  • Desa B200 - page 1

    POR T ABLE FORCED AIR HEA TER OWNER’S MANUAL 200,000 Btu/Hr Models: B200, R200, and REM200 ARL LOGO G 004 ® IMPORTANT Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. ...

  • Desa B200 - page 2

    2 102569 POR T ABLE FORCED AIR HEA TER 200,000 Btu/Hr • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels. • Fueling a) Personnel involved with fueling shall be qualified and thoroughly familiar with the manufacturer's instructio ...

  • Desa B200 - page 3

    3 102569 OWNER’S MANUAL 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . PRODUCT IDENTIFICA TION UNP ACKING Lower Shell Hot Air Outlet Fan Guard Fuel Tank Flame-out Control Reset Button Side Cover ...

  • Desa B200 - page 4

    4 102569 POR T ABLE FORCED AIR HEA TER 200,000 Btu/Hr FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in: • clogged fuel filter and nozzle • carbon build up on spark plug • the need of nontoxic anti-icer in fuel dur- ing very cold weather IMPORTANT: Use a KEROSENE ONLY storage container. Be ...

  • Desa B200 - page 5

    5 102569 OWNER’S MANUAL THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the ...

  • Desa B200 - page 6

    6 102569 POR T ABLE FORCED AIR HEA TER 200,000 Btu/Hr Item How Often How To Fuel tank Flush every 150-200 hours See Storing, Transporting, of operation or as needed or Shipping Air output and Replace every 500 hours of See Air Output, Air Intake, lint filters operation or once a year and Lint Filters, page 8 Air intake filter Wash and dry with so ...

  • Desa B200 - page 7

    7 102569 OWNER’S MANUAL 1. W rong pump pressure 2 . Dirty air output, air intake and lint filters 3. Dirty fuel filter 4. Dirt in nozzle 5. Dirty photocell lens 6. Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operat ...

  • Desa B200 - page 8

    8 102569 POR T ABLE FORCED AIR HEA TER 200,000 Btu/Hr SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard. FAN IMPORTANT: Remove fan from motor shaft before removing motor from heater. The ...

  • Desa B200 - page 9

    9 102569 OWNER’S MANUAL FUEL FILTER 1 . Remove side cover screws using 5/16" nut-driver . 2. Remove side cover . 3 . Pull lower fuel line off the fuel valve fitting. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5. W ash fuel filter with clean fuel and replace in tank. 6. Attach lower fuel line to fuel valve f ...

  • Desa B200 - page 10

    10 102569 POR T ABLE FORCED AIR HEA TER 200,000 Btu/Hr NOZZLE 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fan , page 8). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using ...

  • Desa B200 - page 11

    11 102569 OWNER’S MANUAL Figure 16 - Removing Nozzle Figure 17 - Rotor Location Sandpaper Figure 19 - Sanding Rotor Figure 18 - Gap Adjusting Screw Locations Nozzle Face Nozzle Seal Nozzle Burner Head Fuel Line Fitting Air Line Fitting SER VICE PROCEDURES Continued PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see Upper Shell ...

  • Desa B200 - page 12

    12 102569 POR T ABLE FORCED AIR HEA TER 200,000 Btu/Hr ILLUSTRA TED PA R T S BREAKDOWN B200, R200, REM200 Motor and Pump Assembly 7-1 7-8 Burner Head Assembly 7-7 7-3 7-4 7-5 7-6 10-16 10-17 10-15 10-18 10-14 10-13 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 22 21 30 ...

  • Desa B200 - page 13

    13 102569 OWNER’S MANUAL KEY PART NO. NUMBER DESCRIPTION QTY. 1 098511-208 Upper Shell (Yellow) 1 098511-209 Upper Shell (White) 1 098511-229 Upper Shell (Black) 1 2 100647-01 Screw, #10-16 x 1/2" 8 3 098512-48 Combustion Chamber 4 099229-01 Photocell Bracket 1 5 M10908-2 Screw, #6-32 x 3/8" 2 6 HA3019 Photocell Assembly 1 7 *** Burner ...

  • Desa B200 - page 14

    14 102569 POR T ABLE FORCED AIR HEA TER 200,000 Btu/Hr Btu/Hr 200,000 Flame-out Control Part No. HA3003 Spark Plug Part No. HA3012 Filter Kit Part No. HA3017 Nozzle Part No. 100735-13 Rotor/Air Pump Kit Part No. HA3005 Handle Part No. HA2204 Photocell Part No. HA3019 Pump Adjustment Part No. HA3020 1 2 3 4 WHEELS AND HANDLE PARTS LIST KEY PART PART ...

  • Desa B200 - page 15

    15 102569 OWNER’S MANUAL White Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow WIRING DIAGRAM Note: Use only original replacement parts. This will protect your warranty coverag ...

  • Desa B200 - page 16

    102569-01 Rev. G 08/99 INTERNA TIONAL W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will re ...

Manufacturer Desa Category Electric Heater

Documents that we receive from a manufacturer of a Desa B200 can be divided into several groups. They are, among others:
- Desa technical drawings
- B200 manuals
- Desa product data sheets
- information booklets
- or energy labels Desa B200
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa B200.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa B200, service manual, brief instructions and user manuals Desa B200. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa B200.

A complete manual for the device Desa B200, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa B200 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa B200.

A complete Desa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa B200 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa B200, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa B200, that we can find in the current document
3. Tips how to use the basic functions of the device Desa B200 - which should help us in our first steps of using Desa B200
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa B200
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa B200 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa B200?

Use the form below

If you did not solve your problem by using a manual Desa B200, ask a question using the form below. If a user had a similar problem with Desa B200 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)