    Starck 10101XX1 10140XX1 Starck 10106XX1 10145XX1 Starck X 10170001 10175001 10180001 10185001 Installation Instructions / W arranty ...

  • Axor Starck 10101XX1 - page 2

    2 Starck 10101XX1/10106XX1 Starck 10140XX1/10145XX1 Starck X 10170001/10175001 Starck X 10180001/10185001 ...

  • Axor Starck 10101XX1 - page 3

    3 Starck 10101XX1/10106XX1/10140XX1/10145XX1 Starck X 10170001/10175001/10180001/10185001 T echnical Information Recommended water pressure 15 - 58 psi Max. water pressure 58 psi Max. hot water temp. 176°F* Recommended hot water temp. 120°F - 140°F* Max. flow rate 1.5 gpm Batter y CR-P2 / 6 V Lithium Automatic shutoff after 1 minute** *Please kn ...

  • Axor Starck 10101XX1 - page 4

    4 Do not bend or twist the supply hose! Inst allation notes Flush the hot and cold supplies thoroughly before installing the faucet. Damage to the faucet caused by debris is not covered under the warranty . The hot and cold supplies should be of equal pressure. The faucet should not be used with a con- tinuous flow water heater . Do not install the ...

  • Axor Starck 10101XX1 - page 5

    5 Installation Position the faucet on the sink or countertop (1). Install and tighten the mounting nut (2). T ighten the tensioning screws (3). Connect the 3/8” adapters to the stops (4). Connect the hoses to the adapters (5). T ighten the hoses with two wrenches, as shown, to prevent the hoses from twisting. ...

  • Axor Starck 10101XX1 - page 6

    6 Connect the faucet power cable to the batter y pack or AC power pack (1). Plug the AC power pack in. T ur n the hot and cold supplies on (2). Remove the protective film from the sensor window (3). W ait 30 seconds before attempting to use the faucet (4). Position your hand in front of the sensor to turn the water on. Due to air in the faucet, the ...

  • Axor Starck 10101XX1 - page 7

    7 Remove the faucet body (1). T ur n the temperature screw for ward to make the water cooler , backward to make it warmer (2). Dr y any drops of water from the faucet or mounting surface. Replace the faucet body (1). Replace the screw (2). T ur n the water supplies on (3). Reconnect the power cable (4). W ait 30 seconds (1). Place your hand in fron ...

  • Axor Starck 10101XX1 - page 8

    8 Battery Replacement -- models 10101XX1/ 10106XX1/10170001/10175001 only If the LED in the sensor window flashes, the batter y is low , but the faucet can still be used. If the LED lights continuously , the batter y must be changed before the faucet can be used. Remove the four screws and the batter y pack cover . Remove the old batter y (1). Inst ...

  • Axor Starck 10101XX1 - page 9

    9 Clean the aerator and filters -- all models If the water flow is reduced over time, clean the aerator (a) and the filters (b). T ur n the water supplies off (1). Disconnect the power cable (2). Starck 10101/10106/10140/10145 -- unscrew and remove the aerator (a). Starck X 10170/10175/10180/10185 -- remove the spray former (a), using a 2 mm Allen ...

  • Axor Starck 10101XX1 - page 10

    10 T ur n the water on (1). Reconnect the power cable (2). W ait 30 seconds (1). Place a hand in front of the sensor to turn the faucet on (2). ...

  • Axor Starck 10101XX1 - page 11

    11 Cleaning The faucet may be turned off temporarily so that the sink may be cleaned. Cover the sensor window with a hand for approximately 10 seconds. The faucet will turn off for approximately 60 seconds, so that the sink may be cleaned. The LED in the sensor window will flash. When the LED no longer flashes, the faucet may be used normally . ...

  • Axor Starck 10101XX1 - page 12

    12 Change the Spray Former -- Starck X 10170 / 10175 / 10180 / 10185 only The waterfall spray for mer is installed on the faucet at the fac- tor y . A round monospray spray former is included with the faucet. The spray former may be changed easily , if desired. Use a 2 mm Allen wrench to remove the spray former screws. Remove the old spray former . ...

  • Axor Starck 10101XX1 - page 13

    13 Reduce the Sensor Range The sensor is set for maximum range at the factor y . If the faucet is used on a ver y small or highly reflective lavator y , the sensor range may be reduced by ap- proximately 2”. Disconnect the power cable for approximately 10 seconds (1). Reconnect the power cable (2). The LED will blink once to indicate that it is i ...

  • Axor Starck 10101XX1 - page 14

    14 Replacement Parts 1 batter y , lithium CR-P2 / 6V 2 connection hose 98809000 3 spray former 98867000 4 aerator , Starck 95379XX0 5 fixing set 13961000 6 electronics, Starck 98799000 electronics, Starck X 98849000 7 AC adapter 8 batter y box 98801000 9 check valve 96456000 10 aerator , Starck X 95377000 XX = color 00 = chrome 80 = Steel Maintenan ...

  • Axor Starck 10101XX1 - page 15

    15 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY ...

  • Axor Starck 10101XX1 - page 16

    Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770 360-9880 • Fax 770 360 9887 www .hansgr ohe-USA.com US - Installation Instructions • Part No. 90423023 • Revised 05/2009 including, without limitation, a commercial purpose, this warranty extends only (i) for 1 year , with respect to Hansgrohe and Commercial p ...

Manufacturer Axor Category Indoor Furnishings

Documents that we receive from a manufacturer of a Axor Starck 10101XX1 can be divided into several groups. They are, among others:
- Axor technical drawings
- Starck 10101XX1 manuals
- Axor product data sheets
- information booklets
- or energy labels Axor Starck 10101XX1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Axor Starck 10101XX1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Axor Starck 10101XX1, service manual, brief instructions and user manuals Axor Starck 10101XX1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Axor Starck 10101XX1.

Similar manuals

A complete manual for the device Axor Starck 10101XX1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Axor Starck 10101XX1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Axor Starck 10101XX1.

A complete Axor manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Axor Starck 10101XX1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Axor Starck 10101XX1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Axor Starck 10101XX1, that we can find in the current document
3. Tips how to use the basic functions of the device Axor Starck 10101XX1 - which should help us in our first steps of using Axor Starck 10101XX1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Axor Starck 10101XX1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Axor Starck 10101XX1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Axor Starck 10101XX1?

Use the form below

If you did not solve your problem by using a manual Axor Starck 10101XX1, ask a question using the form below. If a user had a similar problem with Axor Starck 10101XX1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)