    DYNA-GLAS TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS 5MPRA Series MODELS 5MPRA6C-146 5MPRA6C3-146 5MPRA6D-147 5MPRA6D3-147 5MPRA6E-148 5MPRA6E3-148 5MPRA6F-156 5MPRA6F3-156 STA-RITE FOREIGN SALES CORP. 175 WRIGHT STREET, DELAVAN, WISCONSIN 53115 USA Telephone: (414) 728-5551; Telefax: ...

  • Mad Catz 5MPRA6D-147 - page 2

    2 ‘5MPRA ’ SERIES PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘5MPRA’ Series Self-priming Centrifugal pump: • Is designed for use with swimming pools or as a centrifugal pump. • Is an excellent performer; durable, reliable. T able ...

  • Mad Catz 5MPRA6D-147 - page 3

    3 READ AND FOLLOW ALL INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal injury, or major property damage if ignored. warns about hazards tha ...

  • Mad Catz 5MPRA6D-147 - page 4

    4 INST ALL A TION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10'(3m). Allow use of short, di ...

  • Mad Catz 5MPRA6D-147 - page 5

    5 Piping: Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase size if a long run is needed. When using 1-1/2" pipe, connect to pump with 1-1/2" to 2" (38 to 51mm) reducing adapter. To avoid strains on the pump, support both suction and discharge pipes inde- pendently. Place these supports near the pump ...

  • Mad Catz 5MPRA6D-147 - page 6

    6 ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Ground Fault Circuit Interrupter (GFCI) tripping indica ...

  • Mad Catz 5MPRA6D-147 - page 7

    7 OPERA TION NOTICE: NEVER run pump dry. Running pump dry may damage seals, caus- ing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. If pump is being pressure tested ...

  • Mad Catz 5MPRA6D-147 - page 8

    8 Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do not cover pump with plastic. For outdoor/unprotected installations: 1. Enclose entire system in a weatherproof enclosure. 2 ...

  • Mad Catz 5MPRA6D-147 - page 9

    9 PUMP SER VICE Pump should only be serviced by qualified personnel. Be sure to prime pump (Pg. 7) before starting. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GA TE V ALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. To avoid dangerous or fatal electrical shock hazard, turn OFF powe ...

  • Mad Catz 5MPRA6D-147 - page 10

    10 Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge with small amount of liquid detergent; press ceramic seat into seal plate cavity firmly and squarely with finger pressure (Fig. 6). 2. If ceramic seat will not locate properly, remove it, place face up on bench and reclean cavity ...

  • Mad Catz 5MPRA6D-147 - page 11

    11 Clogged pipe/trap/impeller, worn impeller: 7. Make sure suction trap is not clogged; if it is, clean trap and strainer. 8. Make sure impeller is not clogged (follow steps 1 through 7 under “Removing Old Seal”, Page 9; check impeller for clogging; follow steps 7 through 11 under “Installing New Seal”, Page 10, for reassembly). 9. Impeller ...

  • Mad Catz 5MPRA6D-147 - page 12

    1 2 3 4 5 6 7 8 8A 8B Box A Box A 11 12 13 14 15B 15A 16 17 18 19 20 21 22 23 9 10 012 0394 BOX A For quick disconnect pipe connection parts: Adapter Union Pkg ..................... 11201-0153 O-Rings (2) .................... 35505- 1318 Key Part No. Description Qty. 1 Motor 115/230 Volt/1 Phase 1 Chart at right 2 Screw #10-32x1/2" 1 U30-692SS ...

Manufacturer Mad Catz Category Water Pump

Documents that we receive from a manufacturer of a Mad Catz 5MPRA6D-147 can be divided into several groups. They are, among others:
- Mad Catz technical drawings
- 5MPRA6D-147 manuals
- Mad Catz product data sheets
- information booklets
- or energy labels Mad Catz 5MPRA6D-147
All of them are important, but the most important information from the point of view of use of the device are in the user manual Mad Catz 5MPRA6D-147.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Mad Catz 5MPRA6D-147, service manual, brief instructions and user manuals Mad Catz 5MPRA6D-147. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Mad Catz 5MPRA6D-147.

A complete manual for the device Mad Catz 5MPRA6D-147, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Mad Catz 5MPRA6D-147 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Mad Catz 5MPRA6D-147.

A complete Mad Catz manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Mad Catz 5MPRA6D-147 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Mad Catz 5MPRA6D-147, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Mad Catz 5MPRA6D-147, that we can find in the current document
3. Tips how to use the basic functions of the device Mad Catz 5MPRA6D-147 - which should help us in our first steps of using Mad Catz 5MPRA6D-147
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Mad Catz 5MPRA6D-147
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Mad Catz 5MPRA6D-147 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Mad Catz 5MPRA6D-147?

Use the form below

If you did not solve your problem by using a manual Mad Catz 5MPRA6D-147, ask a question using the form below. If a user had a similar problem with Mad Catz 5MPRA6D-147 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)