    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 1/18 Maxeta iFA S eries DC-DC Power Modules 24V Input, 28V Output, 602W Full Brick The Maxeta  iFA series power modules are ideally suited for wireless appli cations to power RF power amplifiers. W ith a typical 89% full load ...

  • TDK iFA Series - page 2

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 2/18 Ordering i nformation: Product Identifier Package Size Platform Input Voltage Output Current/ Power Output Units Main Output Voltage # Of Outputs Safety Class Feature Set i F A 24 021 A 280 V - 0 00 TDK Innoveta Full Brick S ...

  • TDK iFA Series - page 3

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 3/18 Mechanical Specification : Unless otherwise sp ecified, tolerances are: x.x ± 0.5 m m [x.xx ± 0.02 in.], x.xx ± 0.25 m m [x.xxx ± 0.010 in.]. 1 2 3 5 6 7 8 9 10 12 4 13 14 15 16 17 Recom mended h ole pattern (top view) ...

  • TDK iFA Series - page 4

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 4/18 Pin Assignment : PIN FUNCTION PIN FUNCTION PIN FUNCTION 1 ON/OFF (+) 7 Vout (-) 13 PWR GOOD 2 ON/OFF (-) 8 Vout (+) 14 Parallel Control 3 Vin (+) 9 Vou t (+) 15 T RIM 4 Vin (-) 10 Vo ut (+) 16 SENSE (+) 5 Vout (-) 11 Not pre ...

  • TDK iFA Series - page 5

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 5/18 Absolute Maximum Ratings : Stress in excess of Absolu te Maximum Ratings may cause permanent da mage to the device. Input Characte ristics : Unless otherwise specified, specifications apply over all Rated Input Voltage, Resi ...

  • TDK iFA Series - page 6

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 6/18 Electrical Data : iFA24021 A280V- 000 t hrou gh - 026: 2 8V, 21.5 A, 602W O utput Characteristic Min Typ Max Unit Notes & Conditio ns Output Voltage Initial Set-poin t 27.30 28 28. 42 V dc Vin=Vin,nom; Io=Io,max ; Tc = 2 ...

  • TDK iFA Series - page 7

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 7/18 Electrical Characteristics: iFA24021 A280V- 000 t hrou gh - 026: 28 V, 21.5 A, 602W O utput 7 5 7 7 7 9 8 1 8 3 8 5 8 7 8 9 9 1 9 3 4 5 6 7 8 9 10 1 1 1 2 1 3 14 1 5 1 6 1 7 18 1 9 2 0 2 1 Outp u t Curre n t ( A ) E f f i c ...

  • TDK iFA Series - page 8

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 8/18 Electrical Characteristics: iFA24021 A280V- 000 throu gh - 02 6: 28V, 21. 5 A, 602W Outpu t Output Ripple at Nominal Inp ut Voltage and Full Load, Ta=25 ° C Ch. 1: Vo Ch. 4: Io Dynamic Load Response. Load s tep from 50% to ...

  • TDK iFA Series - page 9

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 9/18 Thermal Perform ance : iFA24021 A280V- 000 t hrou gh - 026: 28 V, 21.5 A, 602W O utput Maximum output current vs. a mbient temperature at nominal input voltage for airflo w rates natural convection 0.3 m/s (60lf m) to 3.0m/s ...

  • TDK iFA Series - page 10

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 10/18 Thermal Ma nagement: An im portant part of the overall s ystem design proces s is therm al m anagem ent; therm al design m ust be considere d at all levels to ens ure good r eliabilit y and lifetim e of the fina l system . ...

  • TDK iFA Series - page 11

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 11/18 Perform ance page f or the p ower m odule of interest. In all conditio ns, the p ower m odule should be op erated be low the m axim um operating tem perature s how n on the derating cur ve . For im proved des ign mar gins a ...

  • TDK iFA Series - page 12

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 12/18 Operating I nformation: Outpu t Over-Current Protect ion: T he power m odules are e quipped with current limit, over-c urrent slo w hiccup, a nd over- current trip fas t hiccup m ode protec tion. These three pr otection m e ...

  • TDK iFA Series - page 13

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 13/18 An alternat ive wa y to control ON/O FF is from the output side b y utilizing AUX output pin of the sam e m odule. To do s o, the us er must suppl y a switch b etween the m odule sense(-) terminal and the –O N/OFF term in ...

  • TDK iFA Series - page 14

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 14/18 If the output voltage adjustm ent f eature is not used, t he Vout(+) p in shou ld be short ed to the sense( +) pin an d the Vout(- ) pin should be s horted to the sense( -) pin b y jumper wires . Fi g u r e Tri m D ow n C o ...

  • TDK iFA Series - page 15

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 15/18 The output v oltage c an also be adjusted within the sam e range b y applying externa l voltage at the trim pin via a buf fer. In this case, Vo_d c an be ap proxim ately determ ined by the fol lowing form ula: Vo_d ≅ Trim ...

  • TDK iFA Series - page 16

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 16/18 Auxiliar y Bias Pow er (Optio nal): The iFA series power m odules provide an aux iliar y output, which is ref erenced to th e output sense (-) pin. It prov ides an out put volta ge between 7.5 and 13.5V dc that c an supp ly ...

  • TDK iFA Series - page 17

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 17/18 Input/Output Ripple a nd Noise Me asurements: The input reflected ripple i s measured w ith a current probe and oscilloscope. The ripple current is the curr ent through the 15uH inductor, Lin, w ith esr ≤ 10 m Ω , feed ...

  • TDK iFA Series - page 18

    Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 18/18 To pres erve max imum flexibilit y, the power modules ar e not intern ally fus ed. An external input line norm al blo w fuse with a maxim um value of 40 A is requ ired by safet y agencies. A lower va lue fuse can be selecte ...

Manufacturer TDK Category Network Card

Documents that we receive from a manufacturer of a TDK iFA Series can be divided into several groups. They are, among others:
- TDK technical drawings
- iFA Series manuals
- TDK product data sheets
- information booklets
- or energy labels TDK iFA Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual TDK iFA Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals TDK iFA Series, service manual, brief instructions and user manuals TDK iFA Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product TDK iFA Series.

A complete manual for the device TDK iFA Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use TDK iFA Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of TDK iFA Series.

A complete TDK manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual TDK iFA Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the TDK iFA Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the TDK iFA Series, that we can find in the current document
3. Tips how to use the basic functions of the device TDK iFA Series - which should help us in our first steps of using TDK iFA Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with TDK iFA Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of TDK iFA Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning TDK iFA Series?

Use the form below

If you did not solve your problem by using a manual TDK iFA Series, ask a question using the form below. If a user had a similar problem with TDK iFA Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)