Hans Grohe 26396001 - page 1
ShowerArc 26396001 Installation Instructions / W arranty ...
-
Hans Grohe 26396001 - page 2
2 ShowerArc 26396001 Minimum ceiling height – 90 1/2” ...
-
Hans Grohe 26396001 - page 3
3 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber . Please read over these instructions thor- oughly before beginning installation. Make sure that you have all tools and sup- plies needed to complete the installation. Inspect the ShowerArc thoroughly for ship- ping damage before beginning insta ...
-
Hans Grohe 26396001 - page 4
4 Installation in 90º corner: Instructions begin on page 5 W all-to-wall installation Requires 26397000 installation kit (included): Instructions begin on page 13. Roughing-in The ShowerArc requires 1/2” NPT female fittings, recessed 3/8” behind the surface of the finished wall, for the hot and cold water supplies for the thermostatic mixing v ...
-
Hans Grohe 26396001 - page 5
5 Only one set of supplies is required – do not install two sets of supplies . Installation in 90º corner The thermostatic mixing valve may be installed on either wall. This diagram shows both possible positions for the installation. ...
-
Hans Grohe 26396001 - page 6
6 Installation in 90º Corner Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4 ...
-
Hans Grohe 26396001 - page 7
7 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8 ...
-
Hans Grohe 26396001 - page 8
8 Seal the wall ar ound the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 9 10 11 12 6 mm ...
-
Hans Grohe 26396001 - page 9
9 13 14 15 16 ...
-
Hans Grohe 26396001 - page 10
10 1 2 17 18 19 20 6 mm ...
-
Hans Grohe 26396001 - page 11
11 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 21 22 23 24 6 mm ...
-
Hans Grohe 26396001 - page 12
12 T urn to page 22 to continue the installation. Seal the wall ar ound the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 25 26 ...
-
Hans Grohe 26396001 - page 13
13 The thermostatic mixing valve may be installed on either wall. The diagram shows both possible positions for the installation. Only one set of supplies is required – do not install two sets of supplies . W all-to-W all Installation ...
-
Hans Grohe 26396001 - page 14
14 W all-to-W all Installation Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4 ...
-
Hans Grohe 26396001 - page 15
15 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8 ...
-
Hans Grohe 26396001 - page 16
16 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 1 2 6 mm 12 9 10 11 ...
-
Hans Grohe 26396001 - page 17
17 Install the 26397000 mounting set 13 14 15 16 ...
-
Hans Grohe 26396001 - page 18
18 XX 90 XX = 17 18 19 20 ...
-
Hans Grohe 26396001 - page 19
19 6 mm SW 3 mm M6x8 1 2 24 21 22 23 ...
-
Hans Grohe 26396001 - page 20
20 Install the 26397000 mounting set M6x60 1. 2. 3. SW 3 mm M6x8 25 26 27 6 mm 28 Seal the wall around the an- chors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 ...
-
Hans Grohe 26396001 - page 21
21 T urn to page 22 to continue the installation. SW 3 mm M6x8 29 ...
-
Hans Grohe 26396001 - page 22
22 Install the Cover , Escutcheon, and Handle Install the Showerhead and Handshower 2 1 ...
-
Hans Grohe 26396001 - page 23
23 Reset the High T emperature Limit Stop Loosen the handle screw with a 3 mm Allen wrench. Remove the retainer clip and stop ring from the stem. T urn the stop unit to the handshower position. T urn the temperature control stem until the output water is the desired high temperature -- usually 110º. KLICK 1 2 3 4 ...
-
Hans Grohe 26396001 - page 24
24 T urn the stop unit to the off position. Install the stop ring so that the tooth is against the stop. Install the clip. Install the handle. T ighten the handle screw with a 3 mm Allen wrench. KLICK SW 3 mm 5 6 7 ...
-
Hans Grohe 26396001 - page 25
25 Justify the Handle T urn the diver ter handle to the handshower position. T urn the temperature control knob until the output water is 100ºF . T urn the diver ter handle to the off position. Loosen the handle screw with a 3 mm Allen wrench. Remove the handle. Align the indexing mark on the temperature control knob with the 100º mark. Replace t ...
-
Hans Grohe 26396001 - page 26
26 User Instructions Using the Handshower T urn the function lever to until the desired spray mode has been obtained. T urn the temperature control knob to change the tem- perature. T urn it clockwise to make the water cooler , counter-clockwise to make the water warmer . When the knob is turned counter-clockwise to the 100º position it will stop. ...
-
Hans Grohe 26396001 - page 27
27 If necessar y , pour about 3/4” of a commercial scale remover , such as Lime-Away or CLR, into a shallow dish. Soak the spray face for the amount of time shown in the label instructions. Rinse the spray face with clear water . Reinstall the handshower . Flush the handshower for at least one minute before using. The handshower uses the Rubit™ ...
-
Hans Grohe 26396001 - page 28
28 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 17 25 ...
-
Hans Grohe 26396001 - page 29
29 1 wall flange 96768000 2 escutcheon 96767000 3 branch connection 97496000 4 branch connection 97497000 5 shower hose 28276000 6 handshower 28504001 7 handshower holder 28321000 8 body spray 97603000 9 showerhead 97195001 10 handle 25971000 11 shutoff unit with selector 97976000 12 escutcheon 97491000 13 thermostat car tridge 94282000 14 noise re ...
-
Hans Grohe 26396001 - page 30
30 Problem Possible Cause Solution Unit outputs both hot and cold water , but it does not mix not a product defect -- the hot and cold supplies are reversed correct the plumbing W ater temperature does not get hot enough high temperature limit stop not set correctly reset high temperature limit stop handle not justified justify the handle thermosta ...
-
Hans Grohe 26396001 - page 31
31 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY ...
-
Hans Grohe 26396001 - page 32
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No. 90404701 • Revised 12/2007 the product for use primarily for any other purpose, including, without limitation, a commercial purpose, this warranty extends only (i) for ...
Do you have a question concerning Hans Grohe 26396001?
Use the form below
If you did not solve your problem by using a manual Hans Grohe 26396001, ask a question using the form below. If a user had a similar problem with Hans Grohe 26396001 it is likely that he will want to share the way to solve it.