  • Desa CGP11 - page 1

    Save this manual for future reference. VENT -FREE PROP ANE GAS HEA TER G I D E S I N N A E S T D C E R T I I F I E A M C R A S O C I A O N ® GS A WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life. — Do not store or use gasoline or other f ...

  • Desa CGP11 - page 2

    2 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ................................................................................... 4 Unpacking ............................. ...

  • Desa CGP11 - page 3

    3 SAFETY INFORMA TION Continued ! WARNING ICON G 001 W ARNINGS Continued 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch an ...

  • Desa CGP11 - page 4

    4 PRODUCT IDENTIFICA TION PRODUCT FEA TURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. Piezo Ignition System This heater has a piezo ignitor. This system requires no ma ...

  • Desa CGP11 - page 5

    5 INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow all local codes. Continued CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have the items below: ? ...

  • Desa CGP11 - page 6

    6 2. Mark two mounting screw locations on wall (see Figure 3). INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater. Figure 3 - Mounting Screw Locations Mounting Screw Locations 10 7/8" Minimum To Maintain 8" Clearance From Wall 7 3/4" 20 1/4" Minimum To Maintain 3" Clearance From Floo ...

  • Desa CGP11 - page 7

    7 Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting screw into wall stud. 3. Tighten screw until 1/16" ...

  • Desa CGP11 - page 8

    8 Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 7). 2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots. Figure 9 - Installing Bottom Mounting Screw Figure 7 - Location Of Keyhole Slots On Back Panel Of Heater Keyhole Slots Removing Front ...

  • Desa CGP11 - page 9

    9 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heat ...

  • Desa CGP11 - page 10

    10 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Figure 11 - Gas Connection * An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See ACCESS ...

  • Desa CGP11 - page 11

    11 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see ...

  • Desa CGP11 - page 12

    12 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. Control Knob A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in ...

  • Desa CGP11 - page 13

    13 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information at the top of page 12. If you don’t smell gas, go to the next step. 5. Press in control knob. Note: You may be running this heater for the first time after hooking up to gas supply. ...

  • Desa CGP11 - page 14

    14 TO SELECT HEATING LEVEL Figure 16 - Burner Patterns 1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW or HIGH positions. IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position. LOW OFF PILOT IGN HIGH OFF PILOT IGN OFF Control Knob Burners ! WARNING ICON G 0 ...

  • Desa CGP11 - page 15

    15 Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Remove front panel (see Figure 8, page 8). 2. Follow steps 1 through 6 under LIGHTING INSTRUCTIONS, pages 12 and 13. 3. With cont ...

  • Desa CGP11 - page 16

    16 If burner flame pattern is incorrect, as shown in Figure 20 • turn heater off (see TO TURN OFF GAS TO APPLIANCE, page 15) • see TROUBLESHOOTING, pages 17 through 20 Figure 20 - Incorrect Burner Flame Pattern Figure 19 - Correct Burner Flame Pattern BURNER FLAME PATTERN Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorr ...

  • Desa CGP11 - page 17

    17 CLEANING AND MAINTENANCE ODS/PILOT AND BURNER ORIFICE • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust. TROUBLE- SHOOTING POSSIB ...

  • Desa CGP11 - page 18

    18 REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Press in control knob while turning to PILOT/ IGN position 3. Continue holding down control knob. Repeat ig- niting operation until air is removed 4. Contact local propane gas company 5. Clean ODS/pilot (see CLEANING AND MAINTENANCE, page 17) or replace ODS/pilot assembly 6. Replace ga ...

  • Desa CGP11 - page 19

    19 OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial opera- tion Heater produces a clicking/ticking noise just after burner is lit or shut off REMEDY 1. Clean burner orifice(s) (see CLEANING AND MAINTEN ...

  • Desa CGP11 - page 20

    20 If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. POSSIBLE C ...

  • Desa CGP11 - page 21

    21 B.T.U. (Variable) 5,500/11,000 Type Gas Propane Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water) Maximum 14" Minimum 11" Dimensions, Inches (H x W x D) Heater 20 1/2 x 13 1/2 x 5 Carton 25 x 16 11/16 x 7 1/2 Weight (pounds) Heater 14 Shipping 17 When gas pressure is too low • pilot will ...

  • Desa CGP11 - page 22

    22 P ARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 Master Service Center 1184 Wilson NW Walker, MI 49504 616-791 ...

  • Desa CGP11 - page 23

    23 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under REPLACEMENT PARTS on page 21 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-02 Front Panel Assembly 1 3 099318-01 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 099469 ...

  • Desa CGP11 - page 24

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED ...

Manufacturer Desa Category Gas Heater

Documents that we receive from a manufacturer of a Desa CGP11 can be divided into several groups. They are, among others:
- Desa technical drawings
- CGP11 manuals
- Desa product data sheets
- information booklets
- or energy labels Desa CGP11
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa CGP11.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa CGP11, service manual, brief instructions and user manuals Desa CGP11. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa CGP11.

Similar manuals

A complete manual for the device Desa CGP11, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa CGP11 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa CGP11.

A complete Desa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa CGP11 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa CGP11, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa CGP11, that we can find in the current document
3. Tips how to use the basic functions of the device Desa CGP11 - which should help us in our first steps of using Desa CGP11
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa CGP11
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa CGP11 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa CGP11?

Use the form below

If you did not solve your problem by using a manual Desa CGP11, ask a question using the form below. If a user had a similar problem with Desa CGP11 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)