    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E User and installer Manual Sine wave Inverter, Battery charger, Transfersystem COMPACT C 1600-12 COMPACT C 2600-24 COMPACT C 4000-48 Temperature sensor CT-35 Remote control RCC-01 Solar charge controller Cxxxx-S Remote power sharing RPS-01 AC cable cover CFC-01 IP-23 top cover C-IP23 ...

  • Studer Innotec C 4000-48 - page 2

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 2 Summary 1 G ENERAL I NFORMATION ............................................................................................................... 4 1.1 O PERATING INSTRUCTIONS ........................................................................................................................4 1. ...

  • Studer Innotec C 4000-48 - page 3

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 3 4.7.3 D ELAYED MODE OF THE T RANSFER S YSTEM ..................................................................................... 17 4.8 T HE S OLAR CHAR GE CO NTROLLE R ( OPTION ) ............................................................................................ 17 4.9 T HE M ULTIFUNCT ...

  • Studer Innotec C 4000-48 - page 4

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 4 1 General Information 1.1 Operating instructions This manual is a part of the delivery package of every COMPACT inverter-charger. It serves as guidelines for safe and efficient operation of COMPACT. The instructions are only valid for use with the following devices and options: COMPACT C 1600-12 C ...

  • Studer Innotec C 4000-48 - page 5

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 5 During operation of COMPACT, high tensions are generated at the connections and inside of t he appliance which could be deadly fatal. Work on the applian ce and on the installation should only be carried out by qualified and trained personnel. The whole installation connected with the COMPACT must ...

  • Studer Innotec C 4000-48 - page 6

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 6 2 Introduction The COMPACT is a sine wave inverter with integrated battery charger and solar charger controller with many additional functions, it has been developed to be used as stand-alone (independent of a grid-system) AC provider, or as conti nuous / break-free current supply provider. 2.1 Pr ...

  • Studer Innotec C 4000-48 - page 7

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 7 2.2.4 The solar charge controller (optional) With the built-in solar charge controller, the COMPACT is a complete solar-power-center. In a solar installation this controller ensures t hat the batteries are charged correctly. With the COMPACT, batteries can be charged with a generator and with the ...

  • Studer Innotec C 4000-48 - page 8

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 8 2.3.3 Parallel- Series Connection 3 Assembly 3.1 Place of assembly The location of the COMPACT must be chosen by the following criteria: Protection from unauthorized handling. Dry dust free room, no condensation. Never install directly over the battery and never in a cabinet together with the batt ...

  • Studer Innotec C 4000-48 - page 9

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 9 3.3.2 Protection cover for the terminals connections The protection is available as an option (Order ref. CFC-01) and avoid to do wrong hazardous connection on the terminals 230Vac. It mounted with strain relief clamps for the cable. 3.4 Connecting Plan / Front side A Battery +/- Battery cable (al ...

  • Studer Innotec C 4000-48 - page 10

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 10 G Aux. Contact Connecting terminal for Auxiliary Contact H AC Input Connecting terminal for AC-input. Located directly above this term inal is the automatic safety cut-out for this terminal. J ID Plate Identification plate with Technical d ata and Serial number K AC Output Connecting terminal for ...

  • Studer Innotec C 4000-48 - page 11

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 11 3.5.4 Connection the 230Vac Input (AC INPUT) The 230V-supply from network or from a generator must be connected to the scre w terminals AC INPUT. For this use a 3-core cable with a conductor cro ss section of 2.5mm 2 . Connections are marked as follows “N“ Neutral, “PE“ Earth, “L“ Liv ...

  • Studer Innotec C 4000-48 - page 12

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 12 OFF AC OUT AC IN Ove r T emp Over loa d ON/OFF SOLAR CHARGE Batt L ow/ High Con tact manual AUX. CONTACT 70A 150V 20W OFF 0 Contact active Progr am STANDBY CHARGER Ch a r g e r - I n v e r t e r (Pr ogram ) (Change sta t us) Lock (select) CHARGER INVE RTER RESET ALA RM TRANSF ER EQUALIZE 230V 25 ...

  • Studer Innotec C 4000-48 - page 13

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 13 4.2 Light Emitting Diodes LED Marking LED lit LED blinks 1 AC IN Voltage corresponding to self- adjusted values is at the AC IN input. Voltage, outside of the self- adjusted values is at the AC IN input. 2 CHARGER Battery Charger is working The input voltage is out value (voltage or frequency) 3 ...

  • Studer Innotec C 4000-48 - page 14

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 14 4.5 The Inverter An Inverter is built in the COMPACT, which generates a sinusoidal alternating voltage of a very high quality. With this Inverter any alternating voltage consuming device 230Vac up to the nominal power of your COMPACT can be operated. Than ks to the generous dimensioning of the CO ...

  • Studer Innotec C 4000-48 - page 15

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 15 1.9 2.3 2.50 [V/cell] 2.1 A B C D 20 60 40 70 [A] A B C D t Equaliz ation Absorption Floating Chargin g current (adjust ed) Charging time Egaliz ation tim e Absorption time Floati ng 4.6 The Battery charger 4.6.1 Cycle of charge The full automatic COMPACT Battery Charger is adjusted at the factor ...

  • Studer Innotec C 4000-48 - page 16

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 16 the OUTPUT less it’s give to the charger. Priority to the OUTPUT. When the power sharing is used the LED 200% (red) is lit to point out that’s the charge is limited. Caution: If the power use on the OUTPUT is higher than the value of the INPUT LIMIT (26) the COMP ACT limits the current, then ...

  • Studer Innotec C 4000-48 - page 17

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 17 The Transfer system is protected against overload wi th an automatic safety fuse on the AC Input side of the COMPACT. If the system has been overloaded the button/pin of the fuse will pop-out. To put the automatic safety system back in to operating you must push this pin back. Note: In the Invert ...

  • Studer Innotec C 4000-48 - page 18

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 18 4.9 The Multifunctional Contact In the COMPACT there is a built-in programmable power relay. The potential-free change-over contact (NO – NC) of this power relay is c onnected to the screw terminal AUX CONTACT. Maximum Contact load: -230Vac /16Amp-30Vdc/1A ! With the Push Button 21 „AUXILIARY ...

  • Studer Innotec C 4000-48 - page 19

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 19 Caution: No external voltage should be connected to this Input Control. 4.11 The Temperature sensor Operating voltage of lead-acid batteries change depends on the temperature. To correct the operating voltages according to the actual temperatures, a temperature sensor can be connected to the COMP ...

  • Studer Innotec C 4000-48 - page 20

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 20 5.3.2 Set the voltage and timing threshold The programming is done in accordance with the following steps: Push and hold down, the Push Button 21 (Program) and the Push Button 19 (Change status) for minimum 2 seconds simultaneously. With the Push Button 20 (select) select with of the battery leve ...

  • Studer Innotec C 4000-48 - page 21

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 21 5.4.3 Examples 5.4.3.1 Auxiliary Contac t as generator starter As per the battery capacity When in the programming of the Auxiliary Contac t, the Battery Capacity (LED 15-18) is used as a condition, then you must take note of the following requirements. If you have to start an emergency back-up s ...

  • Studer Innotec C 4000-48 - page 22

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 22 5.5.1 Diagram of the different modes 9 Show an off LED Show a blinking LED Show a lighted LED CHARGE R IN VERT ER AC OUT AC IN 1 2 7 8 9 All the functions are enabled. This is the factory setting. CHARGE R IN VERT ER AC OUT AC IN 1 2 7 8 9 The inverter is disabled. Only the transfer switch and th ...

  • Studer Innotec C 4000-48 - page 23

    STUDER INNOTEC COMPACT User manual COMPACT V4.0 E 23 8 Technical Data Tech nical data Model C 1600-1 2 C 2600-2 4 C 4000-4 8 Inverter Nominal battery voltage 12V 24V 48V Input voltage range 9.5 - 16V 19 - 32V 38 - 64V Continuous power @ 25°C 1300VA 2300VA 3500VA Power 30 min. @ 25°C 1600VA 2600VA 4000VA Maximum power load 5 sec. 3 x Pnom Maximum ...

Manufacturer Studer Innotec Category Battery Charger

Documents that we receive from a manufacturer of a Studer Innotec C 4000-48 can be divided into several groups. They are, among others:
- Studer Innotec technical drawings
- C 4000-48 manuals
- Studer Innotec product data sheets
- information booklets
- or energy labels Studer Innotec C 4000-48
All of them are important, but the most important information from the point of view of use of the device are in the user manual Studer Innotec C 4000-48.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Studer Innotec C 4000-48, service manual, brief instructions and user manuals Studer Innotec C 4000-48. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Studer Innotec C 4000-48.

A complete manual for the device Studer Innotec C 4000-48, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Studer Innotec C 4000-48 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Studer Innotec C 4000-48.

A complete Studer Innotec manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Studer Innotec C 4000-48 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Studer Innotec C 4000-48, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Studer Innotec C 4000-48, that we can find in the current document
3. Tips how to use the basic functions of the device Studer Innotec C 4000-48 - which should help us in our first steps of using Studer Innotec C 4000-48
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Studer Innotec C 4000-48
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Studer Innotec C 4000-48 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Studer Innotec C 4000-48?

Use the form below

If you did not solve your problem by using a manual Studer Innotec C 4000-48, ask a question using the form below. If a user had a similar problem with Studer Innotec C 4000-48 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)