    Page 1 12821-6-0406 VENTED ROOM HEA TER MODELS RH-25-6 RH-35-6 EFFECTIVE DA TE APRIL 2006 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL — Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. — WHA T TO DO IF YOU SMELL GAS • Do not try to light any appli- ance. • Do no t t o ...

  • Langley/Empire RH-35-6 - page 2

    Page 2 12821-6-0406 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ......................................................................................................4 Introduction ........... ...

  • Langley/Empire RH-35-6 - page 3

    Page 3 12821-6-0406 • Due to high temperatures, the r oom heater should be located out of traffic and away fr om furnitur e and drap- eries. • Childr en and adults should be alerted to the hazards of high surface temperatur e and should stay away to avoid burns or clothing ignition. • Y oung children should be carefully supervised when they ...

  • Langley/Empire RH-35-6 - page 4

    Page 4 12821-6-0406 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area ...

  • Langley/Empire RH-35-6 - page 5

    Page 5 12821-6-0406 Introduction Always consult your local Building Department regarding regu- lations, codes or ordinances which apply to the installation of a vented room heater . Instructions to Installer 1. Installer must leave instruction manual with owner after instal- lation. 2. Installer must have owner fill out and mail warranty card sup- ...

  • Langley/Empire RH-35-6 - page 6

    Page 6 12821-6-0406 Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code. The use of the following gas connectors is recommended: — ANS Z21.24 App lianc e Conn ...

  • Langley/Empire RH-35-6 - page 7

    Page 7 12821-6-0406 Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Right side 6 inches (152mm). Left side 6 inches (152mm). Recommend 18 inches (457mm) on left side for servicing. Do not install in alcove or closet. No horizontal projection above heater permitt ...

  • Langley/Empire RH-35-6 - page 8

    Page 8 12821-6-0406 This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. W arning: Operation of this heater , when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system, can result in carbon monoxide (CO) poisoning and po ...

  • Langley/Empire RH-35-6 - page 9

    Page 9 12821-6-0406 1. STOP! Read the safety information to the left of this label. 2. Set thermostat to lowest setting. 3. T urn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. W ait ten (10) minutes to clear out an ...

  • Langley/Empire RH-35-6 - page 10

    Page 10 12821-6-0406 The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting when the inlet pressure is ...

  • Langley/Empire RH-35-6 - page 11

    Page 1 1 12821-6-0406 T o Remove Main Burner 1. Disconnect the thermocouple and pilot supply line at the pilot burner . 2. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner . 3. Remove screw on each side of the main burner and lift out. T o Remove Main Burner Orifice 1. Unscrew the nut on the orifi ...

  • Langley/Empire RH-35-6 - page 12

    Page 12 12821-6-0406 INDEX NO. P AR T NUMBER DESCRIPTION 1 R-6096 Knob & Adaptor Set 2 1 1700 Control Rod Bracket 3 R-2706 ECO Switch 4 R-8195 ECO W ire Assembly 5 1 1699 Control Rod 6 R-6104 Gas V alve (LPG) 6 R-6103 Gas V alve (Nat) 7 1 1697 V alve Bracket 8 RH-705 Casing Side 9 RH-708 Air Inlet Baffle 10 P-86-37 Main Burner Orifice, (RH-35 ...

  • Langley/Empire RH-35-6 - page 13

    Page 13 12821-6-0406 ...

  • Langley/Empire RH-35-6 - page 14

    Page 14 12821-6-0406 DRB-1 For V ented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Dir ect V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) , remove casing front. 1. For DV -25-(1, 2)SG and DV -35-(1, 2)SG , remove casing front an ...

  • Langley/Empire RH-35-6 - page 15

    Page 15 12821-6-0406 Code, CSA C22.1 , if an external electrical source is utilized. This appliance is equipped with a three-pr ong [grounding] plug for your protection against shock hazard and should be plugged directly into a pr operly grounded three-pr ong receptacle. Do not cut or remove the grounding prong fr om this plug. For an ungrounded re ...

  • Langley/Empire RH-35-6 - page 16

    Page 16 12821-6-0406 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com SER VICE NOTES ...

Manufacturer Langley/Empire Category Electric Heater

Documents that we receive from a manufacturer of a Langley/Empire RH-35-6 can be divided into several groups. They are, among others:
- Langley/Empire technical drawings
- RH-35-6 manuals
- Langley/Empire product data sheets
- information booklets
- or energy labels Langley/Empire RH-35-6
All of them are important, but the most important information from the point of view of use of the device are in the user manual Langley/Empire RH-35-6.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Langley/Empire RH-35-6, service manual, brief instructions and user manuals Langley/Empire RH-35-6. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Langley/Empire RH-35-6.

A complete manual for the device Langley/Empire RH-35-6, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Langley/Empire RH-35-6 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Langley/Empire RH-35-6.

A complete Langley/Empire manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Langley/Empire RH-35-6 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Langley/Empire RH-35-6, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Langley/Empire RH-35-6, that we can find in the current document
3. Tips how to use the basic functions of the device Langley/Empire RH-35-6 - which should help us in our first steps of using Langley/Empire RH-35-6
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Langley/Empire RH-35-6
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Langley/Empire RH-35-6 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Langley/Empire RH-35-6?

Use the form below

If you did not solve your problem by using a manual Langley/Empire RH-35-6, ask a question using the form below. If a user had a similar problem with Langley/Empire RH-35-6 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)