    PROP ANE CONSTRUCTION HEA TER OWNER’S MANUAL GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POI- SONING, AND/OR ELECTRICAL SHOCK. ONLY PERSONS WHO C ...

  • Desa REM50PVA - page 2

    PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 2 105331 SAFETY INFORMA TION WARNING: FIRE, BURN, IN- HALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUS- TIBLES, SUCH AS BUILDING MA- TERIALS, PAPER OR CARD- BOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE IN- STRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR ...

  • Desa REM50PVA - page 3

    OWNER’S MANUAL 3 105331 PRODUCT IDENTIFICA TION Figure 1 - 50,000 BTU/Hr Model UNP ACKING 1. Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regulator assembly) for storage. 2. Remove all items from carton. 3. Check all items for shipping damage. If heater is damaged, promptly ...

  • Desa REM50PVA - page 4

    PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 4 105331 Air For Combustion Air For Heating THEOR Y OF OPERA TION Combustion Chamber THE FUEL SYSTEM The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater. THE AIR SYSTEM The motor turns the fan. The fan pushes air into and around the combustion chamber. This air ...

  • Desa REM50PVA - page 5

    OWNER’S MANUAL 5 105331 INST ALLA TION Valve Inlet Hose Figure 7 - Hose and Inlet Connector WARNING: Review and un- derstand the warnings in the Safety Information section, page 2. They are needed to safely op- erate this heater. Follow all local codes when using this heater. Propane Tank Propane Supply Valve Regulator Hose Fuel Gas Fitting Figur ...

  • Desa REM50PVA - page 6

    PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 6 105331 OFF MED HIGH ST ART/ LOW STORAGE 1. Store propane tank(s) in safe manner . See Chapter 5 of Standar d for Storage and Handling of Liquefied Petr oleum Gases, ANSI/NFP A 58. Follow all lo- cal codes. Always store propane tanks outdoors. 2. Place plastic cover caps over brass fittings on inlet co ...

  • Desa REM50PVA - page 7

    OWNER’S MANUAL 7 105331 REMEDY 1. Check voltage to electrical outlet. If volt- age is good, check heater power cord for breaks 2. Adjust motor/fan guard to keep fan from hitting inside of heater shell. Bend fan guard if necessary 3. Replace fan. See Fan, page 9 4. Replace motor . See Motor , page 8 1. Repeat installation and operation in- structi ...

  • Desa REM50PVA - page 8

    PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 8 105331 SER VICE PROCEDURES WARNING: Never service heater while it is plugged in, con- nected to propane supply, oper- ating, or hot. Severe burns and electrical shock can occur. You can also visit DESA International’s Technical Service web site at www.desatech.com. ELECTRICAL SYSTEM The entire electri ...

  • Desa REM50PVA - page 9

    OWNER’S MANUAL 9 105331 IGNITOR 1. Remove motor and fan guard from heater (see Motor , page 8, steps 1 through 5). 2. Remove black ignitor wire from piezo ignitor . Access ignitor wire through un- derside of heater base (see Figure 17). Push wire up through bushing in heater shell. 3. Remove ignitor mounting screw from rear head using nut-driver ...

  • Desa REM50PVA - page 10

    PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 10 105331 28 27 15 17 18 21 1 2 3 2 4 6 7 9 11 21 22 23 24 25 19 2 10 26 16 12 13 14 5 20 20 8 ILLUSTRA TED P ARTS BREAKDOWN RLP50VA BLP50VA REM50PVA ...

  • Desa REM50PVA - page 11

    OWNER’S MANUAL 11 105331 P AR TS LIST RLP50VA BLP50VA REM50PVA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual. KEY PART NO. NO. DESCRIPTION QTY. 1 104154-01 Combustion Chamber 1 2 M11084-26 Hex Tap Screw, #10-16 x 3/8" 7 3 105333- ...

  • Desa REM50PVA - page 12

    PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 12 105331 SPECIFICA TIONS Output Rating (BTU/Hr) High 49,500 Low 30,000 Fuel Propane Vapor Only Fuel Consumption Gallons/Hour 2.19 / 1.09 Pounds/Hour 9.28 / 4.64 Supply Pressure To Regulator Minimum (for input adjustment) 10 psi Maximum 200 psi Regulator Outlet Pressure High 18" WC Manifold Pressure ...

  • Desa REM50PVA - page 13

    OWNER’S MANUAL 13 105331 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Desa REM50PVA - page 14

    W ARRANTY AND REP AIR SER VICE LIMITED WARRANTY KEEP THIS WARRANTY For information, write: DESA International, P.O. Box 90004 Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department When writing, always include model number and serial number. 105331-01 REV. B 03/00 Model Serial No. Date of Purchase 2701 Industrial Drive P.O. Box 90004 ...

Manufacturer Desa Category Electric Heater

Documents that we receive from a manufacturer of a Desa REM50PVA can be divided into several groups. They are, among others:
- Desa technical drawings
- REM50PVA manuals
- Desa product data sheets
- information booklets
- or energy labels Desa REM50PVA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa REM50PVA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa REM50PVA, service manual, brief instructions and user manuals Desa REM50PVA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa REM50PVA.

A complete manual for the device Desa REM50PVA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa REM50PVA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa REM50PVA.

A complete Desa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa REM50PVA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa REM50PVA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa REM50PVA, that we can find in the current document
3. Tips how to use the basic functions of the device Desa REM50PVA - which should help us in our first steps of using Desa REM50PVA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa REM50PVA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa REM50PVA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa REM50PVA?

Use the form below

If you did not solve your problem by using a manual Desa REM50PVA, ask a question using the form below. If a user had a similar problem with Desa REM50PVA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)