    Making quality of care easy Respiratory Care Solutions VP AP ™ ST NONINV ASIVE VENTILA TOR User Guide A English 368551.indb 1 4/02/2013 3:14:20 PM ...

  • ResMed VPAP ST - page 2

    Making quality of care easy Respiratory Care Solutions 368551.indb 2 4/02/2013 3:14:20 PM ...

  • ResMed VPAP ST - page 3

    English 1  English Indications for use The VPAP ST is indica ted to provide noninvas ive ventilation for pa tients weighing more than 13 kg or more than 30 kg in iVAPS mode with respirat ory insufficiency or ob structive sleep ap noea (OSA). The VPAP ST is intended for home a nd hospital u se. Contraindications Positive airwa y pressure therapy ...

  • ResMed VPAP ST - page 4

    2  Setup Refer to i llustration A. 1. Connect the DC pl ug of the power supply unit to the rear of the de vice. 2. Connect t he power cord to the power supply uni t. 3. Plug the othe r end of the po wer cord into the power outl et. 4. Connect o ne end of the air tubin g firmly onto the air outlet. 5. Connect t he assembled mask syste m to the fr ...

  • ResMed VPAP ST - page 5

    English 3  Notes:  If your cli nician has enabled Sma rtStart your device wil l start automatically wh en you breathe into the mask and stop autom atically when you remove the mask.  If power is i nterrupted during tre atment, the device aut omatically restarts t herapy when power is restor ed. Cleaning and maintena nce You should r egular ...

  • ResMed VPAP ST - page 6

    4  SD card An SD card ha s been supplied to ga ther therapy data from your device and provi de settings updates from your clini cian. When instructe d to do so, disconnect the device from th e power outlet, remove your SD card, i nsert it in the prot ective folder and s end it to your clinicia n. For more information on removing and i nserting y ...

  • ResMed VPAP ST - page 7

    English 5  Problem/Possible ca use Solution EPAP may b e set to o low. Talk to your cl inician a bout your settings. Device does n ot start when you b reathe into the mask Breath is not deep enough to trigger SmartS tart/Stop. Take a deep breat h in and out through th e mask. SmartStart/St op is disabled because Le ak Alert is en abled. Press St ...

  • ResMed VPAP ST - page 8

    6  Problem/Possible ca use Solution The patient i s using a paediatric mask with a set pressure less than 8 cm H 2 O. Disable SmartS tart/Stop. Pressure ri ses inappropriately Talking, cou ghing or breathing in an unusual manne r. Avoid talkin g with a nasal mask on, a nd breathe as normally a s possible. Mask cush ion is bu zzing aga inst the s ...

  • ResMed VPAP ST - page 9

    English 7  Problem/Possible ca use Solution Displays mes sage: No tube, please check your tube is connected Flow is high because air tu bing is no t connecte d prop erly. Note: The tube di sconnection check may not operate when an antibacterial filter is used. Connect the air tubing firmly at both ends. Displays mes sage: Tube blocked, please ch ...

  • ResMed VPAP ST - page 10

    8  General technical specifications Power supply 90W power supply unit Input range: 100– 240V, 50–60Hz, 115V, 400Hz nomin al for aircraft us e Typical power con sumption: 70W (80VA) Maximum power consumptio n: 110W (120VA) 30W power supply unit Input range: 100– 240V, 50–60Hz, 115V, 400Hz nomin al for aircraft us e Typical power con sump ...

  • ResMed VPAP ST - page 11

    English 9  VPAP ST technical specification s Mode pressure ranges CPAP mode Set Pressu re: 4–20 cm H 2 O S, ST, T and PAC modes IPAP: 4–25 cm H 2 O; EPAP: 2–25 cm H 2 O iVAPS mode PS: 0–23 cm H 2 O; EPAP: 2–25 cm H 2 O Maximum single fault pressu re Max imum single fa ult steady state press ure: 30 cm H 2 O—if pressur e exceeded for ...

  • ResMed VPAP ST - page 12

    10  Air tubing technical specifications Air tubing Material Length Inner diameter ClimateL ine heated ai r tubing Flexibl e plastic and el ectrical compone nts 2 m 15 mm ClimateLine MAX heated air tubing Flexibl e plastic and el ectrical compone nts 1.9 m 19 mm SlimLine air tu bing Flexible plastic 1.8 m 15 mm Standard air tubing Flexible pl ast ...

  • ResMed VPAP ST - page 13

    English 11  Humidifier performance The following sett ings have been tested at 22°C ambient tempe rature: Mask press ure cm H 2 O RH output % Nominal system output AH a , BTPS b Setting 3 Setting 6 Setting 3 Setting 6 3 90 100 10 18 10 95 100 11.5 21 20 95 100 11 18 25 100 100 12 13.5 a. AH - Absolute Humidity in mg/L. b. BTPS - Body Temperatur ...

  • ResMed VPAP ST - page 14

    12  Displayed values Value Range Display resolu tion Pressure sen sor at air outlet Mask pressu re 4-20 cm H 2 O (CPAP); 2- 25 cm H 2 O (S, ST, T, PAC, iVAPS) 0.1 cm H 2 O Flow derived values Leak 0 – 200 L/min 1 L/min Tidal volume 0 – 4000 mL 1 mL Respiratory ra te 0 – 50 BPM 1 BPM Minute ventilatio n 0 – 30 L/min 0.1 L/min Ti 0.1 – 4 ...

  • ResMed VPAP ST - page 15

    English 13  Pressure accuracy Maximum static pres sure variation at 10 cm H 2 O according to EN ISO 17510-1:20 09 Standard air tubing SlimLine air tubing Without H5i 9.89 cm H 2 O to 9.97 cm H 2 O 9.76 cm H 2 O to 9.87 cm H 2 O With H5i 9.82 cm H 2 O to 9.98 cm H 2 O 9.78 cm H 2 O to 9.88 cm H 2 O Maximum dynamic pr essure variation acco rding t ...

  • ResMed VPAP ST - page 16

    14  Direct curr ent; Lock/unloc k; China polluti on control logo 1; China pollution control logo 2; E uropean Authorised Representative; Not drip proof; Keep dry; Environmental informat ion WEEE 2002/96/EC is a European Dire ctive that requires the proper disposal of electrical and electron ic equipmen t. This devi ce should be disposed of separ ...

  • ResMed VPAP ST - page 17

    English 15  Product Warranty period  Clip-type finger puls e sensors  CPAP and bile vel device dat a modules  Oximeters and CPAP and bilevel device oximeter adapters  Humidifiers and h umidifier cleanable water tubs  Titration c ontrol devices 1 year  CPAP, bilevel and ventilation de vices (including externa l power supply uni ...

  • ResMed VPAP ST - page 18

    16  WARNINGS  Read the ent ire manual before u sing the device.  Use the device only as direc ted by your physician or h ealthcare provider .  Use the devi ce only for the int ended use as describ ed in this manual. Ad vice contained in t his manual should not supersede instru ctions given by th e prescribing physici an.  If you noti ...

  • ResMed VPAP ST - page 19

    English 17   Do not leave long lengt hs of air tubing around the top of yo ur bed. It could twist around your head or neck while you are sleepi ng.  Do not use electr ically conductive o r antistati c air tubings.  Do not us e the air tubing if there are any vis ible signs of dam age.  Only ResMed air tubing and access ories should b ...

  • ResMed VPAP ST - page 20

    Making quality of care easy Respiratory Care Solutions 368551.indb 3 4/02/2013 3:14:20 PM ...

  • ResMed VPAP ST - page 21

    Gl ob al l ea d er s in s l ee p an d r es p ir at or y me di ci ne w w w.resmed.com Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abingdon Oxfordshire OX144RY UK. See www .resmed.com for other ...

Manufacturer ResMed Category Oxygen Equipment

Documents that we receive from a manufacturer of a ResMed VPAP ST can be divided into several groups. They are, among others:
- ResMed technical drawings
- VPAP ST manuals
- ResMed product data sheets
- information booklets
- or energy labels ResMed VPAP ST
All of them are important, but the most important information from the point of view of use of the device are in the user manual ResMed VPAP ST.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ResMed VPAP ST, service manual, brief instructions and user manuals ResMed VPAP ST. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ResMed VPAP ST.

Similar manuals

A complete manual for the device ResMed VPAP ST, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ResMed VPAP ST by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ResMed VPAP ST.

A complete ResMed manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ResMed VPAP ST - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ResMed VPAP ST, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ResMed VPAP ST, that we can find in the current document
3. Tips how to use the basic functions of the device ResMed VPAP ST - which should help us in our first steps of using ResMed VPAP ST
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ResMed VPAP ST