ware products. We use the finest components and materials, and employ quality engineering sta ...

Manufacturer Grindmaster Category Coffeemaker

Documents that we receive from a manufacturer of a Grindmaster RAPS-430 can be divided into several groups. They are, among others:
- Grindmaster technical drawings
- RAPS-430 manuals
- Grindmaster product data sheets
- information booklets
- or energy labels Grindmaster RAPS-430
All of them are important, but the most important information from the point of view of use of the device are in the user manual Grindmaster RAPS-430.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Grindmaster RAPS-430, service manual, brief instructions and user manuals Grindmaster RAPS-430. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Grindmaster RAPS-430.

A complete manual for the device Grindmaster RAPS-430, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Grindmaster RAPS-430 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Grindmaster RAPS-430.

A complete Grindmaster manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Grindmaster RAPS-430 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Grindmaster RAPS-430, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Grindmaster RAPS-430, that we can find in the current document
3. Tips how to use the basic functions of the device Grindmaster RAPS-430 - which should help us in our first steps of using Grindmaster RAPS-430
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Grindmaster RAPS-430
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Grindmaster RAPS-430 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Grindmaster RAPS-430?

Use the form below

If you did not solve your problem by using a manual Grindmaster RAPS-430, ask a question using the form below. If a user had a similar problem with Grindmaster RAPS-430 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)