    LT-0229 (5/97) XR10/XR20 Command Processor Panels Installation Guide 10/26 Zone Burglary/Fire/Access Control Panels with Built-in Communicator 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 : http://www. guardianalarms . net ...

  • DMP Electronics LT-0229 (5 97) - page 2

    MODEL XR10/XR20 COMMAND PROCESSOR INST ALLA TION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and used properly in strict accordance with the manufacturer's instructions, may cause interference with radio and television reception. It has been type tested and found to comply with the limits for ...

  • DMP Electronics LT-0229 (5 97) - page 3

    TABLE OF CONTENTS Panel Specifications Power supply ........................................................................................ 1.1 Communication .................................................................................... 1.2 Panel zones ......................................................................................... ...

  • DMP Electronics LT-0229 (5 97) - page 4

    TABLE OF CONTENTS Section Reset Jumpers J16 Description ......................................................................................... 14.1 Universal UL Burglary Specifications Introduction ........................................................................................ 15.1 Wiring ................................................ ...

  • DMP Electronics LT-0229 (5 97) - page 5

    Page 1 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Panel Specifications 1.1 Power supply Transformer Input: 16.5 VAC 40VA (Models 320 wire-in or 321 plug-in) Standby Battery: 12 VDC 6.5Ah (40VA transformer charges up to 2 batteries) Auxiliary Output: 12 VDC at 500mA Bell Output: 12 VDC ...

  • DMP Electronics LT-0229 (5 97) - page 6

    Page 2 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 2.3 Before you begin Before installing the XR10/XR20, we recommend you read through the entire contents of this guide. Familiarize yourself with the features of the panel and the key points to remember during the installation. Be sure t ...

  • DMP Electronics LT-0229 (5 97) - page 7

    Page 3 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide System Components 3.1 Description The DMP XR10/XR20 system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer, and a 12 VDC 6.5 Ah battery. You can add up to four Security Command keypads to th ...

  • DMP Electronics LT-0229 (5 97) - page 8

    Page 4 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Installation 4.1 Mounting the enclosure The metal enclosure for the XR10/XR20 must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements. It is not necessary to remove the XR10/XR20 PC board ...

  • DMP Electronics LT-0229 (5 97) - page 9

    Page 5 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 4.2 Mounting keypads Security Command keypads have removable covers that allow you to easily mount the base with keypad circuit board to a wall or other flat surface using the screw holes provided on each corner. Before mounting the bas ...

  • DMP Electronics LT-0229 (5 97) - page 10

    Page 6 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 6.4 Discharge/recharge The XR10/XR20 battery charging circuit float charges at 13.9 VDC at a maximum current of 1.2 Amps using a 40VA transformer. The total current available is reduced by the combined auxiliary current draw from termin ...

  • DMP Electronics LT-0229 (5 97) - page 11

    Page 7 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Bell Output 7.1 Terminals 5 and 6 Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated for a maximum output of 1.5 Amps. This output can be steady or pulsed depending upon the Bell Act ...

  • DMP Electronics LT-0229 (5 97) - page 12

    Page 8 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 10.2 Operational parameters Each burglary protection zone detects three conditions: open, normal, and short. The parameters for each are listed below: Condition Resistance on zone Voltage on right terminal Open over 1300 ohms over 2.0 V ...

  • DMP Electronics LT-0229 (5 97) - page 13

    Page 9 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Annunciator Outputs 12.1 Description The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions occurring on the system. Annunciator outputs do not provide a voltage but instead switc ...

  • DMP Electronics LT-0229 (5 97) - page 14

    Page 10 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 13.4 Ground start To configure the XR10/XR20 for ground start operation, you must install the appropriate ground start module and program one of the panel's available annunciator outputs for Ground Start operation. Refer to the XR ...

  • DMP Electronics LT-0229 (5 97) - page 15

    Page 11 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide UNIVERSAL UL BURGLARY SPECIFICATIONS 15.1 Introduction The programming and installation specifications contained in this section must be completed when installing the XR10/XR20 panel in accordance with any of the UL burglary standards. ...

  • DMP Electronics LT-0229 (5 97) - page 16

    Page 12 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide UL 1610 and 1076 SPECIFICATIONS Central-Station and Proprietary Burglar-Alarm Units 17.1 Opening/Closing reports The Opening/Closing Reports option must be programmed as YES. See section 5.2 of the XR10 Programming Guide (LT-0230) and ...

  • DMP Electronics LT-0229 (5 97) - page 17

    Page 13 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 19.6 Mercantile Safe and Vault When the DMP Model 349A housing is used, the XR10/XR20 provides operation as a mercantile safe and vault alarm. Bell Supervision and wiring must be in accordance with UL 681. If the Model XR10/XR20 is mou ...

  • DMP Electronics LT-0229 (5 97) - page 18

    Page 14 Troubleshooting 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Installation Guide Problem Possible Cause Solution Security Command keypads display " SERVICE REQUIRED" J16 reset jumper is installed. Open or short on the green data wire to the keypad. Bad keypad or zone expander. Remove the J16 reset jumper. C ...

Manufacturer DMP Electronics Category Home Security System

Documents that we receive from a manufacturer of a DMP Electronics LT-0229 (5 97) can be divided into several groups. They are, among others:
- DMP Electronics technical drawings
- LT-0229 (5 97) manuals
- DMP Electronics product data sheets
- information booklets
- or energy labels DMP Electronics LT-0229 (5 97)
All of them are important, but the most important information from the point of view of use of the device are in the user manual DMP Electronics LT-0229 (5 97).

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals DMP Electronics LT-0229 (5 97), service manual, brief instructions and user manuals DMP Electronics LT-0229 (5 97). Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product DMP Electronics LT-0229 (5 97).

A complete manual for the device DMP Electronics LT-0229 (5 97), how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use DMP Electronics LT-0229 (5 97) by users. Manuals are usually written by a technical writer, but in a language understandable to all users of DMP Electronics LT-0229 (5 97).

A complete DMP Electronics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual DMP Electronics LT-0229 (5 97) - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the DMP Electronics LT-0229 (5 97), FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the DMP Electronics LT-0229 (5 97), that we can find in the current document
3. Tips how to use the basic functions of the device DMP Electronics LT-0229 (5 97) - which should help us in our first steps of using DMP Electronics LT-0229 (5 97)
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with DMP Electronics LT-0229 (5 97)
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of DMP Electronics LT-0229 (5 97) in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning DMP Electronics LT-0229 (5 97)?

Use the form below

If you did not solve your problem by using a manual DMP Electronics LT-0229 (5 97), ask a question using the form below. If a user had a similar problem with DMP Electronics LT-0229 (5 97) it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)