Manual Cornelius CH550

12 pages 0.08 mb
Download

Go to site of 12

Summary
  • Cornelius CH550 - page 1

    Operator ’ s Manual CHILLER (“CHILLER” SERIES) Models: CH550 and CH 551 PRINTED IN U.S.A IMI CORNELIUS INC; 1999–2002  IMI CORNELIUS REMCOR INC  500 REGENCY DRIVE  GLENDALE HEIGHTS, IL 60139–2268 T elephone (800) 551–4423 Facsimile (800) 519–4423 Part No. 91272 Revised: August 9, 2002 Revision C THIS DOCUMENT CONT AINS IMPORT ...

  • Cornelius CH550 - page 2

    i 91272 T ABLE OF CONTENTS Page INTRODUCTION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICA TIONS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INST ALLA TION INSTRUCTIONS 2 . . . . . . . . . . . . ...

  • Cornelius CH550 - page 3

    1 91272 INTRODUCTION The REMCOR “ CH ” Series W ater Chillers (Models CH550 – A and CH551 – A) are specifically designed to cool clean water before it is circulated to the cooling application. The Unit includes a complete refrigeration system and associated controls housed in a sturdy sheet metal enclosure with perforated panels for air cir ...

  • Cornelius CH550 - page 4

    2 91272 INST ALLA TION INSTRUCTIONS LOCA TION Locate the chiller indoors in a well ventilated area with ambient temperatures in the range of 65 ° to 100 ° F . Allow a minimum of six inches of clearance around the chiller for proper air circulation. Avoid hot air discharge from other equipment or enclosed areas where heat could build up and cause ...

  • Cornelius CH550 - page 5

    3 91272 When the flow rate to the process is critical, a flow meter and valve should be installed in the line in order to ob- tain the proper flow rate. On Units with optional bypass valve, the aforementioned valve can be omitted and the flow can be adjusted with this valve. T urning the valve clockwise increases the flow to the process whereas tur ...

  • Cornelius CH550 - page 6

    4 91272 3. Remove the screw securing the mounting bracket to the back of the thermostat. 4. Remove the thermostat from the front panel. 5. Install the new thermostat in the front panel and secure it with the mounting bracket. 6. Reconnect the wires at back of the thermostat. 7. Install the wrapper . REPLACING ELECTRONIC DIFFERENTIAL THERMOST A T 1. ...

  • Cornelius CH550 - page 7

    5 91272 FLUID RECOMMENDA TION Remcor Chillers are designed to operate with water to provide maximum performance for temperatures of 40  F – 100  F. Distilled W ater Acceptable De – Ionized W ater (1 – 5 MEG/OHMS) Acceptable De – Ionized W ater (5+MEG/OHMS) Acceptable with Stainless Steel & PVC only *No Copper or Brass Propylene Gl ...

  • Cornelius CH550 - page 8

    6 91272 TROUBLESHOOTING GUIDE T rouble Probable Cause Remedy CHILLER DOES NOT OPERA TE A. No power . A. Check fuse or circuit breaker . B. Loose or poor wire connection. B. Check wiring. Correct for loose or poor wire connection. C. Inoperable ON – OFF switch. C. Replace ON – OFF switch. D. Overload device open. D. Allow compressor to cool, the ...

  • Cornelius CH550 - page 9

    7 620909701 P ARTS LIST FIGURE 1. CH550 AND CH551 EXPLODED VIEW Item No. Part No. Name 1 31934 Switch, Illuminated (CH550) 31935 Switch, Illuminated (CH551) 2 32386 Thermostat, Eliwell No. EWPC902 3 620603708 Blade, Fan 4 62060371 1 Motor , Fan (CH550) 620603709 Motor , Fan (CH551) 5 * Condenser 6 Not Used 7 620603701 Compressor (CH550) 620603702 C ...

  • Cornelius CH550 - page 10

    ...

  • Cornelius CH550 - page 11

    8 91272 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you. Please provide the ...

  • Cornelius CH550 - page 12

    CORPORA TE HEADQUARTERS: Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139 ...

Manufacturer Cornelius Category Refrigerator

Documents that we receive from a manufacturer of a Cornelius CH550 can be divided into several groups. They are, among others:
- Cornelius technical drawings
- CH550 manuals
- Cornelius product data sheets
- information booklets
- or energy labels Cornelius CH550
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cornelius CH550.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cornelius CH550, service manual, brief instructions and user manuals Cornelius CH550. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cornelius CH550.

Similar manuals

A complete manual for the device Cornelius CH550, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cornelius CH550 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cornelius CH550.

A complete Cornelius manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cornelius CH550 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cornelius CH550, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cornelius CH550, that we can find in the current document
3. Tips how to use the basic functions of the device Cornelius CH550 - which should help us in our first steps of using Cornelius CH550
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cornelius CH550
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cornelius CH550 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cornelius CH550?

Use the form below

If you did not solve your problem by using a manual Cornelius CH550, ask a question using the form below. If a user had a similar problem with Cornelius CH550 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)