Manual Generac 1276-1

10 pages 0.84 mb
Download

Go to site of 10

Summary
  • Generac 1276-1 - page 1

    GENERAC POWER SYSTEMS, INC. P.O. BOX 297 • WHITEWATER, WI 53190 www.generac.com Part#D5507 PLEASE NOTE: This installation guide is not a substitute for the “ Installation and Owner’ s Manual” that will be furnished with the Guardian ® Home Standby Generator or the “ Owner’ s Manual” furnished with the Guardian ® Ultra Source Portabl ...

  • Generac 1276-1 - page 2

    Install your Ready Kit at the construction stage or to pre-existing homes . . . Use your Portable Generator for emergency power now . . . . . . Later install your Standby for automatic emergency power! • 100 AMP automatic transfer switch with built-in load center • 30ft. and 2ft. pre-wired conduits • 5ft. power cord and 50 AMP plug 5FT . POWE ...

  • Generac 1276-1 - page 3

    INST ALLA TION DRA WING AUTOMA TIC TRANSFER SWITCH CONNECTED TO THE EXTERNAL CONNECTION BOX Installation Guide ...

  • Generac 1276-1 - page 4

    INTRODUCTION Thank you for purchasing this “Generator Ready” Kit for the GUARDIAN ® air -cooled 12kW and 15kW automatic generators. This kit will provide you the ability to pre-wire your home or business in anticipation of the eventual purchase of a GUARDIAN ® home standby generator . This kit will also enable the operation of the GUARDIAN ® ...

  • Generac 1276-1 - page 5

    KIT INCLUDES: 50 AMP PLUG ON 5FT . POWER CORD THE EXTERNAL CONNECTION BOX Located outside the home nearest the incoming gas service. 30’ FLEXIBLE CONDUIT Pre-wired from the automatic transfer switch with built- in emergency load center for connection to the external connection box. PRE-WIRED AUTOMA TIC TRANSFER SWITCH* AND EMERGENCY LOAD CENTER W ...

  • Generac 1276-1 - page 6

    TRANSFER TO GENERA TOR POWER SOURCE WHEN UTILITY POWER F AILS 1. Set the generator’ s 50 amp circuit breaker to its OFF (or open) position. 2. T urn OFF the utility power supply to the transfer switch using the means provided (such as a utility main line circuit breaker or supplementary 70 amp circuit breaker installed in main panel. Do not attem ...

  • Generac 1276-1 - page 7

    8. From the inside of the house, feed the end of the 30- foot conduit (INCLUDED and pre-wired from transfer switch) through the wall to outside. 9. Remove the threaded lock nut from the conduit coupling. 10. Remove the knock out in the lower right corner of the external connection box. From the rear of the connection box, feed wires & 4 pin plu ...

  • Generac 1276-1 - page 8

    NOTE: Balance must be maintained when moving circuit locations from main electrical distribution panel to emergency load center . Circuit breaker positions alternate buss bars vertically . Circuits sharing a neutral wire should either be moved together to adjacent positions in emergency load center or not moved. If you are unsure of proper procedur ...

  • Generac 1276-1 - page 9

    An added feature of the GENERAC ® Generator Ready Kit is the ability to hook up a GUARDIAN ® UL TRA SOURCE portable generator . Included in the kit is a 5 foot electrical power cord (black & red), neutral (white) and ground (green) wires. At one end are the terminal connectors. At the other end is the male connector (NEMA 14-50) which plugs i ...

  • Generac 1276-1 - page 10

    1. PLAN THE LOCA TION OF YOUR GENERA TOR. NOTE: Do not place the generator directly under a window . Select an area outside of your home nearest your incoming gas service. Determine where the generator will be placed outside of the home. Arrange for fuel piping with shut-off valve to be run to this location. Keep in mind that GENERAC ® recommends ...

Manufacturer Generac Category Portable Generator

Documents that we receive from a manufacturer of a Generac 1276-1 can be divided into several groups. They are, among others:
- Generac technical drawings
- 1276-1 manuals
- Generac product data sheets
- information booklets
- or energy labels Generac 1276-1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Generac 1276-1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Generac 1276-1, service manual, brief instructions and user manuals Generac 1276-1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Generac 1276-1.

A complete manual for the device Generac 1276-1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Generac 1276-1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Generac 1276-1.

A complete Generac manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Generac 1276-1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Generac 1276-1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Generac 1276-1, that we can find in the current document
3. Tips how to use the basic functions of the device Generac 1276-1 - which should help us in our first steps of using Generac 1276-1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Generac 1276-1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Generac 1276-1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Generac 1276-1?

Use the form below

If you did not solve your problem by using a manual Generac 1276-1, ask a question using the form below. If a user had a similar problem with Generac 1276-1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)