Manual Invacare MA80

24 pages 0.55 mb
Download

Go to site of 24

Summary
  • Invacare MA80 - page 1

    Owner’s Operator and Maintenance Manual DEALE R: This manual M UST be given to the user of th e product. USER: BEFORE using this product, read this manual an d save for future reference. For mo re inform ation reg arding In va ca re p ro du cts , pa rts, and services, please v isit www.inva care.com MA80 Series MA80 True Low Air Loss System MA85 ...

  • Invacare MA80 - page 2

    SPECIAL NOTES MA80 Series 2 Part No 1148138  WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any addition al instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you ...

  • Invacare MA80 - page 3

    TABL E OF CON TENT S Part No 1148138 3 MA80 Series TABLE OF CONTENT S SPE CI AL NOT ES ..... ...... ...... ...... ....... ...... ...... ...... ....... ...... ...... ...... ...... . 2 REGISTER YO UR PRODUCT ..... ..... ...... ...... ...... ...... ..... ...... ...... ........ .... 4 TYP ICA L P RO DUC T P ARAM ET ERS ...... ...... ...... ...... ..... ...

  • Invacare MA80 - page 4

    TABLE OF CONTENTS MA80 Series 4 Part No 1148138 TABLE OF CONTENT S Transferring Patient Fr om/To a Gurney ............ ........................... ........................... ...........................19 Transferring Patient Fr om/To a Wheelchair ....................... ........................... ........................... ......... 19 Preparing ...

  • Invacare MA80 - page 5

    TYPICAL PRODUCT PARAMETERS Part No 1148138 5 MA 80 Se rie s TYPICAL PRODUCT PARAMETERS Electric al Paramet ers Performanc e Paramete rs Mechanical P arameters MA80/MA85 INPUT VOLTAGE AC: 90 V INPUT FREQUEN CY: 60 H z CURRENT: 2 A MAXIMU M POWER CONSU MPTION: 150 ± 10 W CIRCUIT PROTECTION: Dual fused, 250 V, 5 A fast blow fuses MODE OF OPERATION: C ...

  • Invacare MA80 - page 6

    TYPICAL PRODUCT PARAMETERS MA80 Series 6 Part No 1148138 Environment al Paramet ers MA80/MA85 OPERATING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: 50° - 104° F 30% - 75% Non-Condensing 70 - 106 kPa STORAGE AND SHIP PING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: -40° - 158° F 10% - ...

  • Invacare MA80 - page 7

    LABEL LOCATION Part No 1148138 7 MA 80 Se rie s LABEL LOCAT ION DANGER-EXPLOSION HAZARD: DO NOT us e in the presence of flammable anesthetics. CAUTION: Eq uipment should be connected to a properly grounded receptacle (3-prong). Risk of Electrical shock. DO NOT remove back. Disconnect air hose before administering CPR. NOTE: This label is on the bac ...

  • Invacare MA80 - page 8

    SECTION 1—GENERAL GUIDELINES MA80 Series 8 Part No 1148138 SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the s afe operation and use of this product. Contraindications ALW AYS consult the patient’ s physi cian b efore using the MA80 and MA85 systems. Installation The MA80 and MA85 s ...

  • Invacare MA80 - page 9

    SECTION 1—GENERAL GUIDELINES Part No 1148138 9 MA 80 Se rie s Fire Hazard  DANGER Smoking DO NOT SMOKE while using this device. This system uses r oom air for circulation through the mattress. A cigarett e can burn a hole i n the bed surface and cause damage to the m attress. Also, p atient cl othing, bed sheets, etc. may be combustible and ca ...

  • Invacare MA80 - page 10

    SECTION 2—OPERATION MA80 Series 10 Part No 1148138 SECTION 2—OPERATION CAUTION The control unit and mattress on the MA80 series are designed to be used as a system. DO NOT replace mattresses or control units with other models or other brands. Otherwise, damage to the system m ay occur. Contact your supplier to get the correct replacement if nee ...

  • Invacare MA80 - page 11

    SECTION 2—OPERATION Part No 1148138 11 MA80 Se rie s FIGURE 2.1 Installing the Mattress Replacement System Installing the Side R ails  WARNING Patient entrapment with bed side rails may cause injury or death. Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment. Follow the manufacturer’s instructions. Monitor patie ...

  • Invacare MA80 - page 12

    SECTION 2—OPERATION MA80 Series 12 Part No 1148138 Connecting the Hose CAUTION Ensure that the hose connecting the control unit to the mattress i s routed such t hat it cannot be stepped on, kinked, squeezed or otherwise damaged. NOTE: For this pr ocedure, r efer to FIGURE 2.3. 1. Locate the hose at the foo t end of the mattress. 2. Locate the co ...

  • Invacare MA80 - page 13

    SECTION 2—OPERATION Part No 1148138 13 MA80 Se rie s Connecting the Power Cord  WARNING DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is ...

  • Invacare MA80 - page 14

    SECTION 2—OPERATION MA80 Series 14 Part No 1148138 Using the Front Panel NOTE: For this pr ocedure, r efer to FIGURE 2.5. FIGURE 2.5 Using the Front Panel Power Butt on 1. T o turn the contro l uni t on or off, press and release the P ower butt on ( ). NOTE: Once the u nit is plugged in, an A MBER LED on t he contr ol unit is lit indic ating that ...

  • Invacare MA80 - page 15

    SECTION 2—OPERATION Part No 1148138 15 MA80 Se rie s Pulse Butto n (MA80) 1. Press the Pulse button ( ) to T urn on Pu lse mo de and select one of four Pulse Times - 1, 3, 5 or 10 minutes. NOTE: The pulse tim es are 1, 3, 5 or 10 minutes. The pul se times indicate the time between each low pulse . For example, i f 5 minutes is selected, all the a ...

  • Invacare MA80 - page 16

    SECTION 2—OPERATION MA80 Series 16 Part No 1148138 Static B utton 1. Press the Static button ( ) to select the static mode and maintain the mattress at constant pressure. NOTE: The Static LED is illumin ated GREEN. Firm/Soft Buttons 1. Select comfort pressure sett in gs by pressing Firm ( ) or Soft ( ) b uttons. • Soft Button - Pressing this bu ...

  • Invacare MA80 - page 17

    SECTION 2—OPERATION Part No 1148138 17 MA80 Se rie s 5. P erform one of the following: • Cancel - Press the Fowler button to exit Fowler T ransmitter Setup wi thout linking to a transmitter . • Sav e - W ait 60 seconds w ithout pressing a key . Max Inflate B utton 1. Press the Max Inflate button ( ) to select the max i nflate mode and inflate ...

  • Invacare MA80 - page 18

    SECTION 2—OPERATION MA80 Series 18 Part No 1148138 Powering Up the System NOTE: For this pr ocedure, r efer to FIGURE 2.5 on page 14. 1. T urn on the powe r to the system by pressing the P ow er button on the contro l uni t. NOTE: Once the button is released, a GREEN LED illuminates when the un it is on. Placing the Patient on the Ma ttress 1. Pr ...

  • Invacare MA80 - page 19

    SECTION 2—OPERATION Part No 1148138 19 MA80 Se rie s Transferring Patient From/To a Gurney  WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the gurney before transferring the patient between the bed and the gurney. 1. Engage the wheel locks of the bed. Refer to the owner ’ s manual provided w ith the bed. 2. Engage th ...

  • Invacare MA80 - page 20

    SECTION 2—OPERATION MA80 Series 20 Part No 1148138 FIGURE 2.6 Preparing for CPR Procedure Connector Cover Contro l Unit Connector Holes Hose Connector DETAIL “A” Control Unit DETAIL “B” ...

  • Invacare MA80 - page 21

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 21 MA80 Se rie s SECTION 3—MAIN TENANCE AND TROUBLESHOOTING Cleaning the System  WARNING Before cleaning or disassembling the MA80 series, check the underside of the mattress folds for sharp objects such as scissors, needles, etc. These objects should be removed and discarded before p ...

  • Invacare MA80 - page 22

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING MA80 Series 22 Part No 1148138 CAUT ION Laundry workers should always wash their hands before working with clean bedding. DO NOT overload the machine. DO NOT use chlorine bleach because it may damage the fabric coating. High air temperatures will damage the fabrics and void the Invacare warranty. i. Place ...

  • Invacare MA80 - page 23

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 23 MA80 Se rie s Changing the Filter NOTE: For this pr ocedure, r efer to FIGURE 3.1. Clean the filter ev ery 5 months or whenev er it is di rty . 1. Remov e the two screws s ecuring the filter cover to the back of the contro l unit. 2. Remov e the filter . 3. W ash the filter with water a ...

  • Invacare MA80 - page 24

    LIMITED WARRANTY PLEASE NO TE: TH E WAR RANTY B ELOW H AS BEEN DRAFTE D TO COMPLY W ITH FED ERAL LAW APPLICAB LE TO PR ODUC TS MANUFAC TURED AFTER JULY 4, 1975. This wa rrant y is e xtended o nly t o the or igin al pu rchaser who pur chases t his prod uct when new and unused from I nvacar e or a dealer. This warra nty i s not ext ended t o any o th ...

Manufacturer Invacare Category Camping Equipment

Documents that we receive from a manufacturer of a Invacare MA80 can be divided into several groups. They are, among others:
- Invacare technical drawings
- MA80 manuals
- Invacare product data sheets
- information booklets
- or energy labels Invacare MA80
All of them are important, but the most important information from the point of view of use of the device are in the user manual Invacare MA80.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Invacare MA80, service manual, brief instructions and user manuals Invacare MA80. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Invacare MA80.

Similar manuals

A complete manual for the device Invacare MA80, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Invacare MA80 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Invacare MA80.

A complete Invacare manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Invacare MA80 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Invacare MA80, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Invacare MA80, that we can find in the current document
3. Tips how to use the basic functions of the device Invacare MA80 - which should help us in our first steps of using Invacare MA80
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Invacare MA80
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Invacare MA80 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Invacare MA80?

Use the form below

If you did not solve your problem by using a manual Invacare MA80, ask a question using the form below. If a user had a similar problem with Invacare MA80 it is likely that he will want to share the way to solve it.

Copy the text from the picture