  • Goodman AEPT - page 1

    C US ® Made in the USA by: Goodman Manufacturing Compan y , L. P. IO-230F 2550 North Loop West, Suite 400 - Houston, Texas 77092 08/04 ww w .goodmanmfg.com or ww w .amana-hac.com © 2003-2004 Goodman Manufacturing Compan y , L. P. INS TALLATION & OPER ATING INSTRUCTIONS FOR ARU F , ARP F , ARPT and AEPT SERIES AIR HANDLER ...

  • Goodman AEPT - page 2

    2 IO-230F 08/04 INDEX INTRODUCTION .................................................................... 2 REPLACEMENT P AR TS ........................................................ 2 SAFETY INSTRUCTIONS ...................................................... 2 W ARNINGS ............................................................................ 2 ...

  • Goodman AEPT - page 3

    3 IO-230F 08/04 WARNING THIS PRODUCT IS F ACT OR Y SHIPPED FOR USE W ITH A 208-230/1/60 ELECTRICAL PO WER SUPPL Y . THIS AIR HANDLER MUST NOT BE RECONFIGURED T O OPERA TE W ITH ANY OTHER PO WER SUPPL Y . WARNING WHEN INST ALLING OR SER VICING THIS EQUIPMENT , SAFETY CLOTHING , INCLUDING HAND AND EYE PROTECTION, IS STRONGL Y ADVISED. IF INST ALLING ...

  • Goodman AEPT - page 4

    4 IO-230F 08/04 When matched with a Goodman or Amana brand condenser or heat pump, an ARI certified rating is available for many combinations. The AEPT models are equipped with an ECM TM moto r . An ECM TM motor is more efficient than a standard PSC motor and offers features such as soft-start, controlled off-delays, and constant CFM. Additional fe ...

  • Goodman AEPT - page 5

    5 IO-230F 08/04 maximum heat and allow the system to reach steady state conditions. Insert two thermometers, one in the return air and one in the supply air. The temperature rise is the supply air temperature minus the room air temperature. Use HKR specification sheets to determine the HKR available for a given air handle r. HKR INST ALLA TION Foll ...

  • Goodman AEPT - page 6

    6 IO-230F 08/04 Wire Sizing W ire size is important to the operation of your equipment. Use the following check list when selecting the appropriate wire size for your unit. • Wire size must carry the Minimum Circuit Ampacity (MCA). Refer to the NEC (USA) or CSA (Canada) for wire sizing. The unit MC A for the air handler and the optional electric ...

  • Goodman AEPT - page 7

    7 IO-230F 08/04 Piping Size For the correct tubing size, follow the specification for the condenser/heat pump. WARNING THIS COIL IS SHIPPED UNDER PRESSURE. FOLLOW THESE INSTRUCTIONS T O PREVENT INJUR Y (SEE FIGURES 1 AND 2). Evaporator Coil Metering Devices Flowrater Models (ARUF and ARPF) For most installations no change to the flowrater orifice i ...

  • Goodman AEPT - page 8

    8 IO-230F 08/04 To increase the superheat (measured at the condenser base valve), turn the stem clockwise (in). Similarl y , to decrease the superheat, turn the stem counterclockwise (out). Use a ¼ “ refrigeration wrench for this function. Note: Design point for the system is 10 degrees of superheat (measured at the condenser base valve) at 95 d ...

  • Goodman AEPT - page 9

    9 IO-230F 08/04 To complete the conversion, slide the evaporator coil into t he chass i s and a tt ach t he t h r ee ( 3 ) access pane l s . (Figure 7). CONVERSION TO HORIZONT AL The “B” series product is not suitable for horizontal application and must not be used for this type of installation. The following describes converting to “Horizont ...

  • Goodman AEPT - page 10

    10 IO-230F 08/04 IMPOR T ANT NOTE: THE EV APORA T OR COIL IS COA TED WITH OILS THA T MA Y DISSOL VE STYROFOAM AND CER T AIN TYPES OF PLASTICS. THEREFORE, A REMOV AL PUMP OR FLOA T SWITCH MUST NOT CONT AIN ANY OF THESE MA TERIALS. Tip : Priming the “P” trap may avoid improper draining at the initial installation and at the beginning of the cooli ...

  • Goodman AEPT - page 11

    11 IO-230F 08/04 Humidity Control When using a Humidistat (normally closed), cut jumper PJ6 on the control board. The Humidistat will only affect cooling airflow by adjusting the Airflow to 85%. Two Stage Heating When using staged electric heat, cut jumper PJ4 on the control board. Thermostat Wiring Use thermostat wiring diagram Figures 10 thru 13 ...

  • Goodman AEPT - page 12

    12 IO-230F 08/04 C W2 O Y R YO C G R E W2 TYPICAL H/P ROOM THERMOSTAT HEAT PUMP AR/ARUF/ARPF/ARPT 18-60 10 KW & BELOW (OPTIONAL) OUTDOOR THERMOSTAT CLOSE ON TEMPERATURE FALL RED GREEN WHITE BLUE AR UNIT R Y O W BL #18 GA. 5 WIRE #18 GA. 7 WIRE SEE NOTE #3 R G BR W BL R E D Y E L L O W O R A N G E W H I T E B L U E #18 GA. 6 WIRE NEEDED WHEN OT ...

  • Goodman AEPT - page 13

    13 IO-230F 08/04 Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficienc y . We have designed these units to significantly reduce the most frequent causes of product failure. They are simple to service and forgiving to operate. We use quality materials and c ...

Manufacturer Goodman Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman AEPT can be divided into several groups. They are, among others:
- Goodman technical drawings
- AEPT manuals
- Goodman product data sheets
- information booklets
- or energy labels Goodman AEPT
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman AEPT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman AEPT, service manual, brief instructions and user manuals Goodman AEPT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman AEPT.

Similar manuals

A complete manual for the device Goodman AEPT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman AEPT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman AEPT.

A complete Goodman manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman AEPT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman AEPT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman AEPT, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman AEPT - which should help us in our first steps of using Goodman AEPT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman AEPT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman AEPT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman AEPT?

Use the form below

If you did not solve your problem by using a manual Goodman AEPT, ask a question using the form below. If a user had a similar problem with Goodman AEPT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)