  • Gossen BD 232 - page 1

    Operating In structions 3-348-636-02 6/5.04 SI 232-II, BD 232 Interface Adapter with METRA win 10 / METRA Softwar e for Measuring and Recording Systems with Multimeters ...

  • Gossen BD 232 - page 2

    2 GOSSEN METRAWATT GMBH Contents Page 1 Introduction .............................................................................................................. 3 2 System Requirements .............................................................................................. 3 3 Multimeter, Adapter and METRAwin 10 Operating Modes ........... ...

  • Gossen BD 232 - page 3

    GOSSEN METRAWATT GMBH 3 1 Intro ductio n Interface Adapter Wherea s interface adapter BD232 a llows for onlin e transmission of measur ed values from multimeter to PC, memory adapter SI232/-II is a dditionally capable of saving multimeter da ta on-site without a PC. The values thus stored to memory can subsequently be transmitted to a PC. PC-Analys ...

  • Gossen BD 232 - page 4

    4 GOSSEN METRAWATT GMBH 3 Multimeter , Adapter and METRAwin 10 Operating Modes 3.1 General Information • The address for the adapter and its corr esponding multimeter must be identical. • The baud rates for the adapter and th e multimeter must also be the same. • The multimeter’ s sampl ing rate should be faster than the speed at which data ...

  • Gossen BD 232 - page 5

    GOSSEN METRAWATT GMBH 5 3.4 Configuring Multimeter Parameters – for all METRA Hit 2x with SI232-II or BD232 3.5 Receiving Live Measurement Data from the DMM – via adapter , but without savi ng to memory in the adapter SI and BD adapters can be mixed when using any METRA Hi t 2x. However , only SI adapters may be utilized if METRA Hit 1x/2x are ...

  • Gossen BD 232 - page 6

    6 GOSSEN METRAWATT GMBH 3.6 Saving Measurement Data to the SI232/-II Memor y Adapter The memory adapter can be used with all multimete r versions. Exception: Power and mains disturbance measuremen ts (V AC + dropouts + peaks) with the 29Smultimeter can on ly be saved to internal multime ter memory . Note: It is advisable to synchronize the clocks a ...

  • Gossen BD 232 - page 7

    GOSSEN METRAWATT GMBH 7 4 Adapter Connection and Initial Start-Up 4.1 Connecting the Adapter The screw connections between the stacked adapters serve exclusively to secure the connections at the serial inter face plug connectors. Disconnect each individual adapter prior to transport in order to prevent them fr om being damaged. ➭ Connect the 9-pi ...

  • Gossen BD 232 - page 8

    8 GOSSEN METRAWATT GMBH ➭ After selecting the “File/Measur e” menu it em, the r ecorded me asurement values ar e transmitted to the PC and ar e displayed at the monitor in accord ance with the display mode selected i n the “Set” menu. 4.3 Initial Start-Up – BD232 Interface Adapter ➭ Set the multimeter to the data transmission mode bef ...

  • Gossen BD 232 - page 9

    GOSSEN METRAWATT GMBH 9 5 Operating Elements, Switching the Adapter ON and OFF , Replacing the Batteries 5.1 Keypad, Interface Figure 4.2 Memory Adapter Operating E lements 1L C D Displays the respective menu item during manual operation of the memory adapter. 2 Connection between two adapters with fastening screws 3 RS232 Interface The RS232 data ...

  • Gossen BD 232 - page 10

    10 GOSSEN METRAWATT GMBH 5.2 Display Figure 4.3 Memory Adapter LCD 1 Digita l Display The current menu item appears at the 7 segm ent liquid crystal display during manual operation of the memory adapter . When stored data are viewed, measur ement valu es appear at the display in digital forma t (menu item “r eCAll”, chapter •, page 21). 2 Ana ...

  • Gossen BD 232 - page 11

    GOSSEN METRAWATT GMBH 11 5.3 Switching the Memor y Adapter ON and OFF Briefly press the right-hand ON/OFF key in order to switch the memory adapter ON . The analog scale appea rs at the LCD along wi th a display of remaining m emory capacit y , above which the last selected operating status is displaye d at the left-hand side. The memory adapter is ...

  • Gossen BD 232 - page 12

    12 GOSSEN METRAWATT GMBH 6 Operating Instructions at a Glance The memory adapter can be oper ated with the keypad on the device, or mor e conveniently with METRAwin 10 software. The most important functions from the operating menu can also be selected with h ot-keys (shortcut fun ction). 6.1 Menu Driven Operation • The key acknowl edges a menu it ...

  • Gossen BD 232 - page 13

    GOSSEN METRAWATT GMBH 13 6.3 Shortcuts at the Multimeter • Select Normal Operation – Switch the device of f, and then back on. – Or , if the device is in the measuring m ode : press the FUNC and ON keys simultaneously . – Or , if a selection menu is open: select STORE - STOP and acknowledge with ON. – Or , if the device is in the SEND mod ...

  • Gossen BD 232 - page 14

    14 GOSSEN METRAWATT GMBH 6.4 Menus Overview Te s t 4 mm:ss hh:mm dd mm:ss hh:mm dd mm:ss hh:mm dd mm:ss YES no 38400 no ModEM nnnnn Hi rAtE HYSt triG CYCLE tIME Addr bd-ou SEt durA Sample Rate p. 15 Hysteresis p. 15 Tr i g g e r p. 16 T ype of Recording p. 18 internal Time p. 18 Adapter Address p. 18 T ransmission Speed p. 19 Recording Duration p. ...

  • Gossen BD 232 - page 15

    GOSSEN METRAWATT GMBH 15 7 Menu Item Descriptions 7.1 Set Sampling Rate – rAtE Key Sequence: SEt rAtE m:ss.hh Settings: m = minutes, ss = seconds, hh = hundr edths of a second The sampling rate determines the time resolu tion of the data recorded to the memory adapter . The special interval -:--.-- is used to save only one measurement value after ...

  • Gossen BD 232 - page 16

    16 GOSSEN METRAWATT GMBH 7.3 T rigger Settings – triG The trigger setting determines which multimeter measur ement values will be stored to the adapter . Beyond this, storage to memo ry can be started by means of various trigger types (st-ou, st-in, out, in). A trigge r event occurs when high level is exceeded, or if low l evel is fallen short of ...

  • Gossen BD 232 - page 17

    GOSSEN METRAWATT GMBH 17 • Disabling the T rigger Key Sequence: SEt ... ... trIG oFF tiME oFF Settings: triG = oFF , the trigger is disabled • Enabling the T rigger - Select Level (HI, LO) and T ype (out, in, st-ou, st-in) Key Sequence: SEt ... ... trIG OFF out HI nnnnn LO nnnn n PrEtr on oFF rEtri on oFF tiME oFF Settings: nnnn n = upper / low ...

  • Gossen BD 232 - page 18

    18 GOSSEN METRAWATT GMBH 7.4 Recording: Duration and T ype – durA, CYCLE • Recording without Time Limits – durA Key Sequence: SEt ... ... durA on oFF Settings: oFF = time limiting disabled Recording is continued un til the memory is fu ll. If the CYCLE functi on has been activated, memory is overwritten in a cy clical fashion. See also drawin ...

  • Gossen BD 232 - page 19

    GOSSEN METRAWATT GMBH 19 7.7 Set T ransmission Speed – bAud-ou, bAud-in • Set T ransmission Speed to the PC – bAud-ou Key Sequence: SEt ... ... bAud-ou 19200 Settings: 9600 (default setting), 19,200 or 38,400 baud This parameter sets the speed of data tran smission between the memory adapter and the PC. The same baud rate mu st be sel ected i ...

  • Gossen BD 232 - page 20

    20 GOSSEN METRAWATT GMBH Start manual data recording: Shortcut: Press and hold the yellow ESC ke y and press the key once for each desired measurement. – Or, use the StorE menu (with assignment of a name to the memory block): Key Sequence: SEt StorE LAbEL no YES mybloc ESC Settings: mybloc = name of t he cu rrent memory block (optional) Start rec ...

  • Gossen BD 232 - page 21

    GOSSEN METRAWATT GMBH 21 • View Individual, Recorded Measurement Values Key Sequence: rECAll bbbb StAt SEE (bEGin) ... nnnnn 1 ... nnnnn m ... (End) dd hh:mm mm:ss Settings: bbbb = block numb er for stored data bEGin = flag for beginning of recording within the memory block End = flag for end of record ing within the memory block nnnnn 1... m = i ...

  • Gossen BD 232 - page 22

    22 GOSSEN METRAWATT GMBH 7.10 Reading Out Data from the Adapter at the PC / Parameter Configurations – PC Key Sequence: PC PC-nn Settings: nn = selected memory a dapter address With this bidirectional operating mode, memory adapter parameters can be configured at the PC via the interface. Be yond this, recor ded measurement data can be uploaded t ...

  • Gossen BD 232 - page 23

    GOSSEN METRAWATT GMBH 23 Figure 4.5 LCD T est • Internal Memor y T est Key Sequence: InFO tiME tESt diSP rAM no YES buSY Settings: no = no memory test is performed YES = the memory test is started with out any additional security queries After acknowledging YES with the ENTER key , the adapter’ s internal memory is tested. T esting takes about ...

  • Gossen BD 232 - page 24

    24 GOSSEN METRAWATT GMBH 8 METRAwin 10 8.1 Installing METRAwin 10 WINDOWS version 3.1 or higher is required for installation. METRAwin 10 is installed automatically . ➭ Insert the program floppy disk into drive A or B. ➭ Open the root dir ectory for the drive in to which the disk has been inserted. ➭ Open the README file with the Wor d no teb ...

  • Gossen BD 232 - page 25

    GOSSEN METRAWATT GMBH 25 9 Memor y Adapter T echnical Data Supported Measuring Instruments METRA Hit 12S ... 16S, 16I/T , 18S, 14A, 22S/M ... 29S Operating Elements and Operation 7 segment LC D display and 4 keys. Almost all parameters can be co nfigured manually , or with a PC via the int erface. Memory 128 kB CMOS memory with battery backup. Meas ...

  • Gossen BD 232 - page 26

    26 GOSSEN METRAWATT GMBH Power Supply: 2 ea. 1.5 V mignon cells Dry cell per IEC R6 type 3006: 1100 mAh Alkaline-manganese per IE C LR6 t ype 4006: 2300 mAh Service Life With alkaline-manganese cells, switched off: 27,000 h = 3 years (without self-dischar ging) With alkaline-manganese cells, switched on: Battery T est Automatic display of the -||- ...

  • Gossen BD 232 - page 27

    GOSSEN METRAWATT GMBH 27 10 Repair and Replacement Parts Ser vice DKD Calibration Lab and Rental Instrument Service When you need service, please contact: GOSSEN METRAW A TT GMBH Service-Center Thomas-Mann-Strasse 20 90471 Nür nberg, Germany Phone +49-(0)-911 -8602-0 Fax +49-(0)-911-8602- 253 E-Mail service@gossenmetrawatt.com This address is for ...

  • Gossen BD 232 - page 28

    GOSSEN METRAWATT GMBH Thomas-Mann- Str. 16-20 90471 Nuremberg, Germany Phone +49-(0)-91 1-8602-0 Fax +49-(0)-911-8602 -669 E-Mail: info@gossenmetrawatt.com www.gossenmetrawatt.com Edited in Germany • Subject to change without n otice • A pdf ver sion is available on the In ternet ...

Manufacturer Gossen Category Network Card

Documents that we receive from a manufacturer of a Gossen BD 232 can be divided into several groups. They are, among others:
- Gossen technical drawings
- BD 232 manuals
- Gossen product data sheets
- information booklets
- or energy labels Gossen BD 232
All of them are important, but the most important information from the point of view of use of the device are in the user manual Gossen BD 232.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Gossen BD 232, service manual, brief instructions and user manuals Gossen BD 232. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Gossen BD 232.

Similar manuals

A complete manual for the device Gossen BD 232, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Gossen BD 232 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Gossen BD 232.

A complete Gossen manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Gossen BD 232 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Gossen BD 232, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Gossen BD 232, that we can find in the current document
3. Tips how to use the basic functions of the device Gossen BD 232 - which should help us in our first steps of using Gossen BD 232
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Gossen BD 232