    D A TEL, Inc., Mansfield, MA 02048 (USA) · T el: (508)339-3000, (800)233-2765 F ax: (508)339-6356 · Email: sales@datel.com · Inter net: www.datel.com –V IN (1) +V IN (3) OPTO ISOLA TION PWM CONTROLLER REFERENCE & ERROR AMP INPUT UNDER VOL T AGE, INPUT O VER VOL T AGE, AND OUTPUT O VER VOL T AGE COMP ARA T ORS * Can be ordered with positiv ...

  • Datel 20A - page 2

    USQ Series USQ-1.2/20-D48 1.2 20 25 50 ±0.05% ±0.05% 48 36-75 0.63/0.87 80% C33, P32 USQ-1.5/20-D48 1.5 20 40 65 ±0.05% ±0.05% 48 36-75 0.75/1.03 85% C33, P32 USQ-1.8/20-D48 1.8 20 50 80 ±0.05% ±0.05% 48 36-75 0.88/1.23 85% C33, P32 USQ-2.5/20-D48 2.5 20 60 75 ±0.05% ±0.05% 48 36-75 1.18/1.62 87% C33, P32 USQ-3.3/20-D48 3.3 20 70 85 ±0.05% ...

  • Datel 20A - page 3

    USQ Models Remote On/Off Control P olarity: Add "P" for positiv e polarity (pin 2 open = conv er ter on) Add "N" for negativ e polarity (pin 2 open = conv er ter off) P erformance/Functional Specifications T ypical @ T A = +25°C under nominal line voltage and full-load conditions , unless noted. (1) Input Input V oltage Range: ...

  • Datel 20A - page 4

    USQ Series 4 Remov al of Soldered USQ's from PCB's Should remov al of the USQ from its soldered connection be needed, it is very impor tant to thoroughly de-solder the pins using solder wic ks or de-soldering tools. At no time should an y prying or lev erage be used to remov e boards that hav e not been properly de-soldered first. Input ...

  • Datel 20A - page 5

    USQ Models 5 On/Off Control The primar y-side, Remote On/Off Control function (pin 2) can be specified to operate with either positiv e or negative polarity . P ositive-polarity devices ("P" suffix) are enabled when pin 2 is left open or is pulled high (+2.5-5V applied with respect to –Input, pin 1, I IN < 150µA typical). Positiv ...

  • Datel 20A - page 6

    USQ Series LOAD R TRIM DOWN +OUTPUT –INPUT +INPUT ON/OFF CONTROL TRIM +SENSE –OUTPUT –SENSE 4 5 1 3 6 8 7 2 LOAD R TRIM UP +OUTPUT –INPUT +INPUT ON/OFF CONTROL TRIM +SENSE –OUTPUT –SENSE 4 5 1 3 6 8 7 2 Figure 5. T rim Connections T o Increase Output V oltages Using Fixed Resistors Figure 6. T rim Connections T o Decrease Output V oltag ...

  • Datel 20A - page 7

    USQ Models 7 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 6 1 x 10 5 1 x 10 4 1 x 10 3 Figure 7. USQ-1.2 T rim-Up Resistance vs. % Increase V OUT 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 7 1 x 10 6 1 x 10 5 1 x 10 3 1 x 10 4 Figure 8. USQ-1.5 T rim-Up Resistance vs. % Increase V OUT 0 1 2 3 4 5 6 7 8 9 10 V OUT I ...

  • Datel 20A - page 8

    USQ Series 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 8 1 x 10 7 1 x 10 6 1 x 10 5 Figure 13. USQ-12 T rim-Up Resistance vs. % Increase V OUT 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 8 1 x 10 7 1 x 10 6 1 x 10 5 Figure 14. USQ-15 T rim-Up Resistance vs. % Increase V OUT 0 2 4 6 8 10 12 14 16 18 20 V OUT DECREAS ...

  • Datel 20A - page 9

    USQ Models LOAD +OUTPUT –INPUT Sense Current Contact and PCB resistance losses due to IR drops Contact and PCB resistance losses due to IR drops Sense Retur n +INPUT ON/OFF CONTROL TRIM +SENSE –OUTPUT –SENSE 4 5 1 3 6 8 I OUT Return I OUT 7 2 Remote Sense Note: The Sense and V OUT lines are not inter nally connected to each other . Therefore ...

  • Datel 20A - page 10

    USQ Series Load Conditions ➀ Performance Specifications 1.2V OUT 1.5V OUT 1.8V OUT 2.5V OUT 3.3V OUT 5V OUT 12 to 24V OUT Load Step = 50 to 75% of I OUT Max.: P eak Deviation, typ . 115mV 110mV 125mV 100mV 170mV 125mV 100mV Settling Time to ±1% of Final V alue, max. ➁ 200µs 200µs 225µs 200µs 100µs 100µs 100µs C OUT = 10µF || 1µF Load ...

  • Datel 20A - page 11

    USQ Models T ypical P erformance Curves f or 1.2V OUT Models 90 85 80 75 70 65 60 USQ-1.2/20-D48 Efficiency vs. Line V oltage and Load Current 2 4 6 8 10 12 14 16 18 20 Load Current (Amps ) Efficiency ( % ) V IN = 36V V IN = 48V V IN = 75V Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/ ...

  • Datel 20A - page 12

    USQ Series T ypical P erformance Curves f or 1.5V OUT Models      ? ...

  • Datel 20A - page 13

    USQ Models T ypical P erformance Curves f or 1.8V OUT Models                     ...

  • Datel 20A - page 14

    USQ Series T ypical P erformance Curves f or 2.5V OUT Models Start-Up from V IN (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 1V/div 20V/div 2.5V OUT (pin 8) +Input (pin 3) Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 1V/div 2V/div 2.5V OUT (pin 8) ...

  • Datel 20A - page 15

    USQ Models T ypical P erformance Curves f or 3.3V OUT Models      ? ...

  • Datel 20A - page 16

    USQ Series T ypical P erformance Curves f or 5V OUT Models Start-Up from V IN (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 1V/div 20V/div 5V OUT (pin 8) +Input (pin 3)    ...

  • Datel 20A - page 17

    USQ Models T ypical P erformance Curves f or 5V OUT Models     ? ...

  • Datel 20A - page 18

    USQ Series T ypical P erformance Curves f or 12V OUT Models Start-Up from V IN (V IN = 48V , I OUT = 8.3A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 5V/div 20V/div 12V OUT (pin 8) +Input (pin 3) 95 90 85 80 75 70 65 60 55 USQ-12/8.3-D48 Efficiency vs. Line V oltage and Load Current 0.83 1.66 2.49 3.32 4.15 4.98 5.81 6.64 7.47 8.3 Load Curr ...

  • Datel 20A - page 19

    USQ Models Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 8.3A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 5V/div 2V/div 12V OUT (pin 8) Remote On/Off Control (pin 2) USQ-12/8.3-D24: Output Current vs. Ambient T emperature (T ransverse air flow , pin 1 to pin 3; V IN = 24V , 1/2" heat sink.) Output Current (Amps) Ambient Tem ...

  • Datel 20A - page 20

    USQ Series T ypical P erformance Curves f or 15V OUT Models 20                   ? ...

  • Datel 20A - page 21

    USQ Models 21 T ypical P erformance Curves f or 24V OUT Models Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 4.2A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 10V/div 2V/div 24V OUT (pin 8) Remote On/Off Control (pin 2) Start-Up from V IN (V IN = 48V , I OUT = 4.2A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 10V/div 20V/d ...

  • Datel 20A - page 22

    DS-0493D 10/04 BO TT OM VIEW –Input Remote On/Off +Input +Output +Sense Output T rim –Sense –Output Figure 20. Industry Standard Quarter-Brick Pinout Figure 20 readily allows users to confirm that DA TEL quar ter-brick DC/DC conv er ters are compatib le to the industry-standard pinout, independent of pin-numbering conv entions. The typical d ...

Manufacturer Datel Category Welding System

Documents that we receive from a manufacturer of a Datel 20A can be divided into several groups. They are, among others:
- Datel technical drawings
- 20A manuals
- Datel product data sheets
- information booklets
- or energy labels Datel 20A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Datel 20A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Datel 20A, service manual, brief instructions and user manuals Datel 20A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Datel 20A.

A complete manual for the device Datel 20A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Datel 20A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Datel 20A.

A complete Datel manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Datel 20A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Datel 20A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Datel 20A, that we can find in the current document
3. Tips how to use the basic functions of the device Datel 20A - which should help us in our first steps of using Datel 20A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Datel 20A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Datel 20A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Datel 20A?

Use the form below

If you did not solve your problem by using a manual Datel 20A, ask a question using the form below. If a user had a similar problem with Datel 20A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)