Manual York D*V

25 pages 5.28 mb
Download

Go to site of 25

Summary
  • York D*V - page 1

    D*V Model Air Cooled Self Contained Indoor Packaged Units 2-25 Tons Preliminary Application Data July 28, 2008 Page 1 ...

  • York D*V - page 2

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 95,000* Design CFM: 3,200 Energy Efficiency Ratio : 11.55 EER** Net Cooling Capacity [Btuh] : 92,000** Net Cooling CFM: 3,200 Refrigerant : R22 Charge : 8.75 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 8.67 [sq ft] ...

  • York D*V - page 3

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 4

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 90. 0 72. 0 97. 5 57. 3 106. 7 43. 8 86. 8 70. 6 94. 1 55. 9 102. 5 42. 2 300 0 80° F 91. 3 86. 7 98. 2 71. 6 107. 6 57. 8 88. 4 85. 8 94. 7 70. 2 103. 4 56. 2 85° F 96 ...

  • York D*V - page 5

    March 2008 DIMENSIONAL DATA DPV096 & DPV120 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA4 (308) 4 of 4 DPV096 AND DPV120 DIMENSIONAL DA T A Page 5 ...

  • York D*V - page 6

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 122,000* Design CFM: 4,000 Energy Efficiency Ratio : 10.60 EER** Net Cooling Capacity [Btuh] : 117,000** Net Cooling CFM: 3,600 Refrigerant : R22 Charge : 9.5 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 8.67 [sq ft ...

  • York D*V - page 7

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 8

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 10 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 115. 4 91. 5 124. 8 73. 0 134. 5 53. 8 111. 0 89. 6 120. 2 71. 1 129. 8 52. 2 360 0 80° F 116. 6 109. 7 125. 8 90. 9 136. 1 72. 4 112. 6 107. 8 120. 9 89. 0 131. ...

  • York D*V - page 9

    March 2008 DIMENSIONAL DATA DPV096 & DPV120 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA5 (308) 4 of 4 DPV096 AND DPV120 DIMENSIONAL DA T A Page 9 ...

  • York D*V - page 10

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 150,000* Design CFM: 4,800 Energy Efficiency Ratio : 10.65 EER** Net Cooling Capacity [Btuh] : 144,000** Net Cooling CFM: 4,800 Refrigerant : R22 Charge : 12.13 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 13.03 [sq ...

  • York D*V - page 11

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 12

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 12 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 140. 0 108. 7 151. 6 87. 4 167. 1 66. 6 135. 4 106. 7 146. 6 85. 3 160. 8 64. 5 430 0 80° F 145. 8 132. 3 152. 8 108. 0 168. 5 88. 6 139. 8 129. 4 147. 1 106. 0 1 ...

  • York D*V - page 13

    DPV144 DPV180 March 2008 DIMENSIONAL DATA DPV144 & DPV180 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA6 (308) 4 of 4 DPV0144 AND DPV180 DIMENSIONAL DA T A Page 13 ...

  • York D*V - page 14

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 186,000* Design CFM: 6,000 Energy Efficiency Ratio : 9.80 EER** Net Cooling Capacity [Btuh] : 178,000** Net Cooling CFM: 5,500 Refrigerant : R22 Charge : 13.83 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 13.03 [sq ...

  • York D*V - page 15

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 16

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 15 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 175. 4 138. 5 189. 7 110. 0 207. 4 82. 9 168. 8 135. 5 182. 8 107. 8 200. 6 81. 8 540 0 80° F 177. 1 165. 8 191. 0 137. 5 209. 1 111. 5 171. 2 163. 1 184. 0 134. ...

  • York D*V - page 17

    DPV144 DPV180 March 2008 DIMENSIONAL DATA DPV144 & DPV180 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA7 (308) 4 of 4 DPV144 AND DPV180 DIMENSIONAL DA T A Page 17 ...

  • York D*V - page 18

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 244,000* Design CFM: 8,000 Energy Efficiency Ratio : 10.10 EER** Net Cooling Capacity [Btuh] : 236,000** Net Cooling CFM: 6,800 Refrigerant : R22 Charge : 18.35 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 19.00 [sq ...

  • York D*V - page 19

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 20

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 20 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 230. 3 184. 1 248. 7 146. 4 269. 3 108. 2 221. 9 180. 3 239. 8 142. 7 258. 3 104. 3 720 0 80° F 233. 3 221. 4 250. 2 182. 6 270. 6 146. 3 223. 9 216. 6 241. 0 178 ...

  • York D*V - page 21

    March 2008 DIMENSIONAL DATA DPV240 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA8 (308) 4 of 4 DPV240 DIMENSIONAL DA T A Page 21 ...

  • York D*V - page 22

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 304,000* Design CFM: 10,000 Energy Efficiency Ratio : 9.60 EER** Net Cooling Capacity [Btuh] : 286,000** Net Cooling CFM: 8,800 Refrigerant : R22 Charge : 14.65 Lbs./ circuit Compre ss or No./Type: 3/Scrol l Refrigerant Circuits : 3 / Independent Evaporator Coil Face Area: 19.797 [s ...

  • York D*V - page 23

    DATE: DESCRIPTION: "DPV" SERIES VER Johnson Controls maintains a continuous product improvement policy, t he refore specifications are subject to change without noti ce. March 2008 MECHANICAL SPECIFICATIONS DPV300 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA9 (308) 2 of 4 TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS G ...

  • York D*V - page 24

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 25 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 285. 6 225. 4 308. 9 180. 1 339. 4 136. 0 275. 0 220. 8 297. 5 175. 4 325. 1 133. 6 900 0 80° F 291. 7 271. 6 311. 4 224. 0 342. 3 182. 2 281. 0 267. 2 299. 6 219 ...

  • York D*V - page 25

    March 2008 DIMENSIONAL DATA DPV300 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA9 (308) 4 of 4 DPV300 DIMENSIONAL DA T A Page 25 ...

Manufacturer York Category Air Conditioner

Documents that we receive from a manufacturer of a York D*V can be divided into several groups. They are, among others:
- York technical drawings
- D*V manuals
- York product data sheets
- information booklets
- or energy labels York D*V
All of them are important, but the most important information from the point of view of use of the device are in the user manual York D*V.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York D*V, service manual, brief instructions and user manuals York D*V. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York D*V.

Similar manuals

A complete manual for the device York D*V, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York D*V by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York D*V.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York D*V - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York D*V, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York D*V, that we can find in the current document
3. Tips how to use the basic functions of the device York D*V - which should help us in our first steps of using York D*V
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York D*V
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York D*V in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York D*V?

Use the form below

If you did not solve your problem by using a manual York D*V, ask a question using the form below. If a user had a similar problem with York D*V it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)